메뉴 건너뛰기




Volumn 20, Issue 2, 1996, Pages 179-188

Ultrastructural study of the osteointegration of bioceramics (Whitlockite and composite β-TCP + collagen) in rabbit bone

Author keywords

Biomaterials; Composite TCP + C; Osteointegration; Ultrastructure; TCP

Indexed keywords

CALCIUM PHOSPHATE;

EID: 0029986373     PISSN: 01913123     EISSN: None     Source Type: Journal    
DOI: 10.3109/01913129609016313     Document Type: Article
Times cited : (15)

References (13)
  • 1
    • 0019993718 scopus 로고
    • Preparation and some properties of sintered β-whitlockite
    • Driessen AA, Klein CPTA, De Groot K. Preparation and some properties of sintered β-whitlockite. Biomaterials. 1982;3:113-115.
    • (1982) Biomaterials , vol.3 , pp. 113-115
    • Driessen, A.A.1    Klein, C.P.T.A.2    De Groot, K.3
  • 2
    • 0021966491 scopus 로고
    • Interaction of biodegradable β-whitlockite ceramics with bone tissue: An in vivo study
    • Klein CPTA, De Groot K, Driessen AA, Van Der Lubbe HBM. Interaction of biodegradable β-whitlockite ceramics with bone tissue: an in vivo study. Biomaterials. 1985;6: 189-192.
    • (1985) Biomaterials , vol.6 , pp. 189-192
    • Klein, C.1    De Groot, K.2    Driessen, A.A.3    Van Der Lubbe, H.B.M.4
  • 3
    • 0024229167 scopus 로고
    • Biomaterials and biomedical devices
    • Hanker JS, Giammara BL. Biomaterials and biomedical devices. Science. 1988;242:885-892.
    • (1988) Science , vol.242 , pp. 885-892
    • Hanker, J.S.1    Giammara, B.L.2
  • 4
    • 0026816690 scopus 로고
    • Differences in ceramic-bone interface between surface-active ceramics and resorbable ceramics: A study by scanning and transmission electron microscopy
    • Neo M, Kotani S, Fujita Y, et al. Differences in ceramic-bone interface between surface-active ceramics and resorbable ceramics: a study by scanning and transmission electron microscopy. J Biomed Mater Res. 1992;26:255-267.
    • (1992) J Biomed Mater Res. , vol.26 , pp. 255-267
    • Neo, M.1    Kotani, S.2    Fujita, Y.3
  • 6
    • 0027642518 scopus 로고
    • Apatite formation on three kinds of bioactive material at an early atage in vivo: A comparative study by transmission electron microscopy
    • Neo M, Nakamura T, Ohtsuki C, Kokubo T, Yamamuro T. Apatite formation on three kinds of bioactive material at an early atage in vivo: a comparative study by transmission electron microscopy. J Biomed Mater Res. 1993;27: 999-1006.
    • (1993) J Biomed Mater Res. , vol.27 , pp. 999-1006
    • Neo, M.1    Nakamura, T.2    Ohtsuki, C.3    Kokubo, T.4    Yamamuro, T.5
  • 7
    • 0018286218 scopus 로고
    • Synthesis and fabrication of β-tricalcium phosphate (Whitlockite) ceramics for potential prothetic applications
    • Jarcho M, Salsbury RL, Thomas MB, Doremus RH. Synthesis and fabrication of β-tricalcium phosphate (Whitlockite) ceramics for potential prothetic applications. J Mater Sci. 1979;14:142-150.
    • (1979) J Mater Sci. , vol.14 , pp. 142-150
    • Jarcho, M.1    Salsbury, R.L.2    Thomas, M.B.3    Doremus, R.H.4
  • 9
    • 0017365913 scopus 로고
    • Tissue, cellular and subcellular events at a bone-ceramics hydroxyapatite interface
    • Jarcho M, Kay JF, Gumaer KI, Doremus RH, Drobeck HP. Tissue, cellular and subcellular events at a bone-ceramics hydroxyapatite interface. J Bioeng. 1977;1:79-92.
    • (1977) J Bioeng , vol.1 , pp. 79-92
    • Jarcho, M.1    Kay, J.F.2    Gumaer, K.I.3    Doremus, R.H.4    Drobeck, H.P.5
  • 10
    • 0027591671 scopus 로고
    • Biocompatibility of tetracalcium phosphate cement when used as a bone substitute
    • Yoshimine Y, Akamine A, Mukai M, et al. Biocompatibility of tetracalcium phosphate cement when used as a bone substitute. Biomaterials. 1993;14:403-406.
    • (1993) Biomaterials , vol.14 , pp. 403-406
    • Yoshimine, Y.1    Akamine, A.2    Mukai, M.3
  • 11
    • 0028230087 scopus 로고
    • The influence of a hydroxyapatite and tricalcium phosphate coating on bone growth into titanium fiber-metal implants
    • Tisdel CL, Goldberg VM, Parr JA, Bensusan JS, Staikoff LS, Stevenson S. The influence of a hydroxyapatite and tricalcium phosphate coating on bone growth into titanium fiber-metal implants. J Bone Joint Surg Am. 1994; 76:159-171.
    • (1994) J Bone Joint Surg Am. , vol.76 , pp. 159-171
    • Tisdel, C.L.1    Goldberg, V.M.2    Parr, J.A.3    Bensusan, J.S.4    Staikoff, L.S.5    Stevenson, S.6
  • 12
    • 0021162959 scopus 로고
    • The use of ceramics for bone replacement: A comparative study of tree different porous ceramics
    • Uchida A, Nade S, McCartney E, Ching W. The use of ceramics for bone replacement: a comparative study of tree different porous ceramics. J Bone Joint Surg. 1984;2:269-275.
    • (1984) J Bone Joint Surg. , vol.2 , pp. 269-275
    • Uchida, A.1    Nade, S.2    McCartney, E.3    Ching, W.4
  • 13
    • 0023676513 scopus 로고
    • Effect of porosity and physicochemical properties on the stability, resorption and strength of calcium phosphate ceramics
    • DeGroot K. Effect of porosity and physicochemical properties on the stability, resorption and strength of calcium phosphate ceramics. Ann NY Acad Sci. 1988;523: 227-233.
    • (1988) Ann NY Acad Sci. , vol.523 , pp. 227-233
    • DeGroot, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.