메뉴 건너뛰기




Volumn 42, Issue 6 SUPPL., 1996, Pages 880-887

Linearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes

Author keywords

Electrolytes; Intermethod comparison

Indexed keywords

CALCIUM ION; MAGNESIUM ION;

EID: 0029979171     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.6.880     Document Type: Article
Times cited : (24)

References (12)
  • 1
    • 0022885504 scopus 로고
    • Ion-selective membrane electrodes for clinical use
    • Oesch U, Ammann D, Simon W. Ion-selective membrane electrodes for clinical use [Review]. Clin Chem 1986;32:1448-59.
    • (1986) Clin Chem , vol.32 , pp. 1448-1459
    • Oesch, U.1    Ammann, D.2    Simon, W.3
  • 2
    • 84986406921 scopus 로고
    • Cyclic octa- and decapeptides as ionophores for magnesium
    • Behm F, Ammann D, Simon W. Cyclic octa- and decapeptides as ionophores for magnesium. Helv Chim Acta 1985;68:110-8.
    • (1985) Helv Chim Acta , vol.68 , pp. 110-118
    • Behm, F.1    Ammann, D.2    Simon, W.3
  • 3
    • 0025319017 scopus 로고
    • Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum
    • Rouilly M, Rusterholz B, Spichiger UE, Simon W. Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum. Clin Chem 1990;36:466-9.
    • (1990) Clin Chem , vol.36 , pp. 466-469
    • Rouilly, M.1    Rusterholz, B.2    Spichiger, U.E.3    Simon, W.4
  • 4
    • 0028174757 scopus 로고
    • Analytical evaluation of Kone Microlyte determination of ionized magnesium
    • van Ingen HE, Huijgen HJ, Kok WT, Sanders TB. Analytical evaluation of Kone Microlyte determination of ionized magnesium. Clin Chem 1994;40:52-5.
    • (1994) Clin Chem , vol.40 , pp. 52-55
    • Van Ingen, H.E.1    Huijgen, H.J.2    Kok, W.T.3    Sanders, T.B.4
  • 6
    • 0028022728 scopus 로고
    • Measurement of ionized magnesium with neutral carrier based ISE's. Progress and results with the AVL 988-4 magnesium analyzer
    • Marsoner HJ, Spichiger UE, Ritter C, Sachs C, Ghahramani M, Offenbacher H, et al. Measurement of ionized magnesium with neutral carrier based ISE's. Progress and results with the AVL 988-4 magnesium analyzer. Scand J Clin Lab Invest 1994;54: 45-51.
    • (1994) Scand J Clin Lab Invest , vol.54 , pp. 45-51
    • Marsoner, H.J.1    Spichiger, U.E.2    Ritter, C.3    Sachs, C.4    Ghahramani, M.5    Offenbacher, H.6
  • 7
    • 4243548870 scopus 로고
    • Measurement of ionized magnesium with an ion selective electrode
    • Aizawa M, Kuwa K, eds. Methodology and clinical applications of pH, blood gases, electrolytes and sensor technology Tokyo, Japan: Gene Act Planning Corp.
    • Sachs C, Ritter C, Puaud M, Kindermans C, Spichiger UE, Marsoner HJ. Measurement of ionized magnesium with an ion selective electrode. In: Aizawa M, Kuwa K, eds. Methodology and clinical applications of pH, blood gases, electrolytes and sensor technology (Proceedings of the IFCC/WGISE-JSCC/CDGE Symposium, Hakone, Japan, 1991). Tokyo, Japan: Gene Act Planning Corp., 1992:13:177-81.
    • (1992) Proceedings of the IFCC/WGISE-JSCC/CDGE Symposium, Hakone, Japan, 1991 , vol.13 , pp. 177-181
    • Sachs, C.1    Ritter, C.2    Puaud, M.3    Kindermans, C.4    Spichiger, U.E.5    Marsoner, H.J.6
  • 8
    • 0342672454 scopus 로고
    • Determination and significance of ionized magnesium
    • Lewenstam A, Blomqvist N, Ost J. Determination and significance of ionized magnesium. Klin Lab 1993;2a:60-3.
    • (1993) Klin Lab , vol.2 A , pp. 60-63
    • Lewenstam, A.1    Blomqvist, N.2    Ost, J.3
  • 10
    • 0027479828 scopus 로고
    • A theoretical evaluation of linearity
    • Kroll MH, Emancipator K. A theoretical evaluation of linearity. Clin Chem 1993;39:405-13.
    • (1993) Clin Chem , vol.39 , pp. 405-413
    • Kroll, M.H.1    Emancipator, K.2
  • 11
    • 0027298239 scopus 로고
    • A quantitative measure of nonlinearity
    • Emancipator K, Kroll MH. A quantitative measure of nonlinearity. Clin Chem 1993;39:766-72.
    • (1993) Clin Chem , vol.39 , pp. 766-772
    • Emancipator, K.1    Kroll, M.H.2
  • 12
    • 14644423081 scopus 로고
    • NOVA 8, NOVA 8+ analyzer comparison for ionized calcium, normalized calcium and pH
    • Cecco SA, Rehak NN. NOVA 8, NOVA 8+ analyzer comparison for ionized calcium, normalized calcium and pH [Abstract]. Clin Chem 1994;40:1097-8.
    • (1994) Clin Chem , vol.40 , pp. 1097-1098
    • Cecco, S.A.1    Rehak, N.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.