메뉴 건너뛰기




Volumn 4, Issue 4, 1996, Pages 199-210

Optimization of HPLC separation by computer-assisted optimization methods comparison of three methods

Author keywords

Computer assisted methods; Optimization; Reversed phase HPLC

Indexed keywords

BIOGENIC AMINE;

EID: 0029969930     PISSN: 09280987     EISSN: None     Source Type: Journal    
DOI: 10.1016/0928-0987(95)00040-2     Document Type: Article
Times cited : (9)

References (23)
  • 2
    • 0026611287 scopus 로고
    • Computer simulation as a tool for the rapid optimization of the high-performance liquid chromatographic separation of a tryptic digest of human growth hormone
    • Chloupek, R.C., Hancock, W.S. and Snyder, L.R. (1992) Computer simulation as a tool for the rapid optimization of the high-performance liquid Chromatographic separation of a tryptic digest of human growth hormone. J. Chromatogr. 594, 65-73.
    • (1992) J. Chromatogr. , vol.594 , pp. 65-73
    • Chloupek, R.C.1    Hancock, W.S.2    Snyder, L.R.3
  • 3
    • 0040306888 scopus 로고
    • HPLC method development through retention prediction using structural data
    • Csokan, P.P., Darvas, F., Csizmadia, F. and Valkó, K. (1993) HPLC method development through retention prediction using structural data. LC·GC Int. 6, 361-369.
    • (1993) LC·GC Int. , vol.6 , pp. 361-369
    • Csokan, P.P.1    Darvas, F.2    Csizmadia, F.3    Valkó, K.4
  • 4
    • 0025772704 scopus 로고
    • Multiple-criteria optimization
    • Deming, S.N. (1991) Multiple-criteria optimization. J. Chromatogr. 550, 15-25.
    • (1991) J. Chromatogr. , vol.550 , pp. 15-25
    • Deming, S.N.1
  • 5
    • 0024854812 scopus 로고
    • DryLab computer simulation for high-performance liquid chromatographic method development
    • Dolan, J.W., Lommen, D.C. and Snyder, L.R. (1989) DryLab computer simulation for high-performance liquid Chromatographic method development. J. Chromatogr. 485, 91-112.
    • (1989) J. Chromatogr. , vol.485 , pp. 91-112
    • Dolan, J.W.1    Lommen, D.C.2    Snyder, L.R.3
  • 8
    • 85022961685 scopus 로고
    • Optimization of solvent strength and selectivity for reversed-phase liquid chromatography using an interactive mixture-design statistical technique
    • Gljach, J.L., Kirkland, J.J., Squire, K.M. and Minor, J.M. (1980) Optimization of solvent strength and selectivity for reversed-phase liquid chromatography using an interactive mixture-design statistical technique. J. Chromatogr. 199, 57-59.
    • (1980) J. Chromatogr. , vol.199 , pp. 57-59
    • Gljach, J.L.1    Kirkland, J.J.2    Squire, K.M.3    Minor, J.M.4
  • 10
    • 84983928254 scopus 로고
    • Combined effects of pH and surface-active-ion concentration in reversed-phase liquid chromatography
    • Kong, R.C., Sachok, B. and Deming, S.N. (1980) Combined effects of pH and surface-active-ion concentration in reversed-phase liquid chromatography. J. Chromatogr. 199, 307-316.
    • (1980) J. Chromatogr. , vol.199 , pp. 307-316
    • Kong, R.C.1    Sachok, B.2    Deming, S.N.3
  • 11
    • 0025668470 scopus 로고
    • Computer simulation for optimization of high-performance liquid chromatography of some phenolic pollutants
    • Markowski, W., Dzido, T.H. and Soczewinski, E. (1990) Computer simulation for optimization of high-performance liquid chromatography of some phenolic pollutants. J. Chromatogr. 523, 81-89.
    • (1990) J. Chromatogr. , vol.523 , pp. 81-89
    • Markowski, W.1    Dzido, T.H.2    Soczewinski, E.3
  • 13
    • 84954857365 scopus 로고
    • Correlation and prediction of the k′ values for mobile phase optimization in HPLC
    • Nyiredy, Sz., Dallenbach-Tölke, K. and Sticher, O. (1989) Correlation and prediction of the k′ values for mobile phase optimization in HPLC. J. Liq. Chromatogr. 12, 95-116.
    • (1989) J. Liq. Chromatogr. , vol.12 , pp. 95-116
    • Nyiredy, Sz.1    Dallenbach-Tölke, K.2    Sticher, O.3
  • 14
    • 0026010656 scopus 로고
    • "PRISMA" model for computer-aided HPLC mobile phase optimization based on an automatic peak identification approach
    • Nyiredy, Sz., Wosniok, W., Thiele, H and Sticher, O. (1991) "PRISMA" model for computer-aided HPLC mobile phase optimization based on an automatic peak identification approach. J. Liq. Chromatogr. 14, 3077-3110.
    • (1991) J. Liq. Chromatogr. , vol.14 , pp. 3077-3110
    • Nyiredy, Sz.1    Wosniok, W.2    Thiele, H.3    Sticher, O.4
  • 17
    • 0017982611 scopus 로고
    • Classification of the solvent properties of common liquids
    • Snyder, L.R. (1978) Classification of the solvent properties of common liquids. J. Chromatogr. Sci. 16, 223-234.
    • (1978) J. Chromatogr. Sci. , vol.16 , pp. 223-234
    • Snyder, L.R.1
  • 18
    • 0024804093 scopus 로고
    • DryLab® computer simulation for high-performance liquid chromatographic method development
    • Snyder, L.R., Dolan, J.W. and Lommen, D.C. (1989) DryLab® computer simulation for high-performance liquid Chromatographic method development. J. Chromatogr. 485, 65-89.
    • (1989) J. Chromatogr. , vol.485 , pp. 65-89
    • Snyder, L.R.1    Dolan, J.W.2    Lommen, D.C.3
  • 19
    • 0025799731 scopus 로고
    • Prediction of initial high-performance liquid chromatographic conditions for selectivity optimization in pharmaceutical analysis by an expert system approach
    • Szepesi, G. and Valkó, K. (1991) Prediction of initial high-performance liquid Chromatographic conditions for selectivity optimization in pharmaceutical analysis by an expert system approach. J. Chromatogr. 550, 87-100.
    • (1991) J. Chromatogr. , vol.550 , pp. 87-100
    • Szepesi, G.1    Valkó, K.2
  • 20
    • 0021124186 scopus 로고
    • General approach for the estimation of octanol/water partition coefficient by reversed-phase high-performance liquid chromatography
    • Valkó, K. (1984) General approach for the estimation of octanol/water partition coefficient by reversed-phase high-performance liquid chromatography. J. Liq. Chromatogr. 7, 1405-1424.
    • (1984) J. Liq. Chromatogr. , vol.7 , pp. 1405-1424
    • Valkó, K.1
  • 21
    • 0027402651 scopus 로고
    • 0) based on the slope and the intercept of the log k′ versus organic phase concentration plot
    • 0) based on the slope and the intercept of the log k′ versus organic phase concentration plot. J. Chromatogr. 631, 49-61.
    • (1993) J. Chromatogr. , vol.631 , pp. 49-61
    • Valkó, K.1    Slégel, P.2
  • 22
    • 0018519360 scopus 로고
    • Simplex algorithm for the optimization of gradient elution high-performance liquid chromatography
    • Watson, M.W. and Carr, P.W. (1979) Simplex algorithm for the optimization of gradient elution high-performance liquid chromatography. Anal. Chem. 51, 1835-1842.
    • (1979) Anal. Chem. , vol.51 , pp. 1835-1842
    • Watson, M.W.1    Carr, P.W.2
  • 23
    • 0027441401 scopus 로고
    • Use of computer simulations in the development of gradient and isocratic high-performance liquid chromatography methods for analysis of drug compounds and synthetic intermediates
    • Wrisley, L. (1993) Use of computer simulations in the development of gradient and isocratic high-performance liquid chromatography methods for analysis of drug compounds and synthetic intermediates. J. Chromatogr. 628, 191-198.
    • (1993) J. Chromatogr. , vol.628 , pp. 191-198
    • Wrisley, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.