메뉴 건너뛰기




Volumn 19, Issue 11 II, 1996, Pages 1786-1790

Exercise induced sympathetic influences do not change interatrial conduction times in VDD and DDD pacing

Author keywords

AV delay; dual chamber pacing; interatrial conduction

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; ELECTROGRAPHY; EXERCISE; FEMALE; HEART ATRIUM CONDUCTION; HEART ATRIUM PACING; HEMODYNAMICS; HUMAN; MALE; PACEMAKER ELECTRODE; SENSOR; SYMPATHETIC TONE; TELEMETRY;

EID: 0029969058     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03225.x     Document Type: Article
Times cited : (21)

References (9)
  • 1
    • 0000537120 scopus 로고
    • AV delay optimization in DDD and DDDR pacing
    • Barold SS, Mugica J (eds.): Mount Kisco, NY, Futura Publishing Company
    • Daubert C, Ritter P, Mabo P, et al. AV delay optimization in DDD and DDDR pacing. In Barold SS, Mugica J (eds.): New Perspectives in Cardiac Pacing. Volume 3. Mount Kisco, NY, Futura Publishing Company, 1993, pp. 259-287.
    • (1993) New Perspectives in Cardiac Pacing , vol.3 , pp. 259-287
    • Daubert, C.1    Ritter, P.2    Mabo, P.3
  • 2
    • 0022979176 scopus 로고
    • Interatrial conduction during cardiac pacing
    • Ausubel K, Klementowicz P, Furman S. Interatrial conduction during cardiac pacing. PACE 1986; 9: 1026-1031.
    • (1986) PACE , vol.9 , pp. 1026-1031
    • Ausubel, K.1    Klementowicz, P.2    Furman, S.3
  • 3
    • 0023230352 scopus 로고
    • Importance of left atrial timing in the programming of dual-chamber pacemakers
    • Wish M, Fletcher RD, Gottdiener JS, et al. Importance of left atrial timing in the programming of dual-chamber pacemakers. Am J Cardiol 1987; 60: 566-571.
    • (1987) Am J Cardiol , vol.60 , pp. 566-571
    • Wish, M.1    Fletcher, R.D.2    Gottdiener, J.S.3
  • 4
    • 0345121811 scopus 로고
    • Left heart function during right heart pacing
    • Chirife R. Left heart function during right heart pacing. PACE 1994; 17:1451-1455.
    • (1994) PACE , vol.17 , pp. 1451-1455
    • Chirife, R.1
  • 5
    • 0023692741 scopus 로고
    • M-mode echocardiograms for determination of optimal left atrial timing in patients with dual chamber pacemakers
    • Wish M, Gottdiener JS, Cohen AI, et al. M-mode echocardiograms for determination of optimal left atrial timing in patients with dual chamber pacemakers. Am J Cardiol 1988; 61:317-322.
    • (1988) Am J Cardiol , vol.61 , pp. 317-322
    • Wish, M.1    Gottdiener, J.S.2    Cohen, A.I.3
  • 6
    • 10544226924 scopus 로고
    • AV delay after atrial sensing and atrial stimulation in DDD pacemakers - Is a standardized difference justified?
    • von Knorre GH, Ismer B, Voss W. AV delay after atrial sensing and atrial stimulation in DDD pacemakers - is a standardized difference justified? (abstract) PACE 1994; 17:804.
    • (1994) PACE , vol.17 , pp. 804
    • Von Knorre, G.H.1    Ismer, B.2    Voss, W.3
  • 7
    • 84910349402 scopus 로고
    • Intracardiac ECG from pacemaker telemetry
    • Gòmez FP [ed.: Mount Kisco, NY, Futura Media Services
    • van Hove JWJ, Kleiss B, Slagmolen PJM, et al. Intracardiac ECG from pacemaker telemetry. In Gòmez FP [ed.): Cardiac Pacing. Mount Kisco, NY, Futura Media Services, 1985, pp. 1120-1124.
    • (1985) Cardiac Pacing , pp. 1120-1124
    • Van Hove, J.W.J.1    Kleiss, B.2    Slagmolen, P.J.M.3
  • 8
    • 0015304890 scopus 로고
    • Filtered bipolar esophageal electrocardiography
    • Barold SS. Filtered bipolar esophageal electrocardiography. Am Heart J 1972; 83:431.
    • (1972) Am Heart J , vol.83 , pp. 431
    • Barold, S.S.1
  • 9
    • 0022644495 scopus 로고
    • In vivo validation of the origin of the esophageal electrocardiogram
    • Binkley PF, Bush CA, Fleishman BL, et al. In vivo validation of the origin of the esophageal electrocardiogram. J Am Coll Cardiol 1986; 7:813-818.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 813-818
    • Binkley, P.F.1    Bush, C.A.2    Fleishman, B.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.