-
1
-
-
0022551118
-
Arterial isoflurane concentration and EEG burst suppression during cardiopulmonary bypass
-
Loomis CW Brunet D Milne B Arterial isoflurane concentration and EEG burst suppression during cardiopulmonary bypass Clin Pharmacol Ther 40 1986 304 313
-
(1986)
Clin Pharmacol Ther
, vol.40
, pp. 304-313
-
-
Loomis, CW1
Brunet, D2
Milne, B3
-
2
-
-
0020699859
-
Comparison of isoflurane and halothane when used to control intra-operative hypertension in patients undergoing coronary artery bypass surgery
-
Hess W Arnold B Schulte-Sasse U Comparison of isoflurane and halothane when used to control intra-operative hypertension in patients undergoing coronary artery bypass surgery Anesth Analg 62 1983 15 20
-
(1983)
Anesth Analg
, vol.62
, pp. 15-20
-
-
Hess, W1
Arnold, B2
Schulte-Sasse, U3
-
3
-
-
0024244121
-
Isoflurane elimination via a bubble oxygenator during extracorporeal circulation
-
Price SL Brown DL Carpenter RL Isoflurane elimination via a bubble oxygenator during extracorporeal circulation J Cardiothorac Anesth 2 1988 41 44
-
(1988)
J Cardiothorac Anesth
, vol.2
, pp. 41-44
-
-
Price, SL1
Brown, DL2
Carpenter, RL3
-
4
-
-
0023809558
-
In vitro anesthetic washin and washout via bubble oxygenators: influence of anesthetic solubility and rates of carrier gas inflow and pump blood flow
-
Nussmeier NA Moskowitz GJ Weiskopf RB In vitro anesthetic washin and washout via bubble oxygenators: influence of anesthetic solubility and rates of carrier gas inflow and pump blood flow Anesth Analg 67 1988 982 987
-
(1988)
Anesth Analg
, vol.67
, pp. 982-987
-
-
Nussmeier, NA1
Moskowitz, GJ2
Weiskopf, RB3
-
5
-
-
0024470268
-
Washin and washout of isoflurane administered via bubble oxygenators during hypothermic cardiopulmonary bypass
-
Nussmeier NA Lambert ML Moskowitz GJ Washin and washout of isoflurane administered via bubble oxygenators during hypothermic cardiopulmonary bypass Anesthesiology 71 1989 519 525
-
(1989)
Anesthesiology
, vol.71
, pp. 519-525
-
-
Nussmeier, NA1
Lambert, ML2
Moskowitz, GJ3
-
6
-
-
0024799225
-
Isoflurane uptake and elimination are delayed by absorption of anesthetic by the SciMed membrane oxygenator
-
Stern RC Weiss CI Steinbach JH Isoflurane uptake and elimination are delayed by absorption of anesthetic by the SciMed membrane oxygenator Anesth Analg 69 1989 657 662
-
(1989)
Anesth Analg
, vol.69
, pp. 657-662
-
-
Stern, RC1
Weiss, CI2
Steinbach, JH3
-
7
-
-
0015132132
-
Determination of halothane in gas, blood and tissues by chemical extraction and gas chromatography
-
Allott PR Steward A Mapleson WW Determination of halothane in gas, blood and tissues by chemical extraction and gas chromatography Br J Anaesth 43 1971 913 918
-
(1971)
Br J Anaesth
, vol.43
, pp. 913-918
-
-
Allott, PR1
Steward, A2
Mapleson, WW3
-
8
-
-
0025371959
-
In vitro variability in fentanyl absorption by different membrane oxygenators
-
Rosen DA Rosen KR Silvasi DL In vitro variability in fentanyl absorption by different membrane oxygenators J Cardiothorac Anesth 4 1990 332 335
-
(1990)
J Cardiothorac Anesth
, vol.4
, pp. 332-335
-
-
Rosen, DA1
Rosen, KR2
Silvasi, DL3
-
9
-
-
0028336709
-
Membrane oxygenators: Influence of design on performance
-
Gaylor JDS Hickey S Bell G Membrane oxygenators: Influence of design on performance Perfusion 9 1994 173 180
-
(1994)
Perfusion
, vol.9
, pp. 173-180
-
-
Gaylor, JDS1
Hickey, S2
Bell, G3
|