메뉴 건너뛰기




Volumn 35, Issue 6, 1996, Pages 895-902

Fast interleaved echo-planar imaging with navigator: High resolution anatomic and functional images at 4 tesla

Author keywords

Echo planar imaging; functional MRI; high resolution imaging; navigator

Indexed keywords

BIOMAGNETISM; ELECTROMAGNETIC FIELD EFFECTS; SIGNAL TO NOISE RATIO;

EID: 0029954899     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910350618     Document Type: Article
Times cited : (80)

References (30)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • P. Mansfield, Multi-planar image formation using NMR spin echoes. J. Phys. C: Solid State Phys. 10, L55 (1977).
    • (1977) J. Phys. C: Solid State Phys. , vol.10
    • Mansfield, P.1
  • 2
    • 0025991499 scopus 로고
    • Echo-planar imaging: Magnetic resonance imaging in a fraction of a second
    • M. K. Stehling, R. Turner, P. Mansfield, Echo-planar imaging: magnetic resonance imaging in a fraction of a second. Science 254, 43-50 (1991).
    • (1991) Science , vol.254 , pp. 43-50
    • Stehling, M.K.1    Turner, R.2    Mansfield, P.3
  • 3
    • 0025298010 scopus 로고
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn. Reson. Med. 14, 123-139 (1990).
    • (1990) Magn. Reson. Med. , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 7
    • 0028100297 scopus 로고
    • Activation of a cerebellar output nucleus during cognitive processing
    • S.-G. Kim, K. Ugurbil, P. L. Strick, Activation of a cerebellar output nucleus during cognitive processing. Science 265, 949-951 (1994).
    • (1994) Science , vol.265 , pp. 949-951
    • Kim, S.-G.1    Ugurbil, K.2    Strick, P.L.3
  • 10
    • 0027513370 scopus 로고
    • Functional mapping of the human visual cortex at 4 and 1.5 Tesla using deoxygenation contrast EPI
    • R. Turner, P. Jezzard, H. Wen, K. K. Kwong, D. Le Bihan, T. Zeffiro, R. Balaban, Functional mapping of the human visual cortex at 4 and 1.5 Tesla using deoxygenation contrast EPI. Magn. Reson. Med. 29, 277-279 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 277-279
    • Turner, R.1    Jezzard, P.2    Wen, H.3    Kwong, K.K.4    Le Bihan, D.5    Zeffiro, T.6    Balaban, R.7
  • 12
    • 0027499838 scopus 로고
    • Functional MRI of human brain activation at high spatial resolution
    • J. Frahm, K. D. Merboldt, W. Hanicke, Functional MRI of human brain activation at high spatial resolution. Magn. Reson. Med. 29, 139-144 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 139-144
    • Frahm, J.1    Merboldt, K.D.2    Hanicke, W.3
  • 13
    • 0027375577 scopus 로고
    • Ultiafast interleaved gradient-echo-planar imaging on a standard scanner
    • G. C. McKinnon, Ultiafast interleaved gradient-echo-planar imaging on a standard scanner. Magn. Reson. Med. 30, 609-616 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 609-616
    • McKinnon, G.C.1
  • 18
    • 6844236323 scopus 로고
    • Excitation angle optimization for snapshot FLASH and a signal comparison with EPI
    • D. G. Norris, Excitation angle optimization for snapshot FLASH and a signal comparison with EPI. J. Magn. Reson. 91, 190-193 (1991).
    • (1991) J. Magn. Reson. , vol.91 , pp. 190-193
    • Norris, D.G.1
  • 19
    • 0028285121 scopus 로고
    • Reduction of signal fluctuation in functional MRI using navigator echoes
    • X. Hu, S.-G. Kim, Reduction of signal fluctuation in functional MRI using navigator echoes. Magn. Reson. Med. 31, 495-503 (1993).
    • (1993) Magn. Reson. Med. , vol.31 , pp. 495-503
    • Hu, X.1    Kim, S.-G.2
  • 20
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • R. L. Ehman, J. P. Felmlee, Adaptive technique for high-definition MR imaging of moving structures. Radiology 173, 255-263 (1989).
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 21
    • 0026247679 scopus 로고
    • Theoretical aspects of motion sensitivity and compensation in echo-planar imaging
    • J. L. Duerk, O. P. Simonetti, Theoretical aspects of motion sensitivity and compensation in echo-planar imaging. J. Magn. Reson. Imaging 1, 643-650 (1991).
    • (1991) J. Magn. Reson. Imaging , vol.1 , pp. 643-650
    • Duerk, J.L.1    Simonetti, O.P.2
  • 22
    • 0026856564 scopus 로고
    • Analysis of flow effects in echo-planar imaging
    • K. Butts, S. J. Riederer, Analysis of flow effects in echo-planar imaging. J. Magn. Reson. Imaging 2, 285-293 (1992).
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 285-293
    • Butts, K.1    Riederer, S.J.2
  • 25
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with nonequivalent k-space sampling
    • H. Bruder, H. Fischer, H.-E. Reinfelder, F. Schmitt, Image reconstruction for echo planar imaging with nonequivalent k-space sampling. Magn. Reson. Med. 23, 311-323 (1992).
    • (1992) Magn. Reson. Med. , vol.23 , pp. 311-323
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.-E.3    Schmitt, F.4
  • 26
    • 0028411971 scopus 로고
    • 1 determination from inversion recovery images: Application to human brain at 4 Tesla
    • 1 determination from inversion recovery images: application to human brain at 4 Tesla. Magn. Reson. Med. 31, 445-449 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 445-449
    • Kim, S.-G.1    Hu, X.2    Ugurbil, K.3
  • 27
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MRI of the human brain
    • P. A. Bandettini, A. Jesmanowicz, E. C. Wong, J. S. Hyde, Processing strategies for time-course data sets in functional MRI of the human brain. Magn. Reson. Med. 30, 161-173 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4
  • 29
    • 0029118783 scopus 로고
    • Retrospective estimation and compensation of physiological fluctuation in functional MRI
    • X. Hu, T. H. Le, T. Parrish, P. Erhard, Retrospective estimation and compensation of physiological fluctuation in functional MRI. Magn. Reson. Med. 34, 210-221 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 210-221
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.