메뉴 건너뛰기




Volumn 105, Issue 6, 1996, Pages 782-787

Estimation of the lower limits of manual and automated platelet counting

Author keywords

Limit of detection; Lower limit of quantification; Measuring interval; Platelet count; Power of definition

Indexed keywords

ARTICLE; AUTOANALYSIS; COMPARATIVE STUDY; DIAGNOSTIC ACCURACY; HUMAN; HUMAN CELL; LABORATORY TEST; PRIORITY JOURNAL; THROMBOCYTE COUNT;

EID: 0029951954     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1093/ajcp/105.6.782     Document Type: Article
Times cited : (20)

References (24)
  • 1
    • 0002156170 scopus 로고
    • Examination of blood
    • Williams WJ, Beutler E, Ersley AJ, Lichtman MA, eds. New York, NY: McGraw-Hill
    • Williams WJ, Nelson DA, Morris MW. Examination of blood. In: Williams WJ, Beutler E, Ersley AJ, Lichtman MA, eds. Hematology. ed 4. New York, NY: McGraw-Hill, 1990.
    • (1990) Hematology. Ed 4
    • Williams, W.J.1    Nelson, D.A.2    Morris, M.W.3
  • 3
    • 0027131596 scopus 로고
    • A parallel evaluation of four automated hematology analyzers
    • Bentley SA, Johnson A, Bishop CA. A parallel evaluation of four automated hematology analyzers. Am J Clin Pathol 1993;100: 626-632.
    • (1993) Am J Clin Pathol , vol.100 , pp. 626-632
    • Bentley, S.A.1    Johnson, A.2    Bishop, C.A.3
  • 4
    • 0007849188 scopus 로고
    • Principles of hematologic examination
    • Lee GR, Bithell TC, Foerster J, et al, eds. Philadelphia: Lea and Febiger
    • Kjeldsberg CR. Principles of hematologic examination. In: Lee GR, Bithell TC, Foerster J, et al, eds. Wintrobe's Clinical Hematology. ed 9. vol 1. Philadelphia: Lea and Febiger, 1993, pp 11-12.
    • (1993) Wintrobe's Clinical Hematology. Ed 9 , vol.1 , pp. 11-12
    • Kjeldsberg, C.R.1
  • 6
    • 0019304541 scopus 로고
    • Automated platelet counters: A comparative evaluation of latest instrumentation
    • Mayer K, Chin B, Magnes J, et al. Automated platelet counters: A comparative evaluation of latest instrumentation. Am J Clin Pathol 1980;74:135-150.
    • (1980) Am J Clin Pathol , vol.74 , pp. 135-150
    • Mayer, K.1    Chin, B.2    Magnes, J.3
  • 8
    • 0018961361 scopus 로고
    • Automated platelet counts: Accuracy, Precision, Range
    • Ross DW, Ayscue L, Gulley M. Automated platelet counts: Accuracy, Precision, Range. Am J Clin Palhol 1980;74:151-156.
    • (1980) Am J Clin Palhol , vol.74 , pp. 151-156
    • Ross, D.W.1    Ayscue, L.2    Gulley, M.3
  • 9
    • 0022448564 scopus 로고
    • Need for improved instrument and kit evaluations
    • Hackney JR, Cembrowski GS. Need for improved instrument and kit evaluations. Am J Clin Pathol 1986;86:391-393.
    • (1986) Am J Clin Pathol , vol.86 , pp. 391-393
    • Hackney, J.R.1    Cembrowski, G.S.2
  • 10
    • 84946378686 scopus 로고
    • A new look at the limits of detection (LD). quantification (LQ) and power of definition (PD)
    • Gautschi K, Keller B, Keller H, et al. A new look at the limits of detection (LD). quantification (LQ) and power of definition (PD). Eur J Clin Chem Clin Biochem 1993;31:433-440.
    • (1993) Eur J Clin Chem Clin Biochem , vol.31 , pp. 433-440
    • Gautschi, K.1    Keller, B.2    Keller, H.3
  • 11
    • 0028062957 scopus 로고
    • Variance function as basis for the assessment of test performance: Methodological studies with two assays of prostate-specific antigen
    • Hänseler E, Keller B, Keller H. Variance function as basis for the assessment of test performance: Methodological studies with two assays of prostate-specific antigen. Clin Chem 1994;44: 2046-2052.
    • (1994) Clin Chem , vol.44 , pp. 2046-2052
    • Hänseler, E.1    Keller, B.2    Keller, H.3
  • 12
    • 84942220713 scopus 로고
    • Sensitivity and specificity of cocaine metabolite screening in view of the analytical performance of a fluorescence polarisation immunoassay
    • Hänseler E, Keller H. Sensitivity and specificity of cocaine metabolite screening in view of the analytical performance of a fluorescence polarisation immunoassay. Eur J Clin Chem Clin Biochem 1994;32:865-871.
    • (1994) Eur J Clin Chem Clin Biochem , vol.32 , pp. 865-871
    • Hänseler, E.1    Keller, H.2
  • 13
    • 0028340134 scopus 로고
    • Charakterisierung von Nachweisgrenzen. Messgrenzen und analytischer Sensitivität mittels eines standartisierten Verfahrens
    • Hänseler E, Keller H. Charakterisierung von Nachweisgrenzen. Messgrenzen und analytischer Sensitivität mittels eines standartisierten Verfahrens. Lab Med 1994;18:260-264.
    • (1994) Lab Med , vol.18 , pp. 260-264
    • Hänseler, E.1    Keller, H.2
  • 14
    • 0000806959 scopus 로고
    • A reliable method of estimating the vari-ance function in immunoassay
    • Sadler WA, Smith MH. A reliable method of estimating the vari-ance function in immunoassay. Computional Statistics and Data Analysis 1986;3:227-239.
    • (1986) Computional Statistics and Data Analysis , vol.3 , pp. 227-239
    • Sadler, W.A.1    Smith, M.H.2
  • 16
    • 0003024424 scopus 로고
    • The precision profile: 1st use in assay design, assessment and quality control
    • Hunter WM, Corrie JET, eds. Edinburgh: Churchill Livingstone
    • Ekins RP. The precision profile: 1st use in assay design, assessment and quality control. In: Hunter WM, Corrie JET, eds. Immunoassay for Clinical Chemistry. ed 2. Edinburgh: Churchill Livingstone, 1983.
    • (1983) Immunoassay for Clinical Chemistry. Ed 2
    • Ekins, R.P.1
  • 17
    • 0023318906 scopus 로고
    • Performance criteria for appropriate characterization of (highly) sensitive thyrotropin assays
    • Bayer MF. Performance criteria for appropriate characterization of (highly) sensitive thyrotropin assays. Clin Chem 1987;33: 630-631.
    • (1987) Clin Chem , vol.33 , pp. 630-631
    • Bayer, M.F.1
  • 18
    • 0014912813 scopus 로고
    • Biological and analytical components of variation in long-term studies of serum constituents in normal subjects
    • Cotlove E, Harris EK, Williams GZ. Biological and analytical components of variation in long-term studies of serum constituents in normal subjects. Clin Chcm 1970;16:1028-1032.
    • (1970) Clin Chcm , vol.16 , pp. 1028-1032
    • Cotlove, E.1    Harris, E.K.2    Williams, G.Z.3
  • 19
    • 0008957463 scopus 로고
    • Evaluation of precision
    • Werner M, ed. Boca Raton, FL: CRC Press
    • Ross WJ. Evaluation of precision. In: Werner M, ed. Handbook of Clinical Chemistry. Boca Raton, FL: CRC Press, 1982.
    • (1982) Handbook of Clinical Chemistry
    • Ross, W.J.1
  • 21
    • 0023601895 scopus 로고
    • Special report. Desirable standards for hematology tests: A proposal
    • Fraser CG. Special report. Desirable standards for hematology tests: A proposal. Am J Clin Pathol 1987;88:667-669.
    • (1987) Am J Clin Pathol , vol.88 , pp. 667-669
    • Fraser, C.G.1
  • 22
    • 0025086837 scopus 로고
    • Setting analytical goals for random analytical error in specific clinical monitoring situations
    • Fraser CG. Peterson PH, Larsen ML. Setting analytical goals for random analytical error in specific clinical monitoring situations. Clin Chem 1990;36:1625-1628.
    • (1990) Clin Chem , vol.36 , pp. 1625-1628
    • Fraser, C.G.1    Peterson, P.H.2    Larsen, M.L.3
  • 24
    • 8944237411 scopus 로고
    • Analyte des kleinen Blutbildes
    • Boll I, Heller S, eds. Heidelberg: Springer Verlag
    • Stobbe H. Analyte des kleinen Blutbildes. In: Boll I, Heller S, eds. Praktische Blutzelldiagnostik. INSTAND Schriftenreihe Bd. 7. Heidelberg: Springer Verlag, 1991, pp 44-90.
    • (1991) Praktische Blutzelldiagnostik. INSTAND Schriftenreihe , vol.7 , pp. 44-90
    • Stobbe, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.