메뉴 건너뛰기




Volumn 10, Issue 4, 1996, Pages 474-476

Methylene blue does not neutralize heparin after cardiopulmonary bypass

Author keywords

cardiopulmonary bypass; heparin; methylene blue; protamine

Indexed keywords

HEPARIN; METHYLENE BLUE; PROTAMINE;

EID: 0029949778     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(05)80007-2     Document Type: Article
Times cited : (5)

References (12)
  • 2
    • 76549251203 scopus 로고
    • Effect of thiazine, oxazine, and phenazine dyes on normal and heparinized rabbit plasma
    • Haley T Stolarsky F Effect of thiazine, oxazine, and phenazine dyes on normal and heparinized rabbit plasma Proc Soc Exp Biol Med 73 1950 103 107
    • (1950) , pp. 103-107
    • Haley, T1    Stolarsky, F2
  • 3
    • 0142112665 scopus 로고
    • The control of methemoglobinemia with methylene blue
    • Wendel WB The control of methemoglobinemia with methylene blue J Clin Invest 18 1938 179 185
    • (1938) J Clin Invest , vol.18 , pp. 179-185
    • Wendel, WB1
  • 5
    • 0024323438 scopus 로고
    • Methylene blue for neutralization of heparin
    • Sloand EM Kessler CM McIntosh CL Methylene blue for neutralization of heparin Thromb Res 54 1989 677 686
    • (1989) Thromb Res , vol.54 , pp. 677-686
    • Sloand, EM1    Kessler, CM2    McIntosh, CL3
  • 6
    • 85113078232 scopus 로고
    • What is the concentration of hexadimethrine and methylene blue required for neutralization of heparin following cardiopulmonary bypass?
    • Kikura M Lee MK Levy JH What is the concentration of hexadimethrine and methylene blue required for neutralization of heparin following cardiopulmonary bypass? Anesthesiology 81 1994 A177
    • (1994) Anesthesiology , vol.81 , pp. A177
    • Kikura, M1    Lee, MK2    Levy, JH3
  • 7
    • 0023031885 scopus 로고
    • Effects of intravenously administered dyes on pulse oximetry readings
    • Scheller MS Unger RJ Kelner J Effects of intravenously administered dyes on pulse oximetry readings Anesthesiology 65 1986 550 552
    • (1986) Anesthesiology , vol.65 , pp. 550-552
    • Scheller, MS1    Unger, RJ2    Kelner, J3
  • 8
    • 0024325235 scopus 로고
    • Desaturation noted by pulmonary artery catheter oximeter after methylene blue injection
    • Varon AJ Anderson HB Civetta JM Desaturation noted by pulmonary artery catheter oximeter after methylene blue injection Anesthesiology 71 1989 791 794
    • (1989) Anesthesiology , vol.71 , pp. 791-794
    • Varon, AJ1    Anderson, HB2    Civetta, JM3
  • 9
    • 0027567463 scopus 로고
    • Intraoperative identification of parathyroid glands with methylene blue infusion
    • Derom AF Wallaert PC Janzing HM Intraoperative identification of parathyroid glands with methylene blue infusion Am J Surg 165 1993 380 382
    • (1993) Am J Surg , vol.165 , pp. 380-382
    • Derom, AF1    Wallaert, PC2    Janzing, HM3
  • 10
    • 0017139397 scopus 로고
    • Hypertension and decreased renal blood flow following methylene blue injection
    • Birch AA Boyce WH Hypertension and decreased renal blood flow following methylene blue injection Anesth Analg 55 1976 674 676
    • (1976) Anesth Analg , vol.55 , pp. 674-676
    • Birch, AA1    Boyce, WH2
  • 11
    • 0026042737 scopus 로고
    • In vivo attenuation of endothelium-dependent pulmonary vasodilation by methylene blue
    • Fineman JR Crowley MR Heymann MA In vivo attenuation of endothelium-dependent pulmonary vasodilation by methylene blue J Appl Physiol 71 1991 735 741
    • (1991) J Appl Physiol , vol.71 , pp. 735-741
    • Fineman, JR1    Crowley, MR2    Heymann, MA3
  • 12
    • 0026767591 scopus 로고
    • Methylene blue increases systemic vascular resistance in human septic shock
    • Schneider Lutun P Hasselmann M Methylene blue increases systemic vascular resistance in human septic shock Crit Care Med 18 1992 309 311
    • (1992) Crit Care Med , vol.18 , pp. 309-311
    • Schneider1    Lutun, P2    Hasselmann, M3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.