메뉴 건너뛰기




Volumn 11, Issue 8, 1996, Pages 783-789

Co-immobilized L-lactate oxidase and L-lactate dehydrogenase on a film mounted on oxygen electrode for highly sensitive L-lactate determination

Author keywords

E. coli L lactate determination; L lactate biosensor; L lactate dehydrogenase co immobilization; L lactate oxidase; L lactate recycling

Indexed keywords

BIOASSAY; CELL CULTURE; COLIFORM BACTERIA; ELECTROCHEMICAL ELECTRODES; ENZYME IMMOBILIZATION; METABOLISM; ORGANIC ACIDS; SUBSTRATES;

EID: 0029948422     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(96)85929-X     Document Type: Conference Paper
Times cited : (18)

References (16)
  • 1
    • 0026445904 scopus 로고
    • Reducing the influence of sample oxygen in biosensor design
    • Albantov, A. F. (1992). Reducing the influence of sample oxygen in biosensor design. Biosensors & Bioelectronics, 7, 575-585.
    • (1992) Biosensors & Bioelectronics , vol.7 , pp. 575-585
    • Albantov, A.F.1
  • 2
    • 0027428794 scopus 로고
    • Kinetics of lactate fermentation and citrate bioconversion by Lactococcus lactis sp lactis in batch culture
    • Cachon, R. & Divies, C. (1993). Kinetics of lactate fermentation and citrate bioconversion by Lactococcus lactis sp lactis in batch culture. J. Appl. Bacteriol., 4, 387-392.
    • (1993) J. Appl. Bacteriol. , vol.4 , pp. 387-392
    • Cachon, R.1    Divies, C.2
  • 5
    • 0007562895 scopus 로고
    • A multipurpose enzyme sensor based on alcohol oxidase
    • Hopkins, T. R. (1985). A multipurpose enzyme sensor based on alcohol oxidase. Int. Biotechnol. Lab., 3, 20-25.
    • (1985) Int. Biotechnol. Lab. , vol.3 , pp. 20-25
    • Hopkins, T.R.1
  • 6
    • 0039894150 scopus 로고
    • Improved enzyme sensor for glucose with an ultrafiltration membrane
    • Koyama, M., Sato, Y., Aizawa, M. & Suzuki, S. (1980). Improved enzyme sensor for glucose with an ultrafiltration membrane. Anal. Chim. Acta, 116, 307-314.
    • (1980) Anal. Chim. Acta , vol.116 , pp. 307-314
    • Koyama, M.1    Sato, Y.2    Aizawa, M.3    Suzuki, S.4
  • 8
    • 4244186437 scopus 로고
    • An enzyme electrode for L-lactate with a chemically amplified response
    • Mizutani, F., Yamanaka, T., Tanabe, Y. & Tsuda, K. (1985). An enzyme electrode for L-lactate with a chemically amplified response. Analyt. Chem. Ata, 47, 153-166.
    • (1985) Analyt. Chem. Ata , vol.47 , pp. 153-166
    • Mizutani, F.1    Yamanaka, T.2    Tanabe, Y.3    Tsuda, K.4
  • 9
    • 0028489808 scopus 로고
    • "Wired" enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances
    • Ohara, T. J., Rajagopalan, R. & Heller, A. (1994). "Wired" enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances. Anal. Chem., 66, 2451-2457.
    • (1994) Anal. Chem. , vol.66 , pp. 2451-2457
    • Ohara, T.J.1    Rajagopalan, R.2    Heller, A.3
  • 10
    • 0028064290 scopus 로고
    • On-line enzymatic amplification by substrate cycling in a dual bireactor with rotation and amperometric detection
    • Raba, J. & Motola, H. A. (1994). On-line enzymatic amplification by substrate cycling in a dual bireactor with rotation and amperometric detection. Analyt. Biochem., 2, 297-302.
    • (1994) Analyt. Biochem. , vol.2 , pp. 297-302
    • Raba, J.1    Motola, H.A.2
  • 11
    • 0001641339 scopus 로고
    • High sensitivity enzyme thermistor determination of L-lactate by substrate recycling
    • Scheller, F., Siegbahn, N., Danielsson, B., Mosbach, K. (1985). High sensitivity enzyme thermistor determination of L-lactate by substrate recycling. Anal. Chem. 57, 1740-1743.
    • (1985) Anal. Chem. , vol.57 , pp. 1740-1743
    • Scheller, F.1    Siegbahn, N.2    Danielsson, B.3    Mosbach, K.4
  • 12
    • 2042471093 scopus 로고
    • Specific features of biosensors
    • W. Gopel, T.A. Jones, M. Kleitz, I. Lunström & T. Seyama (eds.). VCH, Weinheim
    • Schmidt, H. L., Schuman, W., Scheller, N. & Schubert, F. (1991). Specific features of biosensors. In: Chemical and Biochemical Sensors, W. Gopel, T.A. Jones, M. Kleitz, I. Lunström & T. Seyama (eds.). VCH, Weinheim, Vol. 3, pp. 773-784.
    • (1991) Chemical and Biochemical Sensors , vol.3 , pp. 773-784
    • Schmidt, H.L.1    Schuman, W.2    Scheller, N.3    Schubert, F.4
  • 13
  • 14
    • 0027608433 scopus 로고
    • Detection of bacterial contamination in sterile UHT milk using L-lactate biosensor
    • Skladal, P., Mascini, M., Salvadori, C. & Zannoni, G. (1993). Detection of bacterial contamination in sterile UHT milk using L-lactate biosensor. Enzyme Microbiol. Technol., 6, 508-512.
    • (1993) Enzyme Microbiol. Technol. , vol.6 , pp. 508-512
    • Skladal, P.1    Mascini, M.2    Salvadori, C.3    Zannoni, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.