메뉴 건너뛰기




Volumn 42, Issue 5, 1996, Pages 711-717

Impact of point-of-care testing on patients' length of stay in a large emergency department

Author keywords

electrolytes; hematocrit; laboratory management

Indexed keywords

ARTICLE; CHLORIDE BLOOD LEVEL; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; DIAGNOSTIC ACCURACY; EMERGENCY WARD; GLUCOSE BLOOD LEVEL; HOSPITAL ADMISSION; HOSPITAL DISCHARGE; HUMAN; LABORATORY TEST; LENGTH OF STAY; MAJOR CLINICAL STUDY; POTASSIUM BLOOD LEVEL; SODIUM BLOOD LEVEL; UREA NITROGEN BLOOD LEVEL;

EID: 0029947392     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.5.711     Document Type: Article
Times cited : (135)

References (15)
  • 2
    • 0027410804 scopus 로고
    • Evaluation of a novel point of care system, the i-STAT portable clinical analyzer
    • Erickson KA, Wilding P. Evaluation of a novel point of care system, the i-STAT portable clinical analyzer. Clin Chem 1993;39:283-7.
    • (1993) Clin Chem , vol.39 , pp. 283-287
    • Erickson, K.A.1    Wilding, P.2
  • 3
    • 0027136771 scopus 로고
    • The evaluation of a portable chemical analyzer in the emergency department
    • Woo J, McCabe JB, Chauncey D, Schug T, Henry JB. The evaluation of a portable chemical analyzer in the emergency department. Am J Clin Pathol 1993;100:599-605.
    • (1993) Am J Clin Pathol , vol.100 , pp. 599-605
    • Woo, J.1    McCabe, J.B.2    Chauncey, D.3    Schug, T.4    Henry, J.B.5
  • 4
    • 0029259012 scopus 로고
    • Evaluation of a portable clinical blood analyzer in the emergency department
    • Sands VM, Auerbach PS, Birnbaum J, Green M. Evaluation of a portable clinical blood analyzer in the emergency department. Acad Emerg Med 1995;2:172-8.
    • (1995) Acad Emerg Med , vol.2 , pp. 172-178
    • Sands, V.M.1    Auerbach, P.S.2    Birnbaum, J.3    Green, M.4
  • 6
    • 0029156308 scopus 로고
    • Novel nonseparation sandwich-type electrochemical enzyme immunoassay system for detecting marker proteins in undiluted blood
    • Meyerhoff ME, Duan C, Mensel M. Novel nonseparation sandwich-type electrochemical enzyme immunoassay system for detecting marker proteins in undiluted blood. Clin Chem 1995;41:1378-84.
    • (1995) Clin Chem , vol.41 , pp. 1378-1384
    • Meyerhoff, M.E.1    Duan, C.2    Mensel, M.3
  • 7
    • 0028797499 scopus 로고
    • Cost analysis of point of care laboratory testing in a community hospital
    • Nosanchuk JS, Keefner R. Cost analysis of point of care laboratory testing in a community hospital. Am J Clin Pathol 1995;103: 240-3.
    • (1995) Am J Clin Pathol , vol.103 , pp. 240-243
    • Nosanchuk, J.S.1    Keefner, R.2
  • 8
    • 0028120370 scopus 로고
    • The fiscal consequence of central vs distributed testing of glucose
    • Winkelman JW, Wybenga DR, Tanasijevic MJ. The fiscal consequence of central vs distributed testing of glucose. Clin Chem 1994;40:1628-30.
    • (1994) Clin Chem , vol.40 , pp. 1628-1630
    • Winkelman, J.W.1    Wybenga, D.R.2    Tanasijevic, M.J.3
  • 9
    • 0027138811 scopus 로고
    • Point-of-care testing in the emergency department
    • Jatlow P. Point-of-care testing in the emergency department. Am J Clin Pathol 1993;100:591.
    • (1993) Am J Clin Pathol , vol.100 , pp. 591
    • Jatlow, P.1
  • 10
    • 0027331594 scopus 로고
    • Does the emergency department need a dedicated stat lab?
    • Saxena S, Wong ET. Does the emergency department need a dedicated stat lab? Am J Clin Pathol 1993;100:606-10.
    • (1993) Am J Clin Pathol , vol.100 , pp. 606-610
    • Saxena, S.1    Wong, E.T.2
  • 11
    • 0028561959 scopus 로고
    • Point-of-care versus central laboratory testing: An economic analysis in an academic medical center
    • Tsai WW, Nash DB, Seamonds B, Weis GJ. Point-of-care versus central laboratory testing: an economic analysis in an academic medical center. Clin Ther 1994;16:898-910.
    • (1994) Clin Ther , vol.16 , pp. 898-910
    • Tsai, W.W.1    Nash, D.B.2    Seamonds, B.3    Weis, G.J.4
  • 12
    • 0346663994 scopus 로고
    • Numerical evaluation of formed elements of blood
    • Sonnenwirth A, Jarett LD, eds. St. Louis, MO: CV Mosby
    • Bauer JD. Numerical evaluation of formed elements of blood. In: Sonnenwirth A, Jarett LD, eds. Gradwohl's clinical laboratory methods and diagnosis. St. Louis, MO: CV Mosby, 1980:785-808.
    • (1980) Gradwohl's Clinical Laboratory Methods and Diagnosis , pp. 785-808
    • Bauer, J.D.1
  • 13
    • 0001884644 scopus 로고
    • Individual comparisons by ranking methods
    • Wilcoxon F. Individual comparisons by ranking methods. Biometrics Bull 1945;1:80-3.
    • (1945) Biometrics Bull , vol.1 , pp. 80-83
    • Wilcoxon, F.1
  • 14
    • 0001370087 scopus 로고
    • Nonparametric confidence intervals for a shift parameter
    • Lehmann EL. Nonparametric confidence intervals for a shift parameter. Ann Math Statist 1963;34:1507-12.
    • (1963) Ann Math Statist , vol.34 , pp. 1507-1512
    • Lehmann, E.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.