메뉴 건너뛰기




Volumn 37, Issue 1, 1996, Pages 34-40

Biomechanical testing of titanium self-tapping versus pretapped lag screw fixation of spiral metacarpal fractures

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM;

EID: 0029945239     PISSN: 01487043     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000637-199607000-00006     Document Type: Article
Times cited : (3)

References (21)
  • 1
    • 0027209873 scopus 로고
    • Spiral fracture fixation techniques
    • Br
    • Matloub HS, Jensen PL, Sanger JR, et al. Spiral fracture fixation techniques. J Hand Surg [Br] 1993;18B:515-519
    • (1993) J Hand Surg , vol.18 B , pp. 515-519
    • Matloub, H.S.1    Jensen, P.L.2    Sanger, J.R.3
  • 2
    • 0008875816 scopus 로고
    • Technique recommended by the ASIF Group. 3rd ed. Berlin: Springer-Verlag
    • Heim U, Pfeiffer KM. Small fragment manual, Technique recommended by the ASIF Group. 3rd ed. Berlin: Springer-Verlag, 1987:31-33
    • (1987) Small Fragment Manual , pp. 31-33
    • Heim, U.1    Pfeiffer, K.M.2
  • 3
    • 0000771564 scopus 로고
    • The use of small bone screws in the treatment of metacarpal, metatarsal and phalangeal fractures
    • Am
    • Kilbourne BC, Paul EG. The use of small bone screws in the treatment of metacarpal, metatarsal and phalangeal fractures. J Bone Joint Surg [Am] 1958;40A:375-383
    • (1958) J Bone Joint Surg , vol.40 A , pp. 375-383
    • Kilbourne, B.C.1    Paul, E.G.2
  • 4
    • 0023614420 scopus 로고
    • Fractures of the phalanges: Results of internal fixation using 1.5 mm and 2.0 mm A.O. screws
    • Br
    • Ford DJ, El-Hadidi S, Lunn PG, Burke FD. Fractures of the phalanges: results of internal fixation using 1.5 mm and 2.0 mm A.O. screws. J Hand Surg [Br] 1987;12B:28-33
    • (1987) J Hand Surg , vol.12 B , pp. 28-33
    • Ford, D.J.1    El-Hadidi, S.2    Lunn, P.G.3    Burke, F.D.4
  • 5
    • 0017135870 scopus 로고
    • Screw fixation for certain fractures of the phalanges and metacarpals
    • Am
    • Crawford GP. Screw fixation for certain fractures of the phalanges and metacarpals. J Bone Joint Surg [Am] 1976; 58A:487-492
    • (1976) J Bone Joint Surg , vol.58 A , pp. 487-492
    • Crawford, G.P.1
  • 7
    • 0017145755 scopus 로고
    • Force measurements in screw fixation
    • Nunamaker DM. Force measurements in screw fixation, J Biomech 1976;9:669-675
    • (1976) J Biomech , vol.9 , pp. 669-675
    • Nunamaker, D.M.1
  • 9
    • 0025357365 scopus 로고
    • The effect of repetitive screw hole use on the retentive strength of pre-tapped and self-tapped screws
    • Foley WL, Frost DE, Tucker MR. The effect of repetitive screw hole use on the retentive strength of pre-tapped and self-tapped screws. J Oral Maxillofac Surg 1990;48:264-267
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 264-267
    • Foley, W.L.1    Frost, D.E.2    Tucker, M.R.3
  • 10
    • 0024565314 scopus 로고
    • Comparison of compression and torque measurements of self-tapping and pre-tapped screws
    • Phillips JH, Rahn BA. Comparison of compression and torque measurements of self-tapping and pre-tapped screws. Plast Reconstr Surg 1989;83:447-456
    • (1989) Plast Reconstr Surg , vol.83 , pp. 447-456
    • Phillips, J.H.1    Rahn, B.A.2
  • 11
    • 0015694102 scopus 로고
    • Mechanical factors influencing the holding power of screws in compact bone
    • Br
    • Uhtoff HK. Mechanical factors influencing the holding power of screws in compact bone. J Bone Joint Surg [Br] 1973;55B:633-639
    • (1973) J Bone Joint Surg , vol.55 B , pp. 633-639
    • Uhtoff, H.K.1
  • 12
    • 0019490733 scopus 로고
    • In vivo evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws
    • Vangsness CT, Carter DR, Frankel VH. In vivo evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws. Clin Orthop 1981;157: 279-286
    • (1981) Clin Orthop , vol.157 , pp. 279-286
    • Vangsness, C.T.1    Carter, D.R.2    Frankel, V.H.3
  • 13
    • 0000781654 scopus 로고
    • A study of some factors which affect the strength of screws and their insertion and holding power in bone
    • Ansell RH, Scales JT. A study of some factors which affect the strength of screws and their insertion and holding power in bone. J Biomech 1968;1:279-302
    • (1968) J Biomech , vol.1 , pp. 279-302
    • Ansell, R.H.1    Scales, J.T.2
  • 14
    • 0016723088 scopus 로고
    • The holding power of orthopedic screws - In vivo
    • Schatzker J, Sanderson R, Murnaghan JP. The holding power of orthopedic screws - in vivo. Clin Orthop 1975; 108:115-126
    • (1975) Clin Orthop , vol.108 , pp. 115-126
    • Schatzker, J.1    Sanderson, R.2    Murnaghan, J.P.3
  • 15
    • 0028284544 scopus 로고
    • Effect of cyclical loading on the holding power of surgical screws
    • Firoozbakhsh KK, DeCoster TA, Moneim MS. Effect of cyclical loading on the holding power of surgical screws. Orthopedics 1994;17:607-611
    • (1994) Orthopedics , vol.17 , pp. 607-611
    • Firoozbakhsh, K.K.1    DeCoster, T.A.2    Moneim, M.S.3
  • 16
    • 0000389359 scopus 로고
    • Biomechanical characteristics of bone
    • Swanson SA. Biomechanical characteristics of bone. Adv Biomed Eng 1971;1:137-187
    • (1971) Adv Biomed Eng , vol.1 , pp. 137-187
    • Swanson, S.A.1
  • 17
    • 0027175806 scopus 로고
    • Basic biomechanical measurements of bone: A tutorial
    • Turner CH, Burr DB. Basic biomechanical measurements of bone: a tutorial. Bone 1993;14:595-608
    • (1993) Bone , vol.14 , pp. 595-608
    • Turner, C.H.1    Burr, D.B.2
  • 20


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.