메뉴 건너뛰기




Volumn 22, Issue 4, 1996, Pages 421-430

Hemodynamic assessment of carbomedics bileaflet heart valves by ultrasound: Studies in the aortic and mitral positions

Author keywords

Bernoulli equation; Doppler echocardiography; Heart valve; Hemodynamics

Indexed keywords

CARDIOVASCULAR SYSTEM; CATHETERS; DIFFERENTIAL EQUATIONS; ESTIMATION; HEMODYNAMICS; IMPLANTS (SURGICAL); PRESSURE DROP; PRESSURE EFFECTS; ULTRASONICS; VELOCITY;

EID: 0029937328     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/0301-5629(96)00030-0     Document Type: Article
Times cited : (4)

References (14)
  • 1
    • 0027499532 scopus 로고
    • Echocardiographic description of the Carbomedics bileaflet prosthetic heart valve
    • Chambers J, Cross J, Deverall P, Sowton E. Echocardiographic description of the Carbomedics bileaflet prosthetic heart valve. J Am Coll Cardiol 1993; 21:398-405.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 398-405
    • Chambers, J.1    Cross, J.2    Deverall, P.3    Sowton, E.4
  • 2
    • 0021592542 scopus 로고
    • Pulsatile flow past aortic valve bioprostheses in a model human aorta
    • Chandran KB, Cabell GN, Khalighi B, Chen CJ. Pulsatile flow past aortic valve bioprostheses in a model human aorta. J Biomech 1984; 17:609-619.
    • (1984) J Biomech , vol.17 , pp. 609-619
    • Chandran, K.B.1    Cabell, G.N.2    Khalighi, B.3    Chen, C.J.4
  • 3
    • 0026571976 scopus 로고
    • Doppler sonographic evaluation of the Carbomedics bileaflet valve prosthesis: One-year experience
    • Globits S, Rodler S, Mayr H, Moritz A, Mlczoch J. Doppler sonographic evaluation of the Carbomedics bileaflet valve prosthesis: One-year experience. J Cardiac Surg 1992; 7:9-16.
    • (1992) J Cardiac Surg , vol.7 , pp. 9-16
    • Globits, S.1    Rodler, S.2    Mayr, H.3    Moritz, A.4    Mlczoch, J.5
  • 5
    • 0026527253 scopus 로고
    • Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: Comparison of noninvasive and invasive techniques
    • Ihlen H, Molstad P, Simonsen S, Vatne K, Ovrum E. Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: Comparison of noninvasive and invasive techniques. Am Heart J 1992; 123:151-159.
    • (1992) Am Heart J , vol.123 , pp. 151-159
    • Ihlen, H.1    Molstad, P.2    Simonsen, S.3    Vatne, K.4    Ovrum, E.5
  • 7
    • 0024583764 scopus 로고
    • Parameters and methods for testing artificial heart valves
    • Kohler JC, Tech JG. Parameters and methods for testing artificial heart valves. Int J Artif Org 1989; 4:252-260.
    • (1989) Int J Artif Org , vol.4 , pp. 252-260
    • Kohler, J.C.1    Tech, J.G.2
  • 8
    • 0023330235 scopus 로고
    • Laboratory testing of prosthetic heart valves
    • Reul H, Giersiepen M, Knott E. Laboratory testing of prosthetic heart valves. Eng Med 1987; 16:67-76.
    • (1987) Eng Med , vol.16 , pp. 67-76
    • Reul, H.1    Giersiepen, M.2    Knott, E.3
  • 9
    • 0038094775 scopus 로고
    • An in vitro comparison of 29 mm mitral CarboMedics and Saint Jude Medical artificial heart valves
    • Bodnar E, ed. London: IRC Publishers
    • Richard GJ, O'Bannon W, More RB. An in vitro comparison of 29 mm mitral CarboMedics and Saint Jude Medical artificial heart valves. In: Bodnar E, ed. Surgery for heart valve disease. London: IRC Publishers, 1990:628-633.
    • (1990) Surgery for Heart Valve Disease , pp. 628-633
    • Richard, G.J.1    O'Bannon, W.2    More, R.B.3
  • 10
    • 2642589801 scopus 로고
    • Experience with the SJM prosthesis: Studies on cinefluorography, hemolysis, and tricuspid replacement
    • DeBakey ME, ed. New York: Yoke Medical Books
    • Sezai Y. Experience with the SJM prosthesis: Studies on cinefluorography, hemolysis, and tricuspid replacement. In: DeBakey ME, ed. Advances in cardiac valves. New York: Yoke Medical Books, 1983:87-102.
    • (1983) Advances in Cardiac Valves , pp. 87-102
    • Sezai, Y.1
  • 11
    • 0022632209 scopus 로고
    • An instrument for the measurement of in vitro velocity and turbulence shear stress in the immediate vicinity of prosthetic heart valves
    • Woo Y-R, Yoganathan AP. An instrument for the measurement of in vitro velocity and turbulence shear stress in the immediate vicinity of prosthetic heart valves. Life Support Syst 1986a; 4:47-62.
    • (1986) Life Support Syst , vol.4 , pp. 47-62
    • Woo, Y.-R.1    Yoganathan, A.P.2
  • 12
    • 0022592273 scopus 로고
    • In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses
    • Woo Y-R, Yoganathan AP. In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses. J Biomech 1986b; 19:39-51.
    • (1986) J Biomech , vol.19 , pp. 39-51
    • Woo, Y.-R.1    Yoganathan, A.P.2
  • 13
    • 0018394485 scopus 로고
    • In vitro velocity measurements in the near vicinity of aortic valve prostheses
    • Yoganathan AP, Corcoran WH, Harrison EC. In vitro velocity measurements in the near vicinity of aortic valve prostheses. J Biomech 1979; 12:135-152.
    • (1979) J Biomech , vol.12 , pp. 135-152
    • Yoganathan, A.P.1    Corcoran, W.H.2    Harrison, E.C.3
  • 14
    • 0022646878 scopus 로고
    • Turbulence shear stress measurements in the vicinity of aortic heart valve prostheses
    • Yoganathan AP, Woo Y-R, Sung H-W. Turbulence shear stress measurements in the vicinity of aortic heart valve prostheses. J Biomech 1986; 19:433-442.
    • (1986) J Biomech , vol.19 , pp. 433-442
    • Yoganathan, A.P.1    Woo, Y.-R.2    Sung, H.-W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.