메뉴 건너뛰기




Volumn 11, Issue 8, 1996, Pages 725-734

Use of the USDT flow immunosensor for quantitation of benzoylecgonine in urine

Author keywords

Benzolegonine; Biosensor; Cocaine; Flow; Immunosensory; Urine

Indexed keywords

ANTIBODIES; BIOASSAY; BIOSENSORS; FLOW MEASUREMENT; FLOW MEASURING INSTRUMENTS; GAS CHROMATOGRAPHY; MASS SPECTROMETRY; ORGANIC COMPOUNDS;

EID: 0029933924     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(96)85923-9     Document Type: Conference Paper
Times cited : (21)

References (19)
  • 1
    • 0002739555 scopus 로고
    • Enzyme-linked immunosorbent assay (ELISA): Theoretical and practical aspects
    • E. T. Maggio (ed.). CA:CRC
    • Brian, R. & Engvall, E. (1980). Enzyme-linked immunosorbent assay (ELISA): theoretical and practical aspects. In: Enzyme Immunoassay, E. T. Maggio (ed.). CA:CRC, pp. 167-179.
    • (1980) Enzyme Immunoassay , pp. 167-179
    • Brian, R.1    Engvall, E.2
  • 3
    • 0023619278 scopus 로고
    • Lake of validity of the KDI quick test drug screen for detection of bezoylecgonine in urine
    • Cone, E. J. & Menchen, S. L. (1987). Lake of validity of the KDI quick test drug screen for detection of bezoylecgonine in urine. J. Anal. Toxicol., 11, 267-277.
    • (1987) J. Anal. Toxicol. , vol.11 , pp. 267-277
    • Cone, E.J.1    Menchen, S.L.2
  • 4
    • 0023925233 scopus 로고
    • Validity testing of the TDx™ cocaine metabolite assay with human specimens obtained after intravenous cocaine administration
    • Cone, E. J., Menchen, S. L. & Mitchell, J. (1988). Validity testing of the TDx™ cocaine metabolite assay with human specimens obtained after intravenous cocaine administration. Forensic. Sci. Int., 37, 265-275.
    • (1988) Forensic. Sci. Int. , vol.37 , pp. 265-275
    • Cone, E.J.1    Menchen, S.L.2    Mitchell, J.3
  • 5
    • 0017338706 scopus 로고
    • Urinary excretion of immunologically reactive metabolites after internasal administration of cocaine, as followed by enzyme immunoassay
    • Craig, V. D., Robert, B., Brash, G. & Jatlow, P. (1977). Urinary excretion of immunologically reactive metabolites after internasal administration of cocaine, as followed by enzyme immunoassay. Clin. Chem., 23, 241-244.
    • (1977) Clin. Chem. , vol.23 , pp. 241-244
    • Craig, V.D.1    Robert, B.2    Brash, G.3    Jatlow, P.4
  • 7
    • 0027617019 scopus 로고
    • Theory of a sequential addition competitive binding immunoassay based on high-performance immunoaffinity chromatography
    • Hage, D. S., Thomas, D. H. & Beck, M. S. (1993). Theory of a sequential addition competitive binding immunoassay based on high-performance immunoaffinity chromatography. Anal. Chem., 65, 1622-1630.
    • (1993) Anal. Chem. , vol.65 , pp. 1622-1630
    • Hage, D.S.1    Thomas, D.H.2    Beck, M.S.3
  • 8
    • 0001016250 scopus 로고
    • Immunoassays for the detection of 2,4-D and picloram in river water and urine
    • Hall, J. C., Deschamps, R. J. A. & Krieg, K. K. (1989). Immunoassays for the detection of 2,4-D and picloram in river water and urine. J. Agric. Food Chem., 37, 981-984.
    • (1989) J. Agric. Food Chem. , vol.37 , pp. 981-984
    • Hall, J.C.1    Deschamps, R.J.A.2    Krieg, K.K.3
  • 11
    • 0343122683 scopus 로고
    • Drug detection using the flow immunosensor
    • Biosensor Design and Application, P. R. Mathewson & J. W. Finley (eds.). American Chemical Society, Washington, DC
    • Ligler, F. S., Kusterbeck, A. W., Ogert, R. A. & Wemhoff, G. A. (1992). Drug detection using the flow immunosensor. In: Biosensor Design and Application, P. R. Mathewson & J. W. Finley (eds.). American Chemical Society, Washington, DC, ACS Symposium Series, Vol. 511, pp. 73-80.
    • (1992) ACS Symposium Series , vol.511 , pp. 73-80
    • Ligler, F.S.1    Kusterbeck, A.W.2    Ogert, R.A.3    Wemhoff, G.A.4
  • 14
    • 0023697266 scopus 로고
    • Urine testing in the detection of drugs of abuse
    • Schwartz, R. H. (1988). Urine testing in the detection of drugs of abuse. Arch. Int. Med., 148, 2407-2412.
    • (1988) Arch. Int. Med. , vol.148 , pp. 2407-2412
    • Schwartz, R.H.1
  • 15
    • 0006317643 scopus 로고
    • The role of HPLC in therapeutic drug monitoring and drug-of-abuse screening
    • Shihabi, Z. K. & McCormick, C. P. (1990). The role of HPLC in therapeutic drug monitoring and drug-of-abuse screening. Biochromatography, 5, 121-126.
    • (1990) Biochromatography , vol.5 , pp. 121-126
    • Shihabi, Z.K.1    McCormick, C.P.2
  • 16
    • 0024506254 scopus 로고
    • An evaluation of six methods for the detection of drug of abuse in urine
    • Simpson, D., Jarvie, D. R. & Hyworth, R. (1989). An evaluation of six methods for the detection of drug of abuse in urine. Ann. Clin. Biochem., 26, 172-181.
    • (1989) Ann. Clin. Biochem. , vol.26 , pp. 172-181
    • Simpson, D.1    Jarvie, D.R.2    Hyworth, R.3
  • 17
    • 0023972281 scopus 로고
    • A discussion of the KDI quick test drug screen
    • Wells, H. & Cone, E. J. (1988). A discussion of the KDI quick test drug screen. J. Anal. Toxicol., 12, 111.
    • (1988) J. Anal. Toxicol. , vol.12 , pp. 111
    • Wells, H.1    Cone, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.