메뉴 건너뛰기




Volumn 49, Issue 5, 1996, Pages 1396-1400

Correction of acidosis in CAPD decreases whole body protein degradation

Author keywords

[No Author keywords available]

Indexed keywords

ACIDOSIS; ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; CONTROLLED CLINICAL TRIAL; FEMALE; HUMAN; MALE; PRIORITY JOURNAL; PROTEIN DEGRADATION; RANDOMIZED CONTROLLED TRIAL;

EID: 0029931350     PISSN: 00852538     EISSN: None     Source Type: Journal    
DOI: 10.1038/ki.1996.196     Document Type: Article
Times cited : (137)

References (9)
  • 1
    • 0027249311 scopus 로고
    • Correction of acidosis in humans with chronic renal failure decreases protein degradation and amino acid oxidation
    • REAICH D, CHANNON, SCRIMGEOUR CM, DALEY SE, WILKINSON R, GOODSIHP THJ: Correction of acidosis in humans with chronic renal failure decreases protein degradation and amino acid oxidation. Am J Physiol 265:E230-E235, 1993
    • (1993) Am J Physiol , vol.265
    • Reaich, D.1    Channon2    Scrimgeour, C.M.3    Daley, S.E.4    Wilkinson, R.5    Goodsihp, T.H.J.6
  • 2
    • 0022551936 scopus 로고
    • Metabolic acidosis stimulates whole body protein degradation and leucine oxidation by a glucocorticoid-dependent mechanism
    • MAY RC, MASUD T, LOGUE B, BAILEY J, ENGLAND BK: Metabolic acidosis stimulates whole body protein degradation and leucine oxidation by a glucocorticoid-dependent mechanism. J Clin Invest 77:614-621, 1986
    • (1986) J Clin Invest , vol.77 , pp. 614-621
    • May, R.C.1    Masud, T.2    Logue, B.3    Bailey, J.4    England, B.K.5
  • 5
    • 0025832294 scopus 로고
    • A new stable bicarbonate dialysis solution for peritoneal dialysis: Preliminary report
    • YATZIDIS H: A new stable bicarbonate dialysis solution for peritoneal dialysis: preliminary report. Perit Dial Int 11:224-227, 1993
    • (1993) Perit Dial Int , vol.11 , pp. 224-227
    • Yatzidis, H.1
  • 7
    • 0015051223 scopus 로고
    • Measurement of total body potassium with a shadow shield whole body counter: Calibration and errors
    • BODDY K, KING PC, TOTHILL P, STRONG JA: Measurement of total body potassium with a shadow shield whole body counter: Calibration and errors. Phys Med Biol 16:275-282, 1971
    • (1971) Phys Med Biol , vol.16 , pp. 275-282
    • Boddy, K.1    King, P.C.2    Tothill, P.3    Strong, J.A.4
  • 8
    • 0019458610 scopus 로고
    • Use of a heated superficial hand vein as an alternative site for the measurement of amino acid concentrations and for the study of glucose and alanine kinetics in man
    • ABUMRAD NN, RABIN D, DIAMOND MP, LACY WW: Use of a heated superficial hand vein as an alternative site for the measurement of amino acid concentrations and for the study of glucose and alanine kinetics in man. Metab Clin Exp 30:936-940, 1981
    • (1981) Metab Clin Exp , vol.30 , pp. 936-940
    • Abumrad, N.N.1    Rabin, D.2    Diamond, M.P.3    Lacy, W.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.