메뉴 건너뛰기




Volumn 31, Issue 6, 1996, Pages 333-337

The accuracy of computed tomography-based linear measurements of human femora and titanium stem

Author keywords

Computed tomography; femur; Half maximum height; hip arthroplasty; image analysis; profile window; titanium stem

Indexed keywords

TITANIUM;

EID: 0029931151     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199606000-00004     Document Type: Article
Times cited : (14)

References (18)
  • 3
    • 0023227991 scopus 로고
    • Design of custom hip stem prostheses using three-dimensional CT modeling
    • Robertson DD, Walker PS, Granholm JW, et al. Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 1987;11:804-809.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 804-809
    • Robertson, D.D.1    Walker, P.S.2    Granholm, J.W.3
  • 6
    • 0019978056 scopus 로고
    • The effects of scatter in x-ray computed tomography
    • Joseph PM, Spital RD. The effects of scatter in x-ray computed tomography. Med Phys 1982;9:464-472.
    • (1982) Med Phys , vol.9 , pp. 464-472
    • Joseph, P.M.1    Spital, R.D.2
  • 7
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • Roberson DD, Weiss PJ, Fishman EK, Magid D, Walker PS. Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. J Comput Assist Tomogr 1988;12:236-241.
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 236-241
    • Roberson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 8
    • 0027162186 scopus 로고
    • Liear measurements of cortical bone and dental enamel by computed tomography: Applications and problems
    • Spoor CF, Zonneveld FW, Macho GA. Liear measurements of cortical bone and dental enamel by computed tomography: Applications and problems. Am J Phys Anthropol 1993;91:469-84.
    • (1993) Am J Phys Anthropol , vol.91 , pp. 469-484
    • Spoor, C.F.1    Zonneveld, F.W.2    Macho, G.A.3
  • 9
    • 0039784995 scopus 로고
    • A comparison of the accuracy of periapical, panoramic, and computed tomographic radiographs in locating the mandibular canal
    • Michael S, James A, Robert AF. A comparison of the accuracy of periapical, panoramic, and computed tomographic radiographs in locating the mandibular canal. Int J Oral Maxillofac Implants 1994;9:455-460.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 455-460
    • Michael, S.1    James, A.2    Robert, A.F.3
  • 10
    • 0021361323 scopus 로고
    • An investigation into the problems of attenuation and area measurements made from CT images of pulmonary nodules
    • Checkley D, Zhu X, Antoun N, Chen S, Isherwood I. An investigation into the problems of attenuation and area measurements made from CT images of pulmonary nodules. J Comput Assist Tomogr 1984;8:237-243.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 237-243
    • Checkley, D.1    Zhu, X.2    Antoun, N.3    Chen, S.4    Isherwood, I.5
  • 11
    • 0022573365 scopus 로고
    • Accuracy of area measurements made from MR images compared with computed tomography
    • Zhu X, Checkley D, Hickey D, Isherwood I. Accuracy of area measurements made from MR images compared with computed tomography. J Comput Assist Tomogr 1986;10:96-102.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 96-102
    • Zhu, X.1    Checkley, D.2    Hickey, D.3    Isherwood, I.4
  • 12
    • 0018304875 scopus 로고
    • The effect of computed tomography viewer controls on anatomical measurements
    • Koehler P, Anderson R, Baxter B. The effect of computed tomography viewer controls on anatomical measurements. Radiology 1979;130:189-194.
    • (1979) Radiology , vol.130 , pp. 189-194
    • Koehler, P.1    Anderson, R.2    Baxter, B.3
  • 14
    • 0029227666 scopus 로고
    • Qualitative assessment of femoral stem fit and fill using computed tomography and image processing
    • Rho JY, Feng Z, Ziv I. Qualitative assessment of femoral stem fit and fill using computed tomography and image processing. Proceedings of the American Society of Mechanical Engineering 1995;29:557-558.
    • (1995) Proceedings of the American Society of Mechanical Engineering , vol.29 , pp. 557-558
    • Rho, J.Y.1    Feng, Z.2    Ziv, I.3
  • 15
    • 0028296614 scopus 로고
    • Analysis of periprosthetic tissue formation around a porous titanium endoprosthesis using CT-based spatial reconstruction
    • Young DR, Robb RA, Rock MG, Chao EYS. Analysis of periprosthetic tissue formation around a porous titanium endoprosthesis using CT-based spatial reconstruction. J Comput Assist Tomogr 1994;18:461-468.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 461-468
    • Young, D.R.1    Robb, R.A.2    Rock, M.G.3    Chao, E.Y.S.4
  • 16
    • 0024951130 scopus 로고
    • Fit the patient to the prosthesis: An argument against the routine use of custom hip implants
    • Capello WN. Fit the patient to the prosthesis: An argument against the routine use of custom hip implants. Clin Orthop 1989;249: 56-59.
    • (1989) Clin Orthop , vol.249 , pp. 56-59
    • Capello, W.N.1
  • 17
    • 0346109835 scopus 로고
    • Biometry using computed tomography: A phantom study
    • Spoor CF, Zonneveld FW. Biometry using computed tomography: A phantom study. Eur J Morphol 1991;29:116-121.
    • (1991) Eur J Morphol , vol.29 , pp. 116-121
    • Spoor, C.F.1    Zonneveld, F.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.