메뉴 건너뛰기




Volumn 24, Issue 2, 1996, Pages 154-163

Anaesthetic machine and breathing system contamination and the efficiacy of bacterial/viral filters

Author keywords

Equipment: anaesthesia machine, filters, bacterial, viral

Indexed keywords

ANESTHETIC EQUIPMENT; BACTERIUM CONTAMINATION; BREATHING APPARATUS; CONFERENCE PAPER; CONTAMINATION; CROSS INFECTION; FILTER; MORBIDITY;

EID: 0029928139     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x9602400204     Document Type: Conference Paper
Times cited : (23)

References (74)
  • 1
    • 0002245246 scopus 로고
    • Investigation of possible patient-to-patient transmission of Hepatis C in a hospital
    • Chant K, Kociuba K, Munro R, et al. Investigation of possible patient-to-patient transmission of Hepatis C in a hospital. New South Wales Public Health Bulletin 1994; 5:47-51.
    • (1994) New South Wales Public Health Bulletin , vol.5 , pp. 47-51
    • Chant, K.1    Kociuba, K.2    Munro, R.3
  • 2
    • 15844392636 scopus 로고
    • Method for preventing cross-infection with gas machines
    • Magath T. Method for preventing cross-infection with gas machines. Anesth Analg 1938; 17:215-217.
    • (1938) Anesth Analg , vol.17 , pp. 215-217
    • Magath, T.1
  • 3
    • 0027177350 scopus 로고
    • Bacterial filters protect anaesthetic equipment in a low flow system
    • Luttropp H, Berntmann NL. Bacterial filters protect anaesthetic equipment in a low flow system. Anaesthesia 1993; 48:520-523.
    • (1993) Anaesthesia , vol.48 , pp. 520-523
    • Luttropp, H.1    Berntmann, N.L.2
  • 4
    • 0015115785 scopus 로고
    • Prevention of contamination of the circle system and ventilators with a new disposable filter
    • Shiotani G, Nicholes P, Ballinger C, Shaw L. Prevention of contamination of the circle system and ventilators with a new disposable filter. Anesth Analg 1971; 50:844-855.
    • (1971) Anesth Analg , vol.50 , pp. 844-855
    • Shiotani, G.1    Nicholes, P.2    Ballinger, C.3    Shaw, L.4
  • 5
    • 0017647284 scopus 로고
    • The anesthesia machine and circle system are not likely to be sources of bacterial contamination
    • du Moulin G, Saubermann A. The anesthesia machine and circle system are not likely to be sources of bacterial contamination. Anesthesiology 1977; 47:353-358.
    • (1977) Anesthesiology , vol.47 , pp. 353-358
    • Du Moulin, G.1    Saubermann, A.2
  • 7
    • 0026714720 scopus 로고
    • Contamination of anaesthetic tubing - A real hazard?
    • Ibrahim J, Perceval A. Contamination of anaesthetic tubing - A real hazard? Anaesth Intens Care 1992; 20:317-321.
    • (1992) Anaesth Intens Care , vol.20 , pp. 317-321
    • Ibrahim, J.1    Perceval, A.2
  • 8
    • 33751003284 scopus 로고
    • The numbers and the sites of origin of the droplets expelled during respiratory activities
    • Duigood JP. The numbers and the sites of origin of the droplets expelled during respiratory activities. Edinburgh Med J 1945; 52:385-401.
    • (1945) Edinburgh Med J , vol.52 , pp. 385-401
    • Duigood, J.P.1
  • 10
    • 0008393070 scopus 로고
    • Expulsion of pathogenic organisms from the respiratory tract
    • Duigood JP. Expulsion of pathogenic organisms from the respiratory tract. Br Med J 1946; 1:265-268.
    • (1946) Br Med J , vol.1 , pp. 265-268
    • Duigood, J.P.1
  • 11
    • 84965089512 scopus 로고
    • New sampler for the collection, sizing and enumeration of viable airborne particles
    • Andersen AA. New sampler for the collection, sizing and enumeration of viable airborne particles. J Bacteriol 1958; 76:471-484.
    • (1958) J Bacteriol , vol.76 , pp. 471-484
    • Andersen, A.A.1
  • 12
    • 0026029371 scopus 로고
    • Viability and distribution of bacteria after passage through a circle anaesthetic system
    • Murphy P, Fitzgeorge R, Barrett R. Viability and distribution of bacteria after passage through a circle anaesthetic system. Br J Anaesth 1991; 66:300-304.
    • (1991) Br J Anaesth , vol.66 , pp. 300-304
    • Murphy, P.1    Fitzgeorge, R.2    Barrett, R.3
  • 13
    • 0026750227 scopus 로고
    • Bacterial contamination and the effect of filters in anaesthetic circuits in a simulated patient model
    • Leitjen D, Rejger V, Mouton R. Bacterial contamination and the effect of filters in anaesthetic circuits in a simulated patient model. J Hospital Infection 1992; 24:51-60.
    • (1992) J Hospital Infection , vol.24 , pp. 51-60
    • Leitjen, D.1    Rejger, V.2    Mouton, R.3
  • 14
    • 0042064024 scopus 로고
    • Disinfection of anaesthetic face masks
    • MacCallum F, Noble W. Disinfection of anaesthetic face masks. Anaesthesia 1960; 15:307.
    • (1960) Anaesthesia , vol.15 , pp. 307
    • MacCallum, F.1    Noble, W.2
  • 15
    • 0014149542 scopus 로고
    • Risk of cross infection from inhalation anaesthetic equipment
    • Pandit S, Mehta S, Agarwal S. Risk of cross infection from inhalation anaesthetic equipment. Br J Anaesth 1967; 39:838-844.
    • (1967) Br J Anaesth , vol.39 , pp. 838-844
    • Pandit, S.1    Mehta, S.2    Agarwal, S.3
  • 16
    • 13144279028 scopus 로고
    • Sterilisation of anaesthetic equipment
    • Jenkins J, Edgar W. Sterilisation of anaesthetic equipment Anaesthesia 1964; 19:197-198.
    • (1964) Anaesthesia , vol.19 , pp. 197-198
    • Jenkins, J.1    Edgar, W.2
  • 17
    • 0023299905 scopus 로고
    • Nosocomial pneumonia in the intubated patient
    • Craven D, Driks M. Nosocomial pneumonia in the intubated patient Seminars Respir Infect 1987; 2:20-30.
    • (1987) Seminars Respir Infect , vol.2 , pp. 20-30
    • Craven, D.1    Driks, M.2
  • 18
    • 0020584862 scopus 로고
    • Direct dilution sampling, quantitation and microbial assessment of open-system ventilation circuits in Intensive Care Units
    • Malecka-Griggs B, Reinhardt D. Direct dilution sampling, quantitation and microbial assessment of open-system ventilation circuits in Intensive Care Units. J Clin Microbiol 1983; 17:870-877.
    • (1983) J Clin Microbiol , vol.17 , pp. 870-877
    • Malecka-Griggs, B.1    Reinhardt, D.2
  • 19
    • 0021275019 scopus 로고
    • Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia?
    • Craven D, Goularte T, Make B. Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia? Am Rev Resp Dis 1984; 129:825-828.
    • (1984) Am Rev Resp Dis , vol.129 , pp. 825-828
    • Craven, D.1    Goularte, T.2    Make, B.3
  • 20
    • 0021647899 scopus 로고
    • Moisture exchangers do not prevent patient contamination of ventilators. A microbiological study
    • Bygdeman S, von Euler C, Nystrom B. Moisture exchangers do not prevent patient contamination of ventilators. A microbiological study. Acta Anaesth Scand 1984; 28:591-594.
    • (1984) Acta Anaesth Scand , vol.28 , pp. 591-594
    • Bygdeman, S.1    Von Euler, C.2    Nystrom, B.3
  • 21
    • 0018444811 scopus 로고
    • Bacterial output from three respiratory therapy humidifying devices
    • Vesley D, Anderson J, Halbert M, Wyman L. Bacterial output from three respiratory therapy humidifying devices. Resp Care 1979; 24:228.
    • (1979) Resp Care , vol.24 , pp. 228
    • Vesley, D.1    Anderson, J.2    Halbert, M.3    Wyman, L.4
  • 22
    • 0014905443 scopus 로고
    • Effects of atmospheric humidity and temperature on the survival of airborne flavobacterium
    • Ehrlich R, Miller S, Walker R. Effects of atmospheric humidity and temperature on the survival of airborne flavobacterium. Appl Microbiol 1970; 20:884-887.
    • (1970) Appl Microbiol , vol.20 , pp. 884-887
    • Ehrlich, R.1    Miller, S.2    Walker, R.3
  • 23
    • 0013950106 scopus 로고
    • Physiological responses of airborne bacteria to shifts in relative humidity
    • Hatch M, Dimmick R. Physiological responses of airborne bacteria to shifts in relative humidity. Bacteriol Rev 1966; 30:597-603.
    • (1966) Bacteriol Rev , vol.30 , pp. 597-603
    • Hatch, M.1    Dimmick, R.2
  • 24
    • 0242401098 scopus 로고
    • Factors affecting the viability of airborne bacteria. III. The role of bonded water and protein structure in the death of airborne cells
    • Webb S. Factors affecting the viability of airborne bacteria. III. The role of bonded water and protein structure in the death of airborne cells. Can J Microbiol 1960; 6:89-105.
    • (1960) Can J Microbiol , vol.6 , pp. 89-105
    • Webb, S.1
  • 25
    • 0019226720 scopus 로고
    • Physics of airborne particles and their deposition in the lung
    • Morrow P. Physics of airborne particles and their deposition in the lung. Ann NY Acad Sci 1980; 353:71-80.
    • (1980) Ann NY Acad Sci , vol.353 , pp. 71-80
    • Morrow, P.1
  • 26
    • 0020333006 scopus 로고
    • Bacterial interactions between anesthesiologists, their patients and equipment
    • du Moulin G, Hedley-Whyte J. Bacterial interactions between anesthesiologists, their patients and equipment. Anesthesiology 1982; 57:37-41.
    • (1982) Anesthesiology , vol.57 , pp. 37-41
    • Du Moulin, G.1    Hedley-Whyte, J.2
  • 27
    • 84942385213 scopus 로고
    • Disease transmission by inefficiently sanitised anesthetising apparatus
    • Joseph D. Disease transmission by inefficiently sanitised anesthetising apparatus. JAMA 1952; 149:1196-1198.
    • (1952) JAMA , vol.149 , pp. 1196-1198
    • Joseph, D.1
  • 28
    • 0003073819 scopus 로고
    • Anaesthetic machines and cross-infection
    • Stark D, Green C. Anaesthetic machines and cross-infection. Anaesthesia 1962; 17:12-20.
    • (1962) Anaesthesia , vol.17 , pp. 12-20
    • Stark, D.1    Green, C.2
  • 30
    • 0002429518 scopus 로고
    • Experimental studies on carbon dioxide absorbers for anesthesia
    • Adriani J, Rovenstine E. Experimental studies on carbon dioxide absorbers for anesthesia. Anesthesiology 1941; 2:1-19.
    • (1941) Anesthesiology , vol.2 , pp. 1-19
    • Adriani, J.1    Rovenstine, E.2
  • 32
    • 0020645370 scopus 로고
    • Alterations in influenza virus pulmonary pathology induced by diethyl ether, halothane, enflurane and pentobarbital anesthesia in mice
    • Knight P, Bedows E, Nahrwold M, Maassab H, Smitka C, Busch M. Alterations in influenza virus pulmonary pathology induced by diethyl ether, halothane, enflurane and pentobarbital anesthesia in mice. Anesthesiology 1988; 58:209-215.
    • (1988) Anesthesiology , vol.58 , pp. 209-215
    • Knight, P.1    Bedows, E.2    Nahrwold, M.3    Maassab, H.4    Smitka, C.5    Busch, M.6
  • 33
    • 0016367255 scopus 로고
    • The effect of volatile anaesthetics on common respiratory pathogens
    • Mehta S, Behr G, Kenyon D. The effect of volatile anaesthetics on common respiratory pathogens. Anaesthesia 1974; 29:280-289.
    • (1974) Anaesthesia , vol.29 , pp. 280-289
    • Mehta, S.1    Behr, G.2    Kenyon, D.3
  • 34
    • 0018365382 scopus 로고
    • Bactericidal effects of anesthetics
    • Johnson B, Eger E. Bactericidal effects of anesthetics. Anesth Analg 1979; 58:136-138.
    • (1979) Anesth Analg , vol.58 , pp. 136-138
    • Johnson, B.1    Eger, E.2
  • 35
    • 15844429990 scopus 로고
    • Low-flow anaesthesia does not increase the risk of microbial contamination through the circle absorber system
    • Bengston J, Brandberg A, Brinkhoff B, Sonander H, Stenqvist O. Low-flow anaesthesia does not increase the risk of microbial contamination through the circle absorber system. Acta Anaesth Scand 1987; 31:127-131.
    • (1987) Acta Anaesth Scand , vol.31 , pp. 127-131
    • Bengston, J.1    Brandberg, A.2    Brinkhoff, B.3    Sonander, H.4    Stenqvist, O.5
  • 36
    • 0013854148 scopus 로고
    • Pseudomonas aeruginosa cross-infection due to a contaminated respiratory apparatus
    • Phillips I, Spencer G. Pseudomonas aeruginosa cross-infection due to a contaminated respiratory apparatus. Lancet 1965; 2:1325-1327.
    • (1965) Lancet , vol.2 , pp. 1325-1327
    • Phillips, I.1    Spencer, G.2
  • 37
    • 0019416506 scopus 로고
    • Epidemiology and prevention of pseudomonas aeruginosa chest infection in an Intensive Care Unit
    • Seal D, Strangeways J. Epidemiology and prevention of pseudomonas aeruginosa chest infection in an Intensive Care Unit. Anaesth Intens Care 1981; 9:260-265.
    • (1981) Anaesth Intens Care , vol.9 , pp. 260-265
    • Seal, D.1    Strangeways, J.2
  • 38
    • 0019908915 scopus 로고
    • Unusual dissemination of pseudomonas by ventilators
    • Im S, Fung J, So S, Yu D. Unusual dissemination of pseudomonas by ventilators. Anaesthesia 1982; 37:1074-1077.
    • (1982) Anaesthesia , vol.37 , pp. 1074-1077
    • Im, S.1    Fung, J.2    So, S.3    Yu, D.4
  • 39
    • 0015322059 scopus 로고
    • Pseudomonas aeruginosa respiratory tract infection acquired from a contaminated anesthesia machine
    • Olds J, Kisch A, Eberle B. Wilson J. Pseudomonas aeruginosa respiratory tract infection acquired from a contaminated anesthesia machine. Am Rev Resp Dis 1972; 105:628-632.
    • (1972) Am Rev Resp Dis , vol.105 , pp. 628-632
    • Olds, J.1    Kisch, A.2    Eberle, B.3    Wilson, J.4
  • 40
    • 0018075809 scopus 로고
    • Bacterial contamination of anaesthetic equipment
    • Nielson H, Vasegaard M, Stokke D. Bacterial contamination of anaesthetic equipment Br J Anaesth 1978; 50:811-814.
    • (1978) Br J Anaesth , vol.50 , pp. 811-814
    • Nielson, H.1    Vasegaard, M.2    Stokke, D.3
  • 42
    • 0019570586 scopus 로고
    • Sterile anesthesia breathing circuits do not prevent postoperative pulmonary infection
    • Feeley TW, Hamilton WK, Xavier B, Moyers J, Eger E. Sterile anesthesia breathing circuits do not prevent postoperative pulmonary infection. Anesthesiology 1981; 54:369-372.
    • (1981) Anesthesiology , vol.54 , pp. 369-372
    • Feeley, T.W.1    Hamilton, W.K.2    Xavier, B.3    Moyers, J.4    Eger, E.5
  • 43
    • 0019509187 scopus 로고
    • Failure of bacterial filters to reduce the incidence of pneumonia after inhalation anesthesia
    • Garibaldi R, Britt M, Webster C, Pace N. Failure of bacterial filters to reduce the incidence of pneumonia after inhalation anesthesia. Anesthesiology 1981; 54:364-368.
    • (1981) Anesthesiology , vol.54 , pp. 364-368
    • Garibaldi, R.1    Britt, M.2    Webster, C.3    Pace, N.4
  • 44
    • 0015369982 scopus 로고
    • How far do bacteria travel from the exhalation valve of IPPV equipment?
    • Dyer E, Peterson D. How far do bacteria travel from the exhalation valve of IPPV equipment? Anesth Analg 1972; 51: 516-519.
    • (1972) Anesth Analg , vol.51 , pp. 516-519
    • Dyer, E.1    Peterson, D.2
  • 45
    • 0020619954 scopus 로고
    • The potential role of respiratory therapy equipment in cross infection
    • Christopher K, Saravolatz L, Bush T, Conway W. The potential role of respiratory therapy equipment in cross infection. Am Rev Resp Dis 1983; 128:271-275.
    • (1983) Am Rev Resp Dis , vol.128 , pp. 271-275
    • Christopher, K.1    Saravolatz, L.2    Bush, T.3    Conway, W.4
  • 46
    • 0025953534 scopus 로고
    • Surgical wound infection rate by wound class, operative procedure, and patient risk index
    • Culver DH, Horan TC, Gaynes RP, et al. Surgical wound infection rate by wound class, operative procedure, and patient risk index. Am J Med 1991; 91(3B):1525-1575.
    • (1991) Am J Med , vol.91 , Issue.3 B , pp. 1525-1575
    • Culver, D.H.1    Horan, T.C.2    Gaynes, R.P.3
  • 47
    • 0015965434 scopus 로고
    • Five year experience with the development of an individually clean anesthesia system
    • Albrecht W, Dryden G. Five year experience with the development of an individually clean anesthesia system. Anesth Analg 1974; 53:24-28.
    • (1974) Anesth Analg , vol.53 , pp. 24-28
    • Albrecht, W.1    Dryden, G.2
  • 48
    • 15844407769 scopus 로고
    • Studies on the experimental epidemiology of respiratory infections. VI. The relationship between dose of micro-organisms and subsequent infection or death of a host
    • Goldberg L, Watkins H, Dolmatz M. Studies on the experimental epidemiology of respiratory infections. VI. The relationship between dose of micro-organisms and subsequent infection or death of a host. J Infect Dis 1954; 94:9-21.
    • (1954) J Infect Dis , vol.94 , pp. 9-21
    • Goldberg, L.1    Watkins, H.2    Dolmatz, M.3
  • 49
    • 0016715913 scopus 로고
    • Immunodepression after major surgery in normal patients
    • Slade M, Simmons R, Yunis E, Greenberg L. Immunodepression after major surgery in normal patients. Surgery 1975; 78:363-372.
    • (1975) Surgery , vol.78 , pp. 363-372
    • Slade, M.1    Simmons, R.2    Yunis, E.3    Greenberg, L.4
  • 50
    • 0016343254 scopus 로고
    • Depression of immunological responses due to surgery
    • Cooper A, Irvine J, Turnbull A. Depression of immunological responses due to surgery. Immunology 1974; 27:395-399.
    • (1974) Immunology , vol.27 , pp. 395-399
    • Cooper, A.1    Irvine, J.2    Turnbull, A.3
  • 51
    • 15844418194 scopus 로고
    • The environment of endotracheal tubes: Role of tracheal tubes in the colonisation of the upper airway and development of pneumonia
    • HFK 310, Bureau of Medical Devices. Department of Health and Human Services, U.S.A
    • Hedley-White J, du Moulin G. The environment of endotracheal tubes: Role of tracheal tubes in the colonisation of the upper airway and development of pneumonia. Proceedings of the Workshop on Tracheal Tubes, HFK 310, Bureau of Medical Devices. Department of Health and Human Services, U.S.A 1982; pp. 91-102.
    • (1982) Proceedings of the Workshop on Tracheal Tubes , pp. 91-102
    • Hedley-White, J.1    Du Moulin, G.2
  • 52
    • 15844390518 scopus 로고
    • The use of an absolute filter to sterilise the inspiratory air during intermittent positive pressure respiration
    • Bishop C, Roper W, Williams S. The use of an absolute filter to sterilise the inspiratory air during intermittent positive pressure respiration. Br J Anaesth 1963; 35:32-34.
    • (1963) Br J Anaesth , vol.35 , pp. 32-34
    • Bishop, C.1    Roper, W.2    Williams, S.3
  • 55
    • 15844361838 scopus 로고
    • University of Barcelona, Faculty of Pharmacy, Microbiology Laboratory, January
    • Queralt M. Microbiological tests on the bact-trap filter. University of Barcelona, Faculty of Pharmacy, Microbiology Laboratory, January 1991.
    • (1991) Microbiological Tests on the Bact-trap Filter
    • Queralt, M.1
  • 56
    • 15844383014 scopus 로고
    • Long-term bacterial challenge test (48 h) of an Edith Flex HME/Engtrom Y-Filter in a test ventilation system simulating clinical conditions
    • Johansson N. Long-term bacterial challenge test (48 h) of an Edith Flex HME/Engtrom Y-Filter in a test ventilation system simulating clinical conditions. Engstrom Laboratory Report 1994; 4:1-3.
    • (1994) Engstrom Laboratory Report , vol.4 , pp. 1-3
    • Johansson, N.1
  • 57
  • 60
    • 15844411214 scopus 로고
    • Nelson Laboratories Inc, Salt Lake City, Utah, U.S.A. April
    • Virus Filtration Efficiency Laboratory No. 41960. Nelson Laboratories Inc, Salt Lake City, Utah, U.S.A. April 1992.
    • (1992) Virus Filtration Efficiency Laboratory No. 41960
  • 62
    • 0026710032 scopus 로고
    • Heat and moisture exchangers with bacterial filters: A laboratory evaluation
    • Mebius C. Heat and moisture exchangers with bacterial filters: A laboratory evaluation. Acta Anaesth Scand 1992; 36:572-576.
    • (1992) Acta Anaesth Scand , vol.36 , pp. 572-576
    • Mebius, C.1
  • 64
    • 0027968422 scopus 로고
    • Heat and moisture exchangers and breathing filters
    • Hedley R, Allt-Graham J. Heat and moisture exchangers and breathing filters. Br J Anaesth 1994; 73:227-236.
    • (1994) Br J Anaesth , vol.73 , pp. 227-236
    • Hedley, R.1    Allt-Graham, J.2
  • 65
    • 0026582722 scopus 로고
    • A comparison of filtration properties of heat and moisture exchangers
    • Hedley R, Allt-Graham J. A comparison of filtration properties of heat and moisture exchangers. Anaesthesia 1992; 47:414-420.
    • (1992) Anaesthesia , vol.47 , pp. 414-420
    • Hedley, R.1    Allt-Graham, J.2
  • 66
    • 0026485258 scopus 로고
    • Bacterial retention properties of heat and moisture exchange filters
    • Lee M, Ford J, Hunt P, Ireland D, Swanson P. Bacterial retention properties of heat and moisture exchange filters. Br J Anaesth 1992; 69:522-525.
    • (1992) Br J Anaesth , vol.69 , pp. 522-525
    • Lee, M.1    Ford, J.2    Hunt, P.3    Ireland, D.4    Swanson, P.5
  • 67
    • 15844398538 scopus 로고
    • Anesthesia machine contamination
    • Brooks J, Gupta B, Baker D. Anesthesia machine contamination. Anesthesiology 1991; 75(Suppl):A874.
    • (1991) Anesthesiology , vol.75 , Issue.SUPPL.
    • Brooks, J.1    Gupta, B.2    Baker, D.3
  • 68
    • 0021241622 scopus 로고
    • Increase in resistance of in-line breathing filters in humidified air
    • Buckley P. Increase in resistance of in-line breathing filters in humidified air. Br J Anaeth 1984; 56:637-43.
    • (1984) Br J Anaeth , vol.56 , pp. 637-643
    • Buckley, P.1
  • 69
    • 0025886985 scopus 로고
    • Bilateral tension pneumothorax due to defective anaesthesia breathing circuit filters
    • Smith C, Otworth D, Kaluszyk P. Bilateral tension pneumothorax due to defective anaesthesia breathing circuit filters. J Clin Anaesth 1991; 3:229-34.
    • (1991) J Clin Anaesth , vol.3 , pp. 229-234
    • Smith, C.1    Otworth, D.2    Kaluszyk, P.3
  • 70
    • 0027411628 scopus 로고
    • Bilateral tension pneumothorax caused by a blocked filter in the anesthesia breathing circuit
    • McEwan A, Dowell L, Karis J. Bilateral tension pneumothorax caused by a blocked filter in the anesthesia breathing circuit Anesth Analg 1993; 76:440-2.
    • (1993) Anesth Analg , vol.76 , pp. 440-442
    • McEwan, A.1    Dowell, L.2    Karis, J.3
  • 71
    • 0027232943 scopus 로고
    • Detection of expiratory antibacterial filter occlusion
    • Barton R. Detection of expiratory antibacterial filter occlusion. Anesth Analg 1993; 77:197.
    • (1993) Anesth Analg , vol.77 , pp. 197
    • Barton, R.1
  • 72
    • 15844376589 scopus 로고
    • Heat and moisture exchange filter obstruction
    • Australian Therapeutic Goods Administration. Heat and moisture exchange filter obstruction. Australian Therapeutic Device Bulletin 1990; 903:3.
    • (1990) Australian Therapeutic Device Bulletin , vol.903 , pp. 3
  • 73
    • 0019312384 scopus 로고
    • The gasline filter: A cause for hypoxia
    • Schwartz A, Howse J, Ellison N. The gasline filter: A cause for hypoxia. Anesth Analg 1980; 59:617-618.
    • (1980) Anesth Analg , vol.59 , pp. 617-618
    • Schwartz, A.1    Howse, J.2    Ellison, N.3
  • 74
    • 0017263815 scopus 로고
    • Obstruction of bacterial filters by edema fluid
    • Kopman A. Glaser L. Obstruction of bacterial filters by edema fluid. Anesthesiology 1976; 44:169-170.
    • (1976) Anesthesiology , vol.44 , pp. 169-170
    • Kopman, A.1    Glaser, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.