메뉴 건너뛰기




Volumn 14, Issue 4, 1996, Pages 367-373

Liquid fixation of endometrial brush cytology ensures a well-preserved, representative cell sample with frequent tissue correlation

Author keywords

Cytology fixatives; Endometrial cytology; Endometrium

Indexed keywords

ARTICLE; CYTODIAGNOSIS; DIAGNOSTIC ACCURACY; ENDOMETRIUM CARCINOMA; ENDOMETRIUM CYTOLOGY; ENDOMETRIUM HYPERPLASIA; FEMALE; HISTOLOGY; HUMAN; HUMAN CELL; HUMAN TISSUE; HYSTERECTOMY; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; TISSUE FIXATION; TISSUE PREPARATION;

EID: 0029922804     PISSN: 87551039     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0339(199605)14:4<367::AID-DC16>3.0.CO;2-I     Document Type: Article
Times cited : (30)

References (8)
  • 3
    • 0027478306 scopus 로고
    • A comparison of the Pipelle device and the Vabra aspirator as measured by endometrial denudation in hysterectomy specimens: The Pipelle device samples significantly less of the endometrial surface than the Vabra aspirator
    • Rodriguez GC, Yaqub N, King ME. A comparison of the Pipelle device and the Vabra aspirator as measured by endometrial denudation in hysterectomy specimens: the Pipelle device samples significantly less of the endometrial surface than the Vabra aspirator. Am J Obstet Gynecol 1993;168.55-59.
    • (1993) Am J Obstet Gynecol , vol.168 , pp. 55-59
    • Rodriguez, G.C.1    Yaqub, N.2    King, M.E.3
  • 4
    • 0027323337 scopus 로고
    • Evaluation of endometrial biopsy using an aspiration curet without cervical tenaculum
    • Meeks GR, Woodliff JM, Box ST, Cesare CD. Evaluation of endometrial biopsy using an aspiration curet without cervical tenaculum. South Med J 1993;86:1011-1016
    • (1993) South Med J , vol.86 , pp. 1011-1016
    • Meeks, G.R.1    Woodliff, J.M.2    Box, S.T.3    Cesare, C.D.4
  • 5
    • 0028197495 scopus 로고
    • Histopathologic adequacy of office endometrial biopsies taken with the Z-sampler and Novak curette in premenopausal and postmenopausal women
    • Larson DM, Broste SK. Histopathologic adequacy of office endometrial biopsies taken with the Z-sampler and Novak curette in premenopausal and postmenopausal women. J Reprod Med 1994; 39:300-303.
    • (1994) J Reprod Med , vol.39 , pp. 300-303
    • Larson, D.M.1    Broste, S.K.2
  • 7
    • 0027417184 scopus 로고
    • The efficacy of the Pipelle endometrial biopsy in detecting endometrial carcinoma
    • Ferry J, Farnsworth A, Webster M, Wren B. The efficacy of the Pipelle endometrial biopsy in detecting endometrial carcinoma. Aust N Z J Obstet Gynaecol 1993;33:76-78.
    • (1993) Aust N Z J Obstet Gynaecol , vol.33 , pp. 76-78
    • Ferry, J.1    Farnsworth, A.2    Webster, M.3    Wren, B.4
  • 8
    • 0027380651 scopus 로고
    • The accuracy of endometrial Pipelle sampling with and without sonographic measurement of endometrial thickness
    • Goldchmit R, Katz Z, Blickstein I, Caspi B, Dgani R. The accuracy of endometrial Pipelle sampling with and without sonographic measurement of endometrial thickness. Obstet Gynecol 1993;82: 727-730.
    • (1993) Obstet Gynecol , vol.82 , pp. 727-730
    • Goldchmit, R.1    Katz, Z.2    Blickstein, I.3    Caspi, B.4    Dgani, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.