메뉴 건너뛰기




Volumn 63, Issue 2, 1996, Pages 105-111

Optimisation of monitor weighting factors for the estimation of effective dose equivalent from external photon exposures

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; CALIBRATION; DOSIMETER; DOSIMETRY; LIGHT EXPOSURE; PERSONNEL RADIATION MONITORING; PHANTOM; PHOTON; RADIATION EXPOSURE;

EID: 0029922422     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031516     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 0346824217 scopus 로고
    • Title 10. Code of Federal Regulations Part 20
    • US Nuclear Regulatory Commission. Standards for Protection against Radiation. Title 10. Code of Federal Regulations Part 20 (1992).
    • (1992) Standards for Protection Against Radiation
  • 2
    • 0003323262 scopus 로고
    • Recommendations of the International Commission on Radiological Protection
    • (Oxford: Pergamon Press) ICRP Publication 26
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. (Oxford: Pergamon Press) ICRP Publication 26, Ann. ICRP 1(3) 1-53 (1977).
    • (1977) Ann. ICRP , vol.1 , Issue.3 , pp. 1-53
  • 3
    • 0025890042 scopus 로고
    • Estimation of Effective Dose Equivalent Using Individual Dosemeters
    • Lakshmanan, A. R., Kher, R. K. and Supe, S. J. Estimation of Effective Dose Equivalent Using Individual Dosemeters. Radiat. Prot. Dosim. 35(4). 247-252 (1991).
    • (1991) Radiat. Prot. Dosim. , vol.35 , Issue.4 , pp. 247-252
    • Lakshmanan, A.R.1    Kher, R.K.2    Supe, S.J.3
  • 5
    • 0025930020 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection
    • (Oxford: Pergamon Press) ICRP Publication 60.
    • International Commission on Radiological Protection. 1990 Recommendations of the International Commission on Radiological Protection (Oxford: Pergamon Press) ICRP Publication 60. Ann. ICRP 16(1) (1991).
    • (1991) Ann. ICRP , vol.16 , Issue.1
  • 6
    • 0003884120 scopus 로고
    • Measurements of Dose Equivalents from External Photon and Electron Radiations
    • Bethesda, MD:ICRU
    • International Commission on Radiation Units and Measurements. Measurements of Dose Equivalents from External Photon and Electron Radiations (Bethesda, MD:ICRU) ICRU Report 47 (1992).
    • (1992) ICRU Report , vol.47
  • 7
    • 3142629648 scopus 로고    scopus 로고
    • Quantities and Units in Radiation Protection Dosimetry
    • Bethesda, MD: ICRU
    • International Commission on Radiation Units and Measurements. Quantities and Units in Radiation Protection Dosimetry (Bethesda, MD: ICRU) ICRU Report 51 (1993).
    • ICRU Report , vol.51 , pp. 1993
  • 8
    • 0003619963 scopus 로고
    • (Oxford: Pergamon Press) ICRP Publication 51
    • International Commission on Radiological Protection. Data for Use in Protection Against External Radiation (Oxford: Pergamon Press) ICRP Publication 51 (1987)
    • (1987) Data for Use in Protection Against External Radiation
  • 10
    • 0025753347 scopus 로고
    • The Angular Dependence and Irradiation Geometry Factor for the Dose Equivalent for Photons in Slab Phantoms of Tissue-equivalent Material and PMMA
    • Grosswendt, B. The Angular Dependence and Irradiation Geometry Factor for the Dose Equivalent for Photons in Slab Phantoms of Tissue-equivalent Material and PMMA. Radiat. Prot. Dosim. 35, 221-235 (1991).
    • (1991) Radiat. Prot. Dosim. , vol.35 , pp. 221-235
    • Grosswendt, B.1
  • 11
    • 0025812688 scopus 로고
    • Measurement of Conversion Coefficients for Calibrating Individual Dosemeters with Respect to the Operational Dose Equivalent Quantities on the PMMA Slab Phantom
    • Will, W. Measurement of Conversion Coefficients for Calibrating Individual Dosemeters with Respect to the Operational Dose Equivalent Quantities on the PMMA Slab Phantom. Radiat. Prot. Dosim. 37, 79-84 (1991).
    • (1991) Radiat. Prot. Dosim. , vol.37 , pp. 79-84
    • Will, W.1
  • 12
    • 3142522900 scopus 로고
    • Minimal Impact of Energy Spectral Width on Effective Dose Equivalent from Low-energy Photons
    • Claycamp, H. G Minimal Impact of Energy Spectral Width on Effective Dose Equivalent from Low-energy Photons. Radiat. Prot. Manage. 10, 51-58 (1993).
    • (1993) Radiat. Prot. Manage. , vol.10 , pp. 51-58
    • Claycamp, H.G.1
  • 13
    • 0019629520 scopus 로고
    • Effect of the Irradiation Geometry on Dosf-Equivalent Index
    • Grosswendt, B. and Hohlfeld, K. Effect of the Irradiation Geometry on Dosf-Equivalent Index. Health Phys. 41, 657-662 (1981).
    • (1981) Health Phys. , vol.41 , pp. 657-662
    • Grosswendt, B.1    Hohlfeld, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.