Volumn 19, Issue 11 II, 1996, Pages 1682-1688

Is local myocardial contractility related to endocardial acceleration signals detected by a transvenous pacing lead?

Author keywords

endocardial acceleration; rate responsive pacing; sensors

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; ENDOCARDIUM; FEMALE; HEART ATRIUM FIBRILLATION; HEART CATHETERIZATION; HEART MUSCLE CONTRACTILITY; HEART PACING; HEMODYNAMICS; HUMAN; MALE; SENSOR; SIGNAL DETECTION; SINUS RHYTHM; TRANSDUCER;

EID: 0029919378     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03206.x     Document Type: Article
Times cited : (30)

References (7)
  • 1
    • 0025733524 scopus 로고
    • Impedance measurements in the human right ventricle using a new pacing system
    • Wortel HJJ, Ruiter JH, De Boer HGA, et al. Impedance measurements in the human right ventricle using a new pacing system. PACE 1991; 14: 1336-1342.
    • (1991) PACE , vol.14 , pp. 1336-1342
    • Wortel, H.J.J.1    Ruiter, J.H.2    De Boer, H.G.A.3
  • 2
    • 0000040245 scopus 로고
    • Clinical experience with VVIR pacing based on right ventricular dP/dt
    • Heynen H, Sharma A, Sutton R, et al. Clinical experience with VVIR pacing based on right ventricular dP/dt. Eur JCPE 1991; l:138-146.
    • (1991) Eur JCPE , vol.50 , pp. 138-146
    • Heynen, H.1    Sharma, A.2    Sutton, R.3
  • 3
    • 0027933582 scopus 로고
    • Rate modulated pacing based on right ventricular dP/dt: Quantitative analysis of chronotropic response
    • Kay GN, Philippon F, Bubien RS, et al. Rate modulated pacing based on right ventricular dP/dt: Quantitative analysis of chronotropic response. PACE 1994; 17:1344-1354.
    • (1994) PACE , vol.17 , pp. 1344-1354
    • Kay, G.N.1    Philippon, F.2    Bubien, R.S.3
  • 4
    • 0024273217 scopus 로고
    • Physiological principles of a new method for rate responsive pacing using the preejection interval
    • Chirife R. Physiological principles of a new method for rate responsive pacing using the preejection interval. PACE 1988; 11:1545-1554.
    • (1988) PACE , vol.11 , pp. 1545-1554
    • Chirife, R.1
  • 5
    • 10544243018 scopus 로고
    • Evaluation of a new version of an adaptive-rate pacemaker controlled by pre-ejection period
    • Chirife R, Salazar AL, Ortega DF. Evaluation of a new version of an adaptive-rate pacemaker controlled by pre-ejection period. (abstract) Eur JCPE 1992; 2(Suppl. 1A):48.
    • (1992) Eur JCPE , vol.2 , Issue.SUPPL. 1A , pp. 48
    • Chirife, R.1    Salazar, A.L.2    Ortega, D.F.3
  • 6
    • 0040728673 scopus 로고
    • Implantable radiotelemetry system (I.R.S.) for peak endocardial acceleration (P.E.A.) measurements on free sheep
    • Parlapiano M, Bizzini A, Corbucci G, et al. Implantable radiotelemetry system (I.R.S.) for peak endocardial acceleration (P.E.A.) measurements on free sheep, (abstract) Eur JCPE 1994; 4(Suppl 4):60.
    • (1994) Eur JCPE , vol.4 , Issue.4 SUPPL. , pp. 60
    • Parlapiano, M.1    Bizzini, A.2    Corbucci, G.3
  • 7
    • 0028786174 scopus 로고
    • Experience with a new myocardial acceleration sensor during dobutamine infusion and exercise test
    • Occhetta E, Perucca A, Rognoni G, et al. Experience with a new myocardial acceleration sensor during dobutamine infusion and exercise test. Eur JCPE 1995; 5:204-209.
    • (1995) Eur JCPE , vol.5 , pp. 204-209
    • Occhetta, E.1    Perucca, A.2    Rognoni, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.