메뉴 건너뛰기




Volumn 27, Issue 4, 1996, Pages 479-484

Forced air speeds rewarming in accidental hypothermia

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AIRFLOW; AIRWAY; ARTICLE; BODY TEMPERATURE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORE TEMPERATURE; DEATH; HUMAN; HYPOTENSION; HYPOTHERMIA; INJURY; PRIORITY JOURNAL; TREATMENT OUTCOME; WARMING;

EID: 0029913414     PISSN: 01960644     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0196-0644(96)70237-8     Document Type: Article
Times cited : (104)

References (36)
  • 2
    • 0023051589 scopus 로고
    • Hypothermia-associated death: United States, 1968-1980 JAMA 255 1986 304 311
    • (1986) JAMA , vol.255 , pp. 304-311
  • 3
    • 0027908142 scopus 로고
    • Hypothermia-related deaths: Cook County, Illinois, November 1992-March 1993 Morbid Mortal Wkly Rep 42 1993 917 919
    • (1993) Morbid Mortal Wkly Rep , vol.42 , pp. 917-919
  • 4
    • 0021015488 scopus 로고
    • Accidental hypothermia
    • BC Paton Accidental hypothermia Pharmacol Ther 22 1983 331 377
    • (1983) Pharmacol Ther , vol.22 , pp. 331-377
    • Paton, BC1
  • 5
    • 0018821427 scopus 로고
    • Central rewarming system for treatment of hypothermia
    • IM Ledingham IH Douglas GS Routh Central rewarming system for treatment of hypothermia Lancet 1 1980 1168 1169
    • (1980) Lancet , vol.1 , pp. 1168-1169
    • Ledingham, IM1    Douglas, IH2    Routh, GS3
  • 6
    • 0018177732 scopus 로고
    • Hypothermia: Pathophysiology, clinical settings, and management
    • JB Reuler Hypothermia: Pathophysiology, clinical settings, and management Ann Intern Med 89 1978 519 527
    • (1978) Ann Intern Med , vol.89 , pp. 519-527
    • Reuler, JB1
  • 7
    • 0024988975 scopus 로고
    • Skin-surface warming: Heat flux and central temperature
    • DI Sessler A Moayeri Skin-surface warming: Heat flux and central temperature Anesthesiology 73 1990 218 224
    • (1990) Anesthesiology , vol.73 , pp. 218-224
    • Sessler, DI1    Moayeri, A2
  • 8
    • 0028270092 scopus 로고
    • Comparison of forced-air patient warming systems for perioperative use
    • GG Giesbrecht MB Ducharme JP McGuire Comparison of forced-air patient warming systems for perioperative use Anesthesiology 80 1994 671 679
    • (1994) Anesthesiology , vol.80 , pp. 671-679
    • Giesbrecht, GG1    Ducharme, MB2    McGuire, JP3
  • 9
    • 0026498659 scopus 로고
    • Intraoperative warming therapies: A comparison of three devices
    • J Hynson DI Sessler Intraoperative warming therapies: A comparison of three devices J Clin Anesth 4 1992 194 199
    • (1992) J Clin Anesth , vol.4 , pp. 194-199
    • Hynson, J1    Sessler, DI2
  • 10
    • 0027174995 scopus 로고
    • Forced-air warming maintains intraoperative normothermia better than circulating-water mattresses
    • A Kurz M Kurz G Poeschl Forced-air warming maintains intraoperative normothermia better than circulating-water mattresses Anesth Analg 77 1993 89 95
    • (1993) Anesth Analg , vol.77 , pp. 89-95
    • Kurz, A1    Kurz, M2    Poeschl, G3
  • 11
    • 0028106957 scopus 로고
    • Bair Hugger forced-air warming maintains normothermia more effectively than Thermo-Lite insulation
    • SF Borms SLE Engelen DGA Himpe Bair Hugger forced-air warming maintains normothermia more effectively than Thermo-Lite insulation J Clin Anesth 6 1994 303 307
    • (1994) J Clin Anesth , vol.6 , pp. 303-307
    • Borms, SF1    Engelen, SLE2    Himpe, DGA3
  • 12
    • 0028196547 scopus 로고
    • Leg temperature and heat content in humans during immersion hypothermia and rewarming
    • GK Bristow GG Giesbrecht DI Sessler Leg temperature and heat content in humans during immersion hypothermia and rewarming Aviat Space Environ Med 65 1994 220 226
    • (1994) Aviat Space Environ Med , vol.65 , pp. 220-226
    • Bristow, GK1    Giesbrecht, GG2    Sessler, DI3
  • 13
    • 0026673776 scopus 로고
    • A second postcooling afterdrop: More evidence for a convective mechanism
    • GG Giesbrecht GK Bristow A second postcooling afterdrop: More evidence for a convective mechanism J Appl Physiol 73 1992 1253 1258
    • (1992) J Appl Physiol , vol.73 , pp. 1253-1258
    • Giesbrecht, GG1    Bristow, GK2
  • 14
    • 0026442573 scopus 로고
    • Isolation of peripheral and central thermal compartments in vasoconstricted patients
    • MH Ereth R Lennon DI Sessler Isolation of peripheral and central thermal compartments in vasoconstricted patients Aviat Space Environ Med 63 1992 1065 1069
    • (1992) Aviat Space Environ Med , vol.63 , pp. 1065-1069
    • Ereth, MH1    Lennon, R2    Sessler, DI3
  • 15
    • 0027287804 scopus 로고
    • Heat loss in humans covered with cotton hospital blankets
    • DI Sessler M Schroeder Heat loss in humans covered with cotton hospital blankets Anesth Analg 77 1993 73 77
    • (1993) Anesth Analg , vol.77 , pp. 73-77
    • Sessler, DI1    Schroeder, M2
  • 16
    • 0022339891 scopus 로고
    • Controlled comparison of radiowave regional hypothermia and peritoneal lavage rewarming of immersion hypothermia
    • JD White AB Butterfield KA Greer Controlled comparison of radiowave regional hypothermia and peritoneal lavage rewarming of immersion hypothermia J Trauma 25 1985 989 993
    • (1985) J Trauma , vol.25 , pp. 989-993
    • White, JD1    Butterfield, AB2    Greer, KA3
  • 17
    • 0019187472 scopus 로고
    • Urban accidental hypothermia: 135 cases
    • JW Miller DF Danzl DM Thomas Urban accidental hypothermia: 135 cases Ann Emerg Med 9 1980 456 461
    • (1980) Ann Emerg Med , vol.9 , pp. 456-461
    • Miller, JW1    Danzl, DF2    Thomas, DM3
  • 18
    • 0025036663 scopus 로고
    • Treatment of moderate-to-severe hypothermia in an urban setting
    • CP Shields Treatment of moderate-to-severe hypothermia in an urban setting Ann Emerg Med 19 1980 1093 1097
    • (1980) Ann Emerg Med , vol.19 , pp. 1093-1097
    • Shields, CP1
  • 19
    • 0028631112 scopus 로고
    • Accidental hypothermia
    • DF Danzl RS. Pozos Accidental hypothermia N Engl J Med 331 1994 1756 1760
    • (1994) N Engl J Med , vol.331 , pp. 1756-1760
    • Danzl, DF1    Pozos, RS.2
  • 20
    • 0028241013 scopus 로고
    • Treatment of immersion hypothermia by direct body-to-body contact
    • GG Giesbrecht DI Sessler IB Mekjavic Treatment of immersion hypothermia by direct body-to-body contact J Appl Physiol 76 1994 2373 2379
    • (1994) J Appl Physiol , vol.76 , pp. 2373-2379
    • Giesbrecht, GG1    Sessler, DI2    Mekjavic, IB3
  • 21
    • 0027469941 scopus 로고
    • Thermoregulation and afterdrop during hypothermia in patients with poikilothermia
    • MA MacKenzie ARM Hermus HCH Wollersheim Thermoregulation and afterdrop during hypothermia in patients with poikilothermia Q J Med 86 1993 205 213
    • (1993) Q J Med , vol.86 , pp. 205-213
    • MacKenzie, MA1    Hermus, ARM2    Wollersheim, HCH3
  • 22
    • 0002124289 scopus 로고
    • Active neurogenic vasodilation in man
    • LB Rowell Active neurogenic vasodilation in man PM Vanhoutte I Leusen Vasodilation 1981 Raven Press New York 1 17
    • (1981) , pp. 1-17
    • Rowell, LB1
  • 23
    • 0021351113 scopus 로고
    • Thermal and cardiovascular changes during three models of resuscitation from mild hypothermia
    • JS Hayward JD Eckerson D Kemna Thermal and cardiovascular changes during three models of resuscitation from mild hypothermia Resuscitation 11 1984 21 33
    • (1984) Resuscitation , vol.11 , pp. 21-33
    • Hayward, JS1    Eckerson, JD2    Kemna, D3
  • 24
    • 0021926924 scopus 로고
    • Thermal injury caused by hot pack application in hypothermic children
    • KW Feldman JP Morray RT Schaller Thermal injury caused by hot pack application in hypothermic children Am J Emerg Med 3 1985 38 41
    • (1985) Am J Emerg Med , vol.3 , pp. 38-41
    • Feldman, KW1    Morray, JP2    Schaller, RT3
  • 25
    • 0028271535 scopus 로고
    • Burns from warming devices in anesthesia: A closed claims analysis
    • FW Cheney KL Posner RA Caplan Burns from warming devices in anesthesia: A closed claims analysis Anesthesiology 80 1994 806 810
    • (1994) Anesthesiology , vol.80 , pp. 806-810
    • Cheney, FW1    Posner, KL2    Caplan, RA3
  • 26
    • 0014241405 scopus 로고
    • Thermal burns caused by warming blankets in the operating room
    • MH Chino EL Nagel Thermal burns caused by warming blankets in the operating room Anesthesiology 29 1968 149 151
    • (1968) Anesthesiology , vol.29 , pp. 149-151
    • Chino, MH1    Nagel, EL2
  • 27
    • 0014056662 scopus 로고
    • Thermal blanket injury in the operating room
    • SM Scott NC Oteen Thermal blanket injury in the operating room Arch Surg 94 1967 181
    • (1967) Arch Surg , vol.94 , pp. 181
    • Scott, SM1    Oteen, NC2
  • 29
    • 0019971014 scopus 로고
    • Accidental hypothermia treated with rapid rewarming by immersion
    • L Zachary JO Kucan MC Robson Accidental hypothermia treated with rapid rewarming by immersion Ann Plastic Surg 9 1982 238 241
    • (1982) Ann Plastic Surg , vol.9 , pp. 238-241
    • Zachary, L1    Kucan, JO2    Robson, MC3
  • 30
    • 0015548976 scopus 로고
    • Accidental hypothermia treated by central rewarming through the airway
    • EL: Lloyd Accidental hypothermia treated by central rewarming through the airway Br J Anaesth 45 1973 41 48
    • (1973) Br J Anaesth , vol.45 , pp. 41-48
    • Lloyd, EL:1
  • 31
    • 0025933889 scopus 로고
    • Equipment for airway rewarming in the treatment of accidental hypothermia
    • EL Lloyd Equipment for airway rewarming in the treatment of accidental hypothermia J Wilderness Med 3 1991 330 350
    • (1991) J Wilderness Med , vol.3 , pp. 330-350
    • Lloyd, EL1
  • 32
    • 0025241207 scopus 로고
    • Efficiency of airway heat and moisture exchangers in anesthetized humans
    • P Bickler DI Sessler Efficiency of airway heat and moisture exchangers in anesthetized humans Anesth Analg 71 1990 415 418
    • (1990) Anesth Analg , vol.71 , pp. 415-418
    • Bickler, P1    Sessler, DI2
  • 33
    • 0020117780 scopus 로고
    • Paradoxical inhibition of decreases in body temperature by use of heated and humidified gases
    • HHL Hendrickx GE Trahey MP Argentieri Paradoxical inhibition of decreases in body temperature by use of heated and humidified gases (letter) Anesth Analg 61 1982 393 394
    • (1982) Anesth Analg , vol.61 , pp. 393-394
    • Hendrickx, HHL1    Trahey, GE2    Argentieri, MP3
  • 34
    • 0026594773 scopus 로고
    • Influence d'un filtre hygrophobe ou d'un humidificateur-réchauffeur sur l'hypothermie peropératoire
    • H Deriaz N Fiez A Lienhart Influence d'un filtre hygrophobe ou d'un humidificateur-réchauffeur sur l'hypothermie peropératoire Ann Fr Anesth Réanim 11 1992 145 149
    • (1992) Ann Fr Anesth Réanim , vol.11 , pp. 145-149
    • Deriaz, H1    Fiez, N2    Lienhart, A3
  • 35
    • 0025769408 scopus 로고
    • Efficacy and safety of prehospital rewarming techniques to treat accidental hypothermia
    • JA Sterba Efficacy and safety of prehospital rewarming techniques to treat accidental hypothermia Ann Emerg Med 20 1991 896 901
    • (1991) Ann Emerg Med , vol.20 , pp. 896-901
    • Sterba, JA1
  • 36
    • 0017736380 scopus 로고
    • Accidental hypothermia: An experimental study of practical rewarming methods
    • ML Collis AM Steinman RD Chaney Accidental hypothermia: An experimental study of practical rewarming methods Aviat Space Environ Med 48 1977 625 632
    • (1977) Aviat Space Environ Med , vol.48 , pp. 625-632
    • Collis, ML1    Steinman, AM2    Chaney, RD3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.