-
1
-
-
0021747298
-
Closed-loop glycemic control with a wearable type artificial pancreas, variations in daily insulin requirements to glycemic response
-
Shichiri M, Kawamori R, Hakui N, Yamasaki Y, A H : Closed-loop glycemic control with a wearable type artificial pancreas, variations in daily insulin requirements to glycemic response. Diabetes 33: 1200, 1984
-
(1984)
Diabetes
, vol.33
, pp. 1200
-
-
Shichiri, M.1
Kawamori, R.2
Hakui, N.3
Yamasaki, Y.4
H, A.5
-
2
-
-
0023615404
-
The development of artificial pancreas. From bed-side wearable-type to implantable one
-
Shichiri M, Kawamori R, Yamasaki Y : The development of artificial pancreas. From bed-side wearable-type to implantable one. Med Technol 12 39,1987
-
(1987)
Med Technol
, vol.12
, pp. 39
-
-
Shichiri, M.1
Kawamori, R.2
Yamasaki, Y.3
-
3
-
-
0026298988
-
An artificial endocrine pancreas : Problems awaiting solution for long term clinical applications of a glucose sensor
-
Shichiri M, Fukushima H, Sakakida M, Kajiwara K Hashiguchi Y : An artificial endocrine pancreas : Problems awaiting solution for long term clinical applications of a glucose sensor: Frontiers Med Bi Engng 3 : 283, 1991
-
(1991)
Frontiers Med Bi Engng
, vol.3
, pp. 283
-
-
Shichiri, M.1
Fukushima, H.2
Sakakida, M.3
Kajiwara, K.4
Hashiguchi, Y.5
-
4
-
-
0037502008
-
Development of ferrocene-mediated needle-type glucose sensor as a measure of true subcutaneous tissue glucose concentrations
-
Sakakida M, Ichinose K, Fukushima H, Nishida K, Kajiwara K, Hashiguchi Y, Taniguchi I, Shichiri M : Development of ferrocene-mediated needle-type glucose sensor as a measure of true subcutaneous tissue glucose concentrations. Artif Organs Today 2 : 145, 1992
-
(1992)
Artif Organs Today
, vol.2
, pp. 145
-
-
Sakakida, M.1
Ichinose, K.2
Fukushima, H.3
Nishida, K.4
Kajiwara, K.5
Hashiguchi, Y.6
Taniguchi, I.7
Shichiri, M.8
-
5
-
-
0028218970
-
Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method ; Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients
-
Hashiguchi Y, Sakakida M, Nishida K, Uemura T, Kakiwara K, Shichiri M : Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method ; Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients. Diabetes Care 17 : 387, 1994
-
(1994)
Diabetes Care
, vol.17
, pp. 387
-
-
Hashiguchi, Y.1
Sakakida, M.2
Nishida, K.3
Uemura, T.4
Kakiwara, K.5
Shichiri, M.6
-
6
-
-
0025229068
-
Preparation of phospholipid polymers and their properties as polymer hydrogel membranes
-
Ishihara K, Ueda T, Nakabayashi N. Preparation of phospholipid polymers and their properties as polymer hydrogel membranes, Polym J 1990 ; 22 : 355-360
-
(1990)
Polym J
, vol.22
, pp. 355-360
-
-
Ishihara, K.1
Ueda, T.2
Nakabayashi, N.3
-
7
-
-
0025472071
-
Reduced thrombogenicity of polymers having phospholipid polar groups
-
Ishihara K, Aragaki R, Ueda T, Watanabe A, Nakabayashi N : Reduced thrombogenicity of polymers having phospholipid polar groups, J Biomed Mater Res 24 : 1069,1990
-
(1990)
J Biomed Mater Res
, vol.24
, pp. 1069
-
-
Ishihara, K.1
Aragaki, R.2
Ueda, T.3
Watanabe, A.4
Nakabayashi, N.5
-
8
-
-
0027006792
-
Hemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism
-
Ishihara K, Oshida H, Endo Y, Ueda T, Watanabe A, Nakabayashi N : Hemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism. J Biomed Mater Res 26 : 1543, 1992
-
(1992)
J Biomed Mater Res
, vol.26
, pp. 1543
-
-
Ishihara, K.1
Oshida, H.2
Endo, Y.3
Ueda, T.4
Watanabe, A.5
Nakabayashi, N.6
-
9
-
-
0026592438
-
Improvement of blood compatibility on cellulose dialysis membrane 1, Grafting of 2-methacryloyloxyethyl phosphorylcholine on to a cellulose membrane surface
-
Ishihara K, Nakabayashi N, Fukumoto K, Aoki J : Improvement of blood compatibility on cellulose dialysis membrane 1, Grafting of 2-methacryloyloxyethyl phosphorylcholine on to a cellulose membrane surface. Biomaterials 13 : 145, 1992
-
(1992)
Biomaterials
, vol.13
, pp. 145
-
-
Ishihara, K.1
Nakabayashi, N.2
Fukumoto, K.3
Aoki, J.4
-
10
-
-
2242480239
-
-
Japanese source
-
-
-
-
11
-
-
0028019058
-
The "Ulm Zucker Uhr System" and its Consequence
-
Pfeiffer EF. : The "Ulm Zucker Uhr System" and its Consequence. Horm metab Res 26 : 510, 1991
-
(1991)
Horm Metab Res
, vol.26
, pp. 510
-
-
Pfeiffer, E.F.1
-
12
-
-
0029101233
-
Subcutaneous Glucose Concentration in Humans-Real estimation and continuous monitoring
-
Sternberg F, Meyerhoff C, Mennel FJ, Bischof F, Pfeiffer EF. : Subcutaneous Glucose Concentration in Humans-Real estimation and continuous monitoring Diabetes Care 48 : 1266, 1995
-
(1995)
Diabetes Care
, vol.48
, pp. 1266
-
-
Sternberg, F.1
Meyerhoff, C.2
Mennel, F.J.3
Bischof, F.4
Pfeiffer, E.F.5
|