Volumn 25, Issue 1, 1996, Pages 139-143

Development of a miniaturized glucose monitoring system combined a needle-type glucose sensor and a microdialysis hollow-fiber probe covered with a newly designed biocompatible membrane

Author keywords

Biocompatibility; Continuous Glucose Monitoring; Hollow Fiber; Microdialysis; Subcutaneous Tissue Glucose Concentration

Indexed keywords

GLUCOSE;

EID: 0029911729     PISSN: 03000818     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (12)
  • 1
    • 0021747298 scopus 로고
    • Closed-loop glycemic control with a wearable type artificial pancreas, variations in daily insulin requirements to glycemic response
    • Shichiri M, Kawamori R, Hakui N, Yamasaki Y, A H : Closed-loop glycemic control with a wearable type artificial pancreas, variations in daily insulin requirements to glycemic response. Diabetes 33: 1200, 1984
    • (1984) Diabetes , vol.33 , pp. 1200
    • Shichiri, M.1    Kawamori, R.2    Hakui, N.3    Yamasaki, Y.4    H, A.5
  • 2
    • 0023615404 scopus 로고
    • The development of artificial pancreas. From bed-side wearable-type to implantable one
    • Shichiri M, Kawamori R, Yamasaki Y : The development of artificial pancreas. From bed-side wearable-type to implantable one. Med Technol 12 39,1987
    • (1987) Med Technol , vol.12 , pp. 39
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3
  • 3
    • 0026298988 scopus 로고
    • An artificial endocrine pancreas : Problems awaiting solution for long term clinical applications of a glucose sensor
    • Shichiri M, Fukushima H, Sakakida M, Kajiwara K Hashiguchi Y : An artificial endocrine pancreas : Problems awaiting solution for long term clinical applications of a glucose sensor: Frontiers Med Bi Engng 3 : 283, 1991
    • (1991) Frontiers Med Bi Engng , vol.3 , pp. 283
    • Shichiri, M.1    Fukushima, H.2    Sakakida, M.3    Kajiwara, K.4    Hashiguchi, Y.5
  • 5
    • 0028218970 scopus 로고
    • Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method ; Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients
    • Hashiguchi Y, Sakakida M, Nishida K, Uemura T, Kakiwara K, Shichiri M : Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method ; Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients. Diabetes Care 17 : 387, 1994
    • (1994) Diabetes Care , vol.17 , pp. 387
    • Hashiguchi, Y.1    Sakakida, M.2    Nishida, K.3    Uemura, T.4    Kakiwara, K.5    Shichiri, M.6
  • 6
    • 0025229068 scopus 로고
    • Preparation of phospholipid polymers and their properties as polymer hydrogel membranes
    • Ishihara K, Ueda T, Nakabayashi N. Preparation of phospholipid polymers and their properties as polymer hydrogel membranes, Polym J 1990 ; 22 : 355-360
    • (1990) Polym J , vol.22 , pp. 355-360
    • Ishihara, K.1    Ueda, T.2    Nakabayashi, N.3
  • 8
    • 0027006792 scopus 로고
    • Hemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism
    • Ishihara K, Oshida H, Endo Y, Ueda T, Watanabe A, Nakabayashi N : Hemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism. J Biomed Mater Res 26 : 1543, 1992
    • (1992) J Biomed Mater Res , vol.26 , pp. 1543
    • Ishihara, K.1    Oshida, H.2    Endo, Y.3    Ueda, T.4    Watanabe, A.5    Nakabayashi, N.6
  • 9
    • 0026592438 scopus 로고
    • Improvement of blood compatibility on cellulose dialysis membrane 1, Grafting of 2-methacryloyloxyethyl phosphorylcholine on to a cellulose membrane surface
    • Ishihara K, Nakabayashi N, Fukumoto K, Aoki J : Improvement of blood compatibility on cellulose dialysis membrane 1, Grafting of 2-methacryloyloxyethyl phosphorylcholine on to a cellulose membrane surface. Biomaterials 13 : 145, 1992
    • (1992) Biomaterials , vol.13 , pp. 145
    • Ishihara, K.1    Nakabayashi, N.2    Fukumoto, K.3    Aoki, J.4
  • 10
    • 2242480239 scopus 로고    scopus 로고
    • Japanese source
  • 11
    • 0028019058 scopus 로고
    • The "Ulm Zucker Uhr System" and its Consequence
    • Pfeiffer EF. : The "Ulm Zucker Uhr System" and its Consequence. Horm metab Res 26 : 510, 1991
    • (1991) Horm Metab Res , vol.26 , pp. 510
    • Pfeiffer, E.F.1
  • 12
    • 0029101233 scopus 로고
    • Subcutaneous Glucose Concentration in Humans-Real estimation and continuous monitoring
    • Sternberg F, Meyerhoff C, Mennel FJ, Bischof F, Pfeiffer EF. : Subcutaneous Glucose Concentration in Humans-Real estimation and continuous monitoring Diabetes Care 48 : 1266, 1995
    • (1995) Diabetes Care , vol.48 , pp. 1266
    • Sternberg, F.1    Meyerhoff, C.2    Mennel, F.J.3    Bischof, F.4    Pfeiffer, E.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.