Volumn 19, Issue 11 II, 1996, Pages 1758-1763

Single lead DDD system: A comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds

Author keywords

DDD pacing; floating atrial electrode; single pass lead

Indexed keywords

AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL PROTOCOL; CLINICAL TRIAL; COMPLETE HEART BLOCK; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAPHRAGM; FEMALE; HEART ATRIUM FIBRILLATION; HEART ATRIUM PACEMAKER; HEART ATRIUM PACING; HUMAN; MALE; P WAVE; PACEMAKER ELECTRODE; RANDOMIZED CONTROLLED TRIAL; SENSOR;

EID: 0029907771     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03219.x     Document Type: Article
Times cited : (23)

References (6)
  • 1
    • 0028089781 scopus 로고
    • Long-term reliability of single lead atrial synchronous pacing systems using closely spaced atrial dipoles: Five-year experience
    • Ansani L, Percoco GF, Guardigli G, et al. Long-term reliability of single lead atrial synchronous pacing systems using closely spaced atrial dipoles: Five-year experience. PACE 1994; 17:1865-1869.
    • (1994) PACE , vol.17 , pp. 1865-1869
    • Ansani, L.1    Percoco, G.F.2    Guardigli, G.3
  • 2
    • 0043207770 scopus 로고
    • Clinical experience with the first single lead VDDR pacemaker
    • Lau CP, Tai YT, Li JPS, et al. Clinical experience with the first single lead VDDR pacemaker. PACE 1993; 15:1094-1100.
    • (1993) PACE , vol.15 , pp. 1094-1100
    • Lau, C.P.1    Tai, Y.T.2    Li, J.P.S.3
  • 3
    • 0028027767 scopus 로고
    • Long term stability of P wave sensing in single lead VDDR pacing: Clinical versus subclinical atrial undersensing
    • Lau CP, Tai YT, Leung SK, et al. Long term stability of P wave sensing in single lead VDDR pacing: Clinical versus subclinical atrial undersensing. PACE 1994; 17:1849-1853.
    • (1994) PACE , vol.17 , pp. 1849-1853
    • Lau, C.P.1    Tai, Y.T.2    Leung, S.K.3
  • 4
    • 0029999531 scopus 로고    scopus 로고
    • Comparative evaluation of acute and long term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemaker: Diagonally-arranged bipolar versus closely-spaced bipolar ring electrodes
    • In press
    • Lau CP, Leung SK, Lee ISF. Comparative evaluation of acute and long term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemaker: Diagonally-arranged bipolar versus closely-spaced bipolar ring electrodes. PACE 1996; (In press).
    • (1996) PACE
    • Lau, C.P.1    Leung, S.K.2    Lee, I.S.F.3
  • 5
    • 0028097034 scopus 로고
    • A new dual chamber single lead system
    • Hirschberg J, Ekwall C, Strandberg H, et al. A new dual chamber single lead system. PACE 1994; 17: 1870-1872.
    • (1994) PACE , vol.17 , pp. 1870-1872
    • Hirschberg, J.1    Ekwall, C.2    Strandberg, H.3
  • 6
    • 0009615660 scopus 로고
    • Overlapping biphasic stimulation: A novel pacing mode with low capture thresholds
    • Hartung WM, Hidden-Lucet F, McTeague K, et al. Overlapping biphasic stimulation: A novel pacing mode with low capture thresholds. (Abstract). Circulation 1994; 90:69.
    • (1994) Circulation , vol.90 , pp. 69
    • Hartung, W.M.1    Hidden-Lucet, F.2    McTeague, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.