메뉴 건너뛰기




Volumn 167, Issue 5, 1996, Pages 1267-1269

Wire fragments after needle localization

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BREAST BIOPSY; BREAST DISEASE; CANCER SCREENING; CLINICAL ARTICLE; EXCISION; FEMALE; FOLLOW UP; FOREIGN BODY; GUIDE WIRE; HUMAN; MAMMOGRAPHY; NEEDLE; PRIORITY JOURNAL; TREATMENT PLANNING;

EID: 0029907234     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.167.5.8911193     Document Type: Article
Times cited : (40)

References (12)
  • 1
    • 0021238129 scopus 로고
    • Prebiopsy localization of nonpalpable breast lesions
    • Gisvold JJ, Martin JK Jr. Prebiopsy localization of nonpalpable breast lesions. AJR 1984;143: 477-481
    • (1984) AJR , vol.143 , pp. 477-481
    • Gisvold, J.J.1    Martin Jr., J.K.2
  • 2
    • 0024076140 scopus 로고
    • Migration of breast biopsy localization wire
    • Kopans DB. Migration of breast biopsy localization wire (letter). AJR 1988;151:614-615
    • (1988) AJR , vol.151 , pp. 614-615
    • Kopans, D.B.1
  • 3
    • 0023936653 scopus 로고
    • Complications of needle localization of foreign bodies and nonpalpable breast lesions
    • Bronstein AD, Kilcoyne RF, Moe RE. Complications of needle localization of foreign bodies and nonpalpable breast lesions. Arch Surg 1988;123: 775-779
    • (1988) Arch Surg , vol.123 , pp. 775-779
    • Bronstein, A.D.1    Kilcoyne, R.F.2    Moe, R.E.3
  • 4
    • 0018583182 scopus 로고
    • Percutaneous localization of breast lesions: Experience with the Frank breast biopsy guide
    • Homer MJ. Percutaneous localization of breast lesions: experience with the Frank breast biopsy guide. J Can Assoc Radiol 1979;30:238-241
    • (1979) J Can Assoc Radiol , vol.30 , pp. 238-241
    • Homer, M.J.1
  • 5
    • 0023836425 scopus 로고
    • Migration of breast biopsy localization wire
    • Davis PS, Wechsler RJ, Feig SA, March DE. Migration of breast biopsy localization wire. AJR 1988;150:787-788
    • (1988) AJR , vol.150 , pp. 787-788
    • Davis, P.S.1    Wechsler, R.J.2    Feig, S.A.3    March, D.E.4
  • 6
    • 0019377771 scopus 로고
    • Transgression of localizing wire into the pleural cavity prior to mammography
    • Bristol JB, Jones PA. Transgression of localizing wire into the pleural cavity prior to mammography. Br J Radiol 1981;54:139-140
    • (1981) Br J Radiol , vol.54 , pp. 139-140
    • Bristol, J.B.1    Jones, P.A.2
  • 7
    • 0025732907 scopus 로고
    • Migration of localizing wires used in guided biopsy of the breast
    • Owen AW, Kumar EN. Migration of localizing wires used in guided biopsy of the breast. Clin Radiol 1991;43:251
    • (1991) Clin Radiol , vol.43 , pp. 251
    • Owen, A.W.1    Kumar, E.N.2
  • 8
    • 0020955166 scopus 로고
    • Transaction of the localization hooked wire during breast biopsy
    • Homer MJ. Transaction of the localization hooked wire during breast biopsy. AJR 1983;141: 929-930
    • (1983) AJR , vol.141 , pp. 929-930
    • Homer, M.J.1
  • 10
    • 0024077280 scopus 로고
    • Migration of the localization wire
    • Homer MJ. Migration of the localization wire (letter). AJR 1988;151:615
    • (1988) AJR , vol.151 , pp. 615
    • Homer, M.J.1
  • 11
    • 85035176934 scopus 로고    scopus 로고
    • Wright v Carter, 604 NE2d 1236 (Ind. App 1992)
    • Wright v Carter, 604 NE2d 1236 (Ind. App 1992)
  • 12
    • 0023754062 scopus 로고
    • Localization of nonpalpable breast lesions with the curved-end, retractable wire: Leaving the needle in vivo
    • Homer MJ. Localization of nonpalpable breast lesions with the curved-end, retractable wire: leaving the needle in vivo. AJR 1988;151:919-920
    • (1988) AJR , vol.151 , pp. 919-920
    • Homer, M.J.1