메뉴 건너뛰기




Volumn 26, Issue 4, 1996, Pages 259-264

Fast spin-echo MR imaging of the pediatric brain

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ARTICLE; ARTIFACT; BRAIN BLOOD FLOW; BRAIN DISEASE; BRAIN ISCHEMIA; CHILD; DEGENERATIVE DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; ENCEPHALITIS; FEMALE; GROWTH RETARDATION; HUMAN; INFANT; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MYELINATION; NEWBORN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; TIME;

EID: 0029892015     PISSN: 03010449     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF01372107     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 0022872540 scopus 로고
    • RARA imaging: A fast imaging method for clinical MR
    • Hennig J, Naureth A, Friedburg H (1986) RARA imaging: a fast imaging method for clinical MR. Magn Reson Med 3: 823-833
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Naureth, A.2    Friedburg, H.3
  • 3
    • 0027103743 scopus 로고
    • Practical choices of fast spin echo pulse sequence parameters: Clinically useful proton density and T2-weighted contrasts
    • Tien RD, Felsberg GJ, MacFall J (1992) Practical choices of fast spin echo pulse sequence parameters: clinically useful proton density and T2-weighted contrasts. Neuroradiology 35: 38-41
    • (1992) Neuroradiology , vol.35 , pp. 38-41
    • Tien, R.D.1    Felsberg, G.J.2    MacFall, J.3
  • 4
    • 0026601273 scopus 로고
    • Signal-to-noise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging
    • Constable RT, Smith RC, Gore JC (1992) Signal-to-noise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging. J Comput Assist Tomogr 16: 41-47
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 41-47
    • Constable, R.T.1    Smith, R.C.2    Gore, J.C.3
  • 6
    • 0026460046 scopus 로고
    • Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences
    • Norbash AM, Glover GH, Enzmann DR (1992) Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences. Radiology 185: 661-665
    • (1992) Radiology , vol.185 , pp. 661-665
    • Norbash, A.M.1    Glover, G.H.2    Enzmann, D.R.3
  • 10
    • 0028328569 scopus 로고
    • MR detection of white matter disease of the brain in patients with HIV infection: Fast spin-echo vs conventional spinecho pulse sequences
    • Olson EM, Healy JF, Wong WHM, Youmans DC, Hesselink JR (1994) MR detection of white matter disease of the brain in patients with HIV infection: fast spin-echo vs conventional spinecho pulse sequences. AJR 162: 1199-1204
    • (1994) AJR , vol.162 , pp. 1199-1204
    • Olson, E.M.1    Healy, J.F.2    Wong, W.H.M.3    Youmans, D.C.4    Hesselink, J.R.5
  • 12
    • 0028390559 scopus 로고
    • Comparison of T2-weighted spin-echo and fast spin-echo techniques in the evaluation of myelination
    • Prenger EC, Bcckctt WW, Kollias SS, Ball WS (1994) Comparison of T2-weighted spin-echo and fast spin-echo techniques in the evaluation of myelination. J Magn Reson Imaging 4: 179-184
    • (1994) J Magn Reson Imaging , vol.4 , pp. 179-184
    • Prenger, E.C.1    Bcckctt, W.W.2    Kollias, S.S.3    Ball, W.S.4
  • 15
    • 0025050629 scopus 로고
    • Contrast manipulation and artifact assessment of 2D and 3D RARE sequences
    • Mulkern RV, Wong STS, Winalski C, Jolesz FA (1990) Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. Magn Reson Imaging 8: 557-566
    • (1990) Magn Reson Imaging , vol.8 , pp. 557-566
    • Mulkern, R.V.1    Wong, S.T.S.2    Winalski, C.3    Jolesz, F.A.4
  • 16
    • 0027281022 scopus 로고
    • Turbo(Fast)-Spinecho bei 0,5 T: Einfluß der Echodistanz und Echozahl auf den Bildkontrast
    • Vahlensiek M, Seelos K, Gieseke J, Reiser M (1993) Turbo(Fast)-Spinecho bei 0,5 T: Einfluß der Echodistanz und Echozahl auf den Bildkontrast. Fortschr Rontgenstr 158: 260-264
    • (1993) Fortschr Rontgenstr , vol.158 , pp. 260-264
    • Vahlensiek, M.1    Seelos, K.2    Gieseke, J.3    Reiser, M.4
  • 18


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.