메뉴 건너뛰기




Volumn 199, Issue 3, 1996, Pages 855-860

Development of an MR simulator: Experimental verification of geometric distortion and clinical application

Author keywords

Magnetic resonance (MR), treatment planning; Treatment planning

Indexed keywords

ADULT; AGED; ARTICLE; BONE METASTASIS; BONE TUMOR; CLINICAL ARTICLE; FEMALE; GEOMETRY; HUMAN; IMAGE DISPLAY; MAGNETIC FIELD; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; RADIATION FIELD; RADIOTHERAPY; SIMULATOR; TREATMENT PLANNING;

EID: 0029889031     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.199.3.8638017     Document Type: Article
Times cited : (33)

References (20)
  • 1
    • 0021810043 scopus 로고
    • MR imaging in radiation therapy planning
    • Shuman WP, Griffin BR, Haynor DR, et al. MR imaging in radiation therapy planning. Radiology 1985; 156:143-147.
    • (1985) Radiology , vol.156 , pp. 143-147
    • Shuman, W.P.1    Griffin, B.R.2    Haynor, D.R.3
  • 2
    • 0026068688 scopus 로고
    • Imaging bone tumors in the 1990s
    • Murphy WA Jr. Imaging bone tumors in the 1990s. Cancer 1991; 67:1169-1176.
    • (1991) Cancer , vol.67 , pp. 1169-1176
    • Murphy Jr., W.A.1
  • 3
    • 0026531088 scopus 로고
    • Sagittal and coronal planes from MRI for treatment planning in tumors of brain, head and neck: MRI assisted simulation
    • Pötter R, Heil B, Schneider L, Lenzen H, Al-Dandashi C, Schnepper E. Sagittal and coronal planes from MRI for treatment planning in tumors of brain, head and neck: MRI assisted simulation. Radiother Oncol 1992; 23:127-130.
    • (1992) Radiother Oncol , vol.23 , pp. 127-130
    • Pötter, R.1    Heil, B.2    Schneider, L.3    Lenzen, H.4    Al-Dandashi, C.5    Schnepper, E.6
  • 4
    • 0023502553 scopus 로고
    • Integration of magnetic resonance imaging into radiation therapy treatment planning. I. Technical considerations
    • Fraass BA, McShan DL, Diaz RF, et al. Integration of magnetic resonance imaging into radiation therapy treatment planning. I. Technical considerations. Int J Radiat Oncol Biol Phys 1987; 13:1897-1908.
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , pp. 1897-1908
    • Fraass, B.A.1    McShan, D.L.2    Diaz, R.F.3
  • 5
    • 0028361944 scopus 로고
    • On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery
    • Michiels J, Bosmans H, Pelgrims P, et al. On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery. Magn Reson Imaging 1994; 12:749-765.
    • (1994) Magn Reson Imaging , vol.12 , pp. 749-765
    • Michiels, J.1    Bosmans, H.2    Pelgrims, P.3
  • 7
    • 0026557256 scopus 로고
    • MRI and MRA in treatment planning of subdiaphragmatic radiation therapy
    • Müller-Schimpfle M, Layer G, Köster A, et al. MRI and MRA in treatment planning of subdiaphragmatic radiation therapy. J Comput Assist Tomogr 1992; 16:110-119.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 110-119
    • Müller-Schimpfle, M.1    Layer, G.2    Köster, A.3
  • 8
    • 0023186402 scopus 로고
    • Correction of spatial distortion in MR imaging: A prerequisite for accurate stereotaxy
    • Schad L, Lott S, Schmitt F, Sturm V, Lorenz WJ. Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. J Comput Assist Tomogr 1987; 11:499-505.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 499-505
    • Schad, L.1    Lott, S.2    Schmitt, F.3    Sturm, V.4    Lorenz, W.J.5
  • 9
    • 0026250576 scopus 로고
    • Quantitation of structural distortion of the cervical neural foramina in gradient-echo MR imaging
    • Tien RD, Buxton RB, Schwaighofer BW, Chu PK. Quantitation of structural distortion of the cervical neural foramina in gradient-echo MR imaging. JMRI 1991; 1:683-687.
    • (1991) JMRI , vol.1 , pp. 683-687
    • Tien, R.D.1    Buxton, R.B.2    Schwaighofer, B.W.3    Chu, P.K.4
  • 10
    • 0026652757 scopus 로고
    • A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination
    • Kondziolka D, Dempsey PK, Lunsford LD, et al. A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Neurosurgery 1992; 30:402-407.
    • (1992) Neurosurgery , vol.30 , pp. 402-407
    • Kondziolka, D.1    Dempsey, P.K.2    Lunsford, L.D.3
  • 11
    • 0025344011 scopus 로고
    • CT simulator: A new 3-D planning and simulating system for radiotherapy. I. Description of system
    • Nishidai T, Nagata Y, Takahashi M, et al. CT simulator: a new 3-D planning and simulating system for radiotherapy. I. Description of system. Int J Radiat Oncol Biol Phys 1990; 18:499-504.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 499-504
    • Nishidai, T.1    Nagata, Y.2    Takahashi, M.3
  • 12
    • 0025275666 scopus 로고
    • CT simulator: A new 3-D planning and simulating system for radiotherapy. II. Clinical application
    • Nagata Y, Nishidai T, Abe M, et al. CT simulator: a new 3-D planning and simulating system for radiotherapy. II. Clinical application. Int J Radiat Oncol Biol Phys 1990; 18:505-513.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 505-513
    • Nagata, Y.1    Nishidai, T.2    Abe, M.3
  • 13
    • 0002128935 scopus 로고
    • Development of the CT simulator and evaluation of its clinical efficacy
    • Nagata Y, Okajima K, Murata R, et al. Development of the CT simulator and evaluation of its clinical efficacy. J Jpn Soc Ther Radiol Oncol 1995; 7:65-75.
    • (1995) J Jpn Soc Ther Radiol Oncol , vol.7 , pp. 65-75
    • Nagata, Y.1    Okajima, K.2    Murata, R.3
  • 14
    • 0026487072 scopus 로고
    • The clinical utility of magnetic resonance imaging in 3-dimensional treatment planning of brain neoplasms
    • Thornton AF Jr, Sandler HM, Ten Haken RK, et al. The clinical utility of magnetic resonance imaging in 3-dimensional treatment planning of brain neoplasms. Int J Radiat Oncol Biol Phys 1992; 24:767-775.
    • (1992) Int J Radiat Oncol Biol Phys , vol.24 , pp. 767-775
    • Thornton Jr., A.F.1    Sandler, H.M.2    Ten Haken, R.K.3
  • 15
    • 0028213621 scopus 로고
    • Image fusion for stereotactic radiotherapy and radiosurgery treatment planning
    • Kooy HM, van Herk M, Barnes PD, et al. Image fusion for stereotactic radiotherapy and radiosurgery treatment planning. Int J Radiat Oncol Biol Phys 1994; 28:1229-1234.
    • (1994) Int J Radiat Oncol Biol Phys , vol.28 , pp. 1229-1234
    • Kooy, H.M.1    Van Herk, M.2    Barnes, P.D.3
  • 16
    • 0025760409 scopus 로고
    • Image correlation of MRI and CT in treatment planning for radiosurgery of intracranial vascular malformations
    • Phillips MH, Kessler M, Chuang FYS, et al. Image correlation of MRI and CT in treatment planning for radiosurgery of intracranial vascular malformations. Int J Radiat Oncol Biol Phys 1991; 20:881-889.
    • (1991) Int J Radiat Oncol Biol Phys , vol.20 , pp. 881-889
    • Phillips, M.H.1    Kessler, M.2    Chuang, F.Y.S.3
  • 18
    • 0029053859 scopus 로고
    • MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy
    • Sumanaweera TS, Glover GH, Hemler PF, et al. MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy. Magn Reson Imaging 1995; 34:106-113.
    • (1995) Magn Reson Imaging , vol.34 , pp. 106-113
    • Sumanaweera, T.S.1    Glover, G.H.2    Hemler, P.F.3
  • 19
    • 0026472070 scopus 로고
    • A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors
    • Ten Haken RK, Thornton AF Jr, Sandler HM, et al. A quantitative assessment of the addition of MRI to CT-based, 3-D treatment planning of brain tumors. Radiother Oncol 1992; 25:121-133.
    • (1992) Radiother Oncol , vol.25 , pp. 121-133
    • Ten Haken, R.K.1    Thornton Jr., A.F.2    Sandler, H.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.