메뉴 건너뛰기




Volumn 33, Issue 5, 1996, Pages 521-529

Evaluation of the clinical usefulness of super dynamic99mTc-HM-PAO SPECT in ischemic cerebrovascular disease - detection of hypo- and hyperperfusion area

Author keywords

99mTc d; Dynamic SPECT; Hyperfixation; l hexamethyl propyleneamine oxime (99mTc HM PAO); Luxury perfusion; Single photon emission computed tomography (SPECT)

Indexed keywords

HEXAMETHYLPROPYLENE AMINE OXIME TECHNETIUM TC 99M;

EID: 0029888227     PISSN: 00227854     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (20)
  • 1
    • 0026604691 scopus 로고
    • Kinetic behavior of Tc-99m-HMPAO in the human brain and quantification of cerebral blood flow using dynamic
    • Murase K, Tanada S, Fujita H, Sakaki S, Hamamoto K: Kinetic behavior of Tc-99m-HMPAO in the human brain and quantification of cerebral blood flow using dynamic SPECT. J Nucl Med 33:135-143, 1992
    • (1992) SPECT. J Nucl Med , vol.33 , pp. 135-143
    • Murase, K.1    Tanada, S.2    Fujita, H.3    Sakaki, S.4    Hamamoto, K.5
  • 3
    • 0027533383 scopus 로고
    • Hyperfixation of HMPAO in subacute ischemic stroke leading to spuriously high estimates of cerebral blood flow by SPECT
    • Sperling B, Lassen NA: Hyperfixation of HMPAO in subacute ischemic stroke leading to spuriously high estimates of cerebral blood flow by SPECT. Stroke 24: 193-194, 1993
    • (1993) Stroke , vol.24 , pp. 193-194
    • Sperling, B.1    Lassen, N.A.2
  • 4
    • 28144435084 scopus 로고    scopus 로고
    • Japanese source
  • 5
    • 28144437197 scopus 로고    scopus 로고
    • Japanese source
  • 6
    • 28144446648 scopus 로고    scopus 로고
    • Japanese source
  • 7
    • 28144456456 scopus 로고
    • Radioisotopes 37: 35-38, 1988
    • (1988) Radioisotopes , vol.37 , pp. 35-38
  • 8
    • 28144455135 scopus 로고
    • Rapid sequential SPECT study in cerebral vascular diseases using a ring detector SPECT (HEADTOME-II)
    • (Abstract)
    • Yamaoka N, Nakagawara J, Yamagishi H, Satoh K: Rapid sequential SPECT study in cerebral vascular diseases using a ring detector SPECT (HEADTOME-II). J Nucl Med 29: 880,1988 (Abstract)
    • (1988) J Nucl Med , vol.29 , pp. 880
    • Yamaoka, N.1    Nakagawara, J.2    Yamagishi, H.3    Satoh, K.4
  • 9
    • 0018411982 scopus 로고
    • Two methods for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations
    • Kanno I, Lassen NA: Two methods for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations. J Comput Assist Tomogr 3: 71-76, 1979
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 71-76
    • Kanno, I.1    Lassen, N.A.2
  • 10
    • 28144449985 scopus 로고    scopus 로고
    • Japanese source
  • 11
    • 0026349024 scopus 로고
    • Minor changes in regional cerebral blood flow revealed by the early distribution of 1-123 IMP in brain
    • Takeshita G, Toyama H, Nakane K, Maeda H, Katada K, Takeuchi A, et al: Minor changes in regional cerebral blood flow revealed by the early distribution of 1-123 IMP in brain. Radiation Medicine 9: 196-201,1991
    • (1991) Radiation Medicine , vol.9 , pp. 196-201
    • Takeshita, G.1    Toyama, H.2    Nakane, K.3    Maeda, H.4    Katada, K.5    Takeuchi, A.6
  • 12
  • 13
    • 0025248826 scopus 로고
    • Role of fast data acquisition method with Tc-99m HMPAO brain SPECT in patients with acute stroke
    • Oshima M, Tadokoro M, Makino N, Sakuma S: Role of fast data acquisition method with Tc-99m HMPAO brain SPECT in patients with acute stroke. Clin Nucl Med 15: 172-174, 1990
    • (1990) Clin Nucl Med , vol.15 , pp. 172-174
    • Oshima, M.1    Tadokoro, M.2    Makino, N.3    Sakuma, S.4
  • 14
    • 0026505856 scopus 로고
    • Comparison of Tc-99m HMPAO fast SPECT with Tc-99m HMPAO conventional SPECT in patients with acute stroke
    • Oshima M, Tadokoro M, Sakuma S: Comparison of Tc-99m HMPAO fast SPECT with Tc-99m HMPAO conventional SPECT in patients with acute stroke. Clin Nucl Med 17: 18-22, 1992
    • (1992) Clin Nucl Med , vol.17 , pp. 18-22
    • Oshima, M.1    Tadokoro, M.2    Sakuma, S.3
  • 15
    • 0024361929 scopus 로고
    • Filling out phenomenon with Tc-99m HM-PAO brain SPECT at the site of mild cerebral ischemia
    • Hayashida K, Nishimura T, Imakita S, Uehara T: Filling out phenomenon with Tc-99m HM-PAO brain SPECT at the site of mild cerebral ischemia. J Nucl Med 30: 591-598, 1989
    • (1989) J Nucl Med , vol.30 , pp. 591-598
    • Hayashida, K.1    Nishimura, T.2    Imakita, S.3    Uehara, T.4
  • 16
    • 0028121095 scopus 로고
    • 99mTc-bicisate (BCD, Neurolite) measured by SPECT on same day
    • 99mTc-bicisate (BCD, Neurolite) measured by SPECT on same day. J Cereb Blood Flow Metab 14 (Suppl 1): S44-S48, 1994
    • (1994) J Cereb Blood Flow Metab , vol.14 , Issue.SUPPL. 1
    • Lassen, N.A.1    Sperling, B.2
  • 17
    • 0027300761 scopus 로고
    • Unreliability of rCBF-SPECT in subacute ischemic stroke
    • (Letter)
    • Limburg M, van Royen EA: Unreliability of rCBF-SPECT in subacute ischemic stroke. Stroke 24: 1099-1100, 1993 (Letter)
    • (1993) Stroke , vol.24 , pp. 1099-1100
    • Limburg, M.1    Van Royen, E.A.2
  • 18
    • 0014022317 scopus 로고
    • The luxury-perfusion syndrome and its possible relation to acute metabolic acidosis localised within the brain
    • Lassen NA: The luxury-perfusion syndrome and its possible relation to acute metabolic acidosis localised within the brain. Lancet ii: 1113-1115, 1966
    • (1966) Lancet , vol.2 , pp. 1113-1115
    • Lassen, N.A.1
  • 20
    • 28144433847 scopus 로고    scopus 로고
    • Japanese source


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.