메뉴 건너뛰기




Volumn 10, Issue 1, 1996, Pages 75-81

Three-dimensional ultrasound imaging of the eye

Author keywords

Ultrasound, experimental; Ultrasound, ophthalmic

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL EXAMINATION; CLINICAL TRIAL; DIAGNOSTIC VALUE; ECHOGRAPHY; EYE; EYE MALFORMATION; HUMAN; IMAGING SYSTEM; INFORMATION PROCESSING; MALE; MICROCOMPUTER; RADIOLOGY; THREE DIMENSIONAL IMAGING; TRANSDUCER;

EID: 0029883745     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/eye.1996.11     Document Type: Article
Times cited : (42)

References (21)
  • 4
    • 0027328536 scopus 로고
    • The role of colour flow Doppler ultrasonography in the investigation of disease in the eye and orbit
    • Munk P, Downey D, Nicolle D, Vellet AD, Rankin R, Lin DT. The role of colour flow Doppler ultrasonography in the investigation of disease in the eye and orbit. Can J Ophthalmol 1993; 28:171-6.
    • (1993) Can J Ophthalmol , vol.28 , pp. 171-176
    • Munk, P.1    Downey, D.2    Nicolle, D.3    Vellet, A.D.4    Rankin, R.5    Lin, D.T.6
  • 5
    • 0027438364 scopus 로고
    • Orbital colour Doppler imaging
    • Aburn NS, Sergott RC. Orbital colour Doppler imaging. Eye 1993;7:639-47.
    • (1993) Eye , vol.7 , pp. 639-647
    • Aburn, N.S.1    Sergott, R.C.2
  • 6
    • 9044250679 scopus 로고
    • Relative strength and limitations of diagnostic imaging studies
    • Boston: Little, Brown, chap.3
    • Straub WH. Relative strength and limitations of diagnostic imaging studies. In: Manual of diagnostic imaging, 2nd ed. Boston: Little, Brown, 1989: chap.3.
    • (1989) Manual of Diagnostic Imaging, 2nd Ed.
    • Straub, W.H.1
  • 9
    • 0027490323 scopus 로고
    • Three-dimensional sonographic reconstruction: Techniques and diagnostic applications
    • Rankin RN, Fenster A, Downey DB, Munk PL, Levin MF, Vellet AD. Three-dimensional sonographic reconstruction: techniques and diagnostic applications. AJR 1993;161:695-702.
    • (1993) AJR , vol.161 , pp. 695-702
    • Rankin, R.N.1    Fenster, A.2    Downey, D.B.3    Munk, P.L.4    Levin, M.F.5    Vellet, A.D.6
  • 14
    • 0000287326 scopus 로고
    • Orbital lesion localisation by three dimensional ultrasonography
    • Baum G. Orbital lesion localisation by three dimensional ultrasonography. NY State J Med 1961;61:4149-57.
    • (1961) NY State J Med , vol.61 , pp. 4149-4157
    • Baum, G.1
  • 15
    • 0025849676 scopus 로고
    • Ultrasonographic, three-dimensional scanning for determination of intraocular tumour volume
    • Copenh
    • Jensen PK, Hansen MK. Ultrasonographic, three-dimensional scanning for determination of intraocular tumour volume. Acta Ophthalmol (Copenh) 1991;69:176-86.
    • (1991) Acta Ophthalmol , vol.69 , pp. 176-186
    • Jensen, P.K.1    Hansen, M.K.2
  • 19
    • 0026743432 scopus 로고
    • Sophisticated instrumentation and ophthalmic ultrasonography
    • Buschmann W. Sophisticated instrumentation and ophthalmic ultrasonography. Acta Ophthalmol Suppl 1992;204:18-21.
    • (1992) Acta Ophthalmol Suppl , vol.204 , pp. 18-21
    • Buschmann, W.1
  • 21
    • 0001668636 scopus 로고
    • The size and shape of malignant melanomas of the choroid and ciliary body in relation to prognosis and histologic characteristics
    • Flock M, Gerende JH, Zimmerman LE. The size and shape of malignant melanomas of the choroid and ciliary body in relation to prognosis and histologic characteristics. Trans Am Acad Ophthalmol Otolaryngol 1955;59:740.
    • (1955) Trans Am Acad Ophthalmol Otolaryngol , vol.59 , pp. 740
    • Flock, M.1    Gerende, J.H.2    Zimmerman, L.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.