메뉴 건너뛰기




Volumn 39, Issue 2, 1996, Pages 117-121

Replacement of hairpin and loop implants by optimised straight line sources

Author keywords

dwell position weight; hairpin loop implant; oral cavity; straight catheter

Indexed keywords

ARTICLE; BRACHYTHERAPY; CATHETER; HUMAN; MOUTH CARCINOMA; PRIORITY JOURNAL;

EID: 0029877290     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/0167-8140(96)01720-3     Document Type: Article
Times cited : (15)

References (5)
  • 1
    • 0012462316 scopus 로고
    • Geometry based optimisation for stepping source implants
    • Edmundson, R.T. Geometry based optimisation for stepping source implants. SELECTRON Brachyther. J. 5: 22-26, 1991.
    • (1991) SELECTRON Brachyther. J. , vol.5 , pp. 22-26
    • Edmundson, R.T.1
  • 2
    • 0343074045 scopus 로고
    • HDR and PDR brachytherapy with special reference to base of tongue cancer
    • Editors: R.F. Mould, J.J. Battermann, A.A. Martinez and B.L. Speiser
    • Levendag, P.C., Visser, A. G., Kolkman-Deurloo, I.K., Eijkenboom, W.M.H. and Meeuwis, C.A. HDR and PDR brachytherapy with special reference to base of tongue cancer. In: Brachytherapy from Radium to Optimisation, pp. 132-148. Editors: R.F. Mould, J.J. Battermann, A.A. Martinez and B.L. Speiser, 1994.
    • (1994) Brachytherapy from Radium to Optimisation , pp. 132-148
    • Levendag, P.C.1    Visser, A.G.2    Kolkman-Deurloo, I.K.3    Eijkenboom, W.M.H.4    Meeuwis, C.A.5
  • 3
    • 0028100292 scopus 로고
    • The study of tumoural, radiobiological and general health factors that influence results and complications in a series of 448 oral tongue carcinomas treated exclusively by irradiation
    • Pernot, M., Malisgard, L., Hoffstetter, S., Luprosi, E., Peiffert, D., Alleti, P., Kozminski, P. and Bey, P. The study of tumoural, radiobiological and general health factors that influence results and complications in a series of 448 oral tongue carcinomas treated exclusively by irradiation. Int. J. Radiat. Oncol., Biol. Phys. 29: 673-679, 1994.
    • (1994) Int. J. Radiat. Oncol., Biol. Phys. , vol.29 , pp. 673-679
    • Pernot, M.1    Malisgard, L.2    Hoffstetter, S.3    Luprosi, E.4    Peiffert, D.5    Alleti, P.6    Kozminski, P.7    Bey, P.8
  • 5
    • 0023883007 scopus 로고
    • A dose homogeneity index for evaluation: Ir-192 interstitial breast implants
    • Wu, A., Ulin, K. and Sternick, E.S. A dose homogeneity index for evaluation: Ir-192 interstitial breast implants. Med. Phys. 15: 104-107, 1988.
    • (1988) Med. Phys. , vol.15 , pp. 104-107
    • Wu, A.1    Ulin, K.2    Sternick, E.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.