메뉴 건너뛰기




Volumn 10, Issue 2, 1996, Pages 161-168

Ultrasound-guided neurosurgery: A feasibility study in the 3-30 MHz frequency range

Author keywords

Blood vessel; Brain tumour; Colour flow; High frequency; Intraoperative ultrasound; Surgical tool

Indexed keywords

ADULT; AGED; ARTICLE; B SCAN; BLOOD VESSEL; BRAIN TUMOR; CLINICAL ARTICLE; COLOR ULTRASOUND FLOWMETRY; FEASIBILITY STUDY; FORCEPS; HUMAN; PEROPERATIVE ECHOGRAPHY; PRIORITY JOURNAL; SURGICAL EQUIPMENT;

EID: 0029875043     PISSN: 02688697     EISSN: None     Source Type: Journal    
DOI: 10.1080/02688699650040313     Document Type: Article
Times cited : (30)

References (14)
  • 4
    • 0026787597 scopus 로고
    • Computer-assisted Neurosurgery: Simulation and Automation. Meeting of the American Society of Stereotactic and Functional Neurosurgery, Pittsburg, Pa. 1991
    • Zamorano L, Kadi AM, Dong A. Computer-assisted Neurosurgery: Simulation and Automation. Meeting of the American Society of Stereotactic and Functional Neurosurgery, Pittsburg, Pa. 1991, Stereotact Funct Neurosurg 1992;59:115-22.
    • (1992) Stereotact Funct Neurosurg , vol.59 , pp. 115-122
    • Zamorano, L.1    Kadi, A.M.2    Dong, A.3
  • 6
    • 0020534364 scopus 로고
    • Intraoperative neurosurgical ultrasound in the localization and characterization of intracranial masses
    • Rubin JM, Dohrmann GJ. Intraoperative neurosurgical ultrasound in the localization and characterization of intracranial masses. Radiology 1993;148:519-24.
    • (1993) Radiology , vol.148 , pp. 519-524
    • Rubin, J.M.1    Dohrmann, G.J.2
  • 7
    • 0025735991 scopus 로고
    • The value of intraoperative ultrasound in neurosurgery
    • Sutcliffe JC. The value of intraoperative ultrasound in neurosurgery. Br J Neurosurg 1991;5:169-78.
    • (1991) Br J Neurosurg , vol.5 , pp. 169-178
    • Sutcliffe, J.C.1
  • 8
    • 0025732248 scopus 로고
    • Intraoperative ultrasound-guided biopsy of intracranial lesions: Comparison with free hand biopsy
    • Sutcliffe JC, Battersby RDE. Intraoperative ultrasound-guided biopsy of intracranial lesions: comparison with free hand biopsy. Br J Neurosurg 1991;5:163-8.
    • (1991) Br J Neurosurg , vol.5 , pp. 163-168
    • Sutcliffe, J.C.1    Battersby, R.D.E.2
  • 9
    • 0027602202 scopus 로고
    • Evaluation of intraoperative ultrasound in neurosurgery
    • Kumar P, Sukthankar R, Damany BJ, Mishera J. Evaluation of intraoperative ultrasound in neurosurgery. Ann Acad Med 1993;22(Suppl):422-7.
    • (1993) Ann Acad Med , vol.22 , Issue.SUPPL. , pp. 422-427
    • Kumar, P.1    Sukthankar, R.2    Damany, B.J.3    Mishera, J.4
  • 10
    • 0026477905 scopus 로고
    • Ultrasound stereotaxic endoscopy in neurosurgery
    • Auer LM. Ultrasound stereotaxic endoscopy in neurosurgery. Acta Neurochirurg (Wien) 1992;Suppl.54:34-41.
    • (1992) Acta Neurochirurg (Wien) , Issue.54 SUPPL. , pp. 34-41
    • Auer, L.M.1
  • 12
    • 0023626954 scopus 로고
    • Endoscopic evacuation of an intracerebral and intraventricular haemorrhage
    • Ritschl E, Auer LM. Endoscopic evacuation of an intracerebral and intraventricular haemorrhage. Arch Dis Childh 1987;62:1163-81.
    • (1987) Arch Dis Childh , vol.62 , pp. 1163-1181
    • Ritschl, E.1    Auer, L.M.2
  • 13
    • 0026066451 scopus 로고
    • Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz
    • Lockwood GR, Ryan LK, Foster FS. Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz. Ultrasound Med Biol 1991;17:653-66.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 653-666
    • Lockwood, G.R.1    Ryan, L.K.2    Foster, F.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.