메뉴 건너뛰기




Volumn 248, Issue 2, 1996, Pages 135-141

Evaluation of nonisotopic binding assays for measuring vitamin B12 and folate in serum

Author keywords

Cloned enzyme donor immunoassay (CEDIA); Intermethod comparison; Ion capture (IC); Microparticle enzyme immunoassay (MEIA)

Indexed keywords

CYANOCOBALAMIN; FOLIC ACID;

EID: 0029867905     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/0009-8981(95)06248-3     Document Type: Article
Times cited : (14)

References (14)
  • 5
    • 0023821462 scopus 로고
    • The Abbott IMx™ automated benchtop immunochemistry analyzer system
    • Fiore M, Mitchell J, Doan T et al. The Abbott IMx™ automated benchtop immunochemistry analyzer system. Clin Chem 1988;34:1726-1732.
    • (1988) Clin Chem , vol.34 , pp. 1726-1732
    • Fiore, M.1    Mitchell, J.2    Doan, T.3
  • 6
    • 0039631991 scopus 로고
    • An automated digoxin assay on the IMx® system using soluble reagents and polyelectrolyte interaction as separation means
    • Pennington C, Cotter S, Fabian K et al. An automated digoxin assay on the IMx® system using soluble reagents and polyelectrolyte interaction as separation means [Abstract]. Clin Chem 1991;37:1046.
    • (1991) Clin Chem , vol.37 , pp. 1046
    • Pennington, C.1    Cotter, S.2    Fabian, K.3
  • 7
    • 0027366781 scopus 로고
    • Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: Novel approaches for separation and detection
    • Wilson DH, Bogacz JP, Forsythe CM et al. Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection. Clin Chem 1993;39:2090-2097.
    • (1993) Clin Chem , vol.39 , pp. 2090-2097
    • Wilson, D.H.1    Bogacz, J.P.2    Forsythe, C.M.3
  • 8
    • 0040818560 scopus 로고
    • Demonstration of third generation TSH assay performance on the Abbott IMx automated immunoassay analyzer
    • Quinn F, Mallas T, Turk P, Yu J. Demonstration of third generation TSH assay performance on the Abbott IMx automated immunoassay analyzer. Clin Chem 1993;39:1162.
    • (1993) Clin Chem , vol.39 , pp. 1162
    • Quinn, F.1    Mallas, T.2    Turk, P.3    Yu, J.4
  • 9
    • 0039039981 scopus 로고
    • Evaluation of the Abbott IMx estradiol assay
    • King EH, Stone JA. Evaluation of the Abbott IMx estradiol assay. Clin Chem 1993;39:1264.
    • (1993) Clin Chem , vol.39 , pp. 1264
    • King, E.H.1    Stone, J.A.2
  • 10
    • 0027171510 scopus 로고
    • Microparticle enzyme immunosssays for creatine kinase MB and ferritin on the Abbott AxSYM™ system
    • Simondson R, Sebek L, Moster J, Osikowics G, Brandt D. Microparticle enzyme immunosssays for creatine kinase MB and ferritin on the Abbott AxSYM™ system. Clin Chem 1993;39:1979.
    • (1993) Clin Chem , vol.39 , pp. 1979
    • Simondson, R.1    Sebek, L.2    Moster, J.3    Osikowics, G.4    Brandt, D.5
  • 11
    • 0040223941 scopus 로고
    • Microparticle enzyme immunoassay for the detection of antibody to hepatitis B e antigen
    • Robbins D, Batdorf S, Moore B. Microparticle enzyme immunoassay for the detection of antibody to hepatitis B e antigen. Clin Chem 1991;37:1049.
    • (1991) Clin Chem , vol.37 , pp. 1049
    • Robbins, D.1    Batdorf, S.2    Moore, B.3
  • 12
    • 85029984621 scopus 로고
    • An automated assay for total T3 on the IMx® system using soluble reagents and polyelectrolyte interaction as separation means
    • Abano DA, Mathews R, Keller C et al. An automated assay for total T3 on the IMx® system using soluble reagents and polyelectrolyte interaction as separation means. Clin Chem 1991;37:1048.
    • (1991) Clin Chem , vol.37 , pp. 1048
    • Abano, D.A.1    Mathews, R.2    Keller, C.3
  • 14
    • 0027535199 scopus 로고
    • 12 and folate assays
    • 12 and folate assays. Clin Chem 1993;39:700-701.
    • (1993) Clin Chem , vol.39 , pp. 700-701
    • Dworschack, R.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.