-
1
-
-
0028072726
-
Magnetic resonance microscopy of the rat carotid artery at 300 megahertz
-
L. Arnder, X. Zhou, G. P. Cofer, L. W. Hedlund, G. A. Johnson, Magnetic resonance microscopy of the rat carotid artery at 300 megahertz. Invest. Radiol. 29, 822-826 (1994).
-
(1994)
Invest. Radiol.
, vol.29
, pp. 822-826
-
-
Arnder, L.1
Zhou, X.2
Cofer, G.P.3
Hedlund, L.W.4
Johnson, G.A.5
-
2
-
-
0027569785
-
Characterization of atherosclerosis with a 1.5-T imaging system
-
G. E. Gold, J. M. Pauly, G. H. Glover, J. C. Moretto, A. Macovski, R. J. Herfkens, Characterization of atherosclerosis with a 1.5-T imaging system. J. Magn. Reson. Imaging 3, 399-407 (1993).
-
(1993)
J. Magn. Reson. Imaging
, vol.3
, pp. 399-407
-
-
Gold, G.E.1
Pauly, J.M.2
Glover, G.H.3
Moretto, J.C.4
Macovski, A.5
Herfkens, R.J.6
-
3
-
-
0028309801
-
Techniques for high-resolution MR imaging of atherosclerotic plaque
-
C. Yuan, J. S. Tsuruda, K. N. Beach, C. E. Hayes, M. S. Ferguson, C. E. Alpers, T. K. Foo, D. E. Strandness, Techniques for high-resolution MR imaging of atherosclerotic plaque. J. Magn. Reson. Imaging 4, 43-49 (1994).
-
(1994)
J. Magn. Reson. Imaging
, vol.4
, pp. 43-49
-
-
Yuan, C.1
Tsuruda, J.S.2
Beach, K.N.3
Hayes, C.E.4
Ferguson, M.S.5
Alpers, C.E.6
Foo, T.K.7
Strandness, D.E.8
-
4
-
-
9244247957
-
An in vitro method of measuring local arterial elasticity under pulsatile motion
-
K. C. Ghu, B. K. Rutt, An in vitro method of measuring local arterial elasticity under pulsatile motion, in "Proc., 11th SMRM Annual Meeting, 1992," p. 829.
-
Proc., 11th SMRM Annual Meeting, 1992
, pp. 829
-
-
Ghu, K.C.1
Rutt, B.K.2
-
6
-
-
0029278096
-
A technical problem in the calculation of laminar flow near irregular surfaces described by sampled geometric data
-
I. M. Katz, E. J. Shaughnessy, B. B Cress, A technical problem in the calculation of laminar flow near irregular surfaces described by sampled geometric data. J Biomech. 28, 461-464 (1995).
-
(1995)
J Biomech.
, vol.28
, pp. 461-464
-
-
Katz, I.M.1
Shaughnessy, E.J.2
Cress, B.B.3
-
7
-
-
0027359446
-
Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner
-
M. Drangova, D. W. Holdsworth, C. J. Boyd, P. J. Dunmore, M. R. Roach, A. Fenster, Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner. Physiol. Meas. 14, 277-290 (1993).
-
(1993)
Physiol. Meas.
, vol.14
, pp. 277-290
-
-
Drangova, M.1
Holdsworth, D.W.2
Boyd, C.J.3
Dunmore, P.J.4
Roach, M.R.5
Fenster, A.6
-
10
-
-
0003998388
-
-
CRC Press, Boca Raton, FL
-
R. C. Weast, Ed., "CRC Handbook of Chemistry and Physics," 68th Ed., pp. E-129, CRC Press, Boca Raton, FL, 1987.
-
(1987)
"CRC Handbook of Chemistry and Physics," 68th Ed.
-
-
Weast, R.C.1
-
11
-
-
9244250211
-
Freon Product Information G-1
-
E. I. DuPont Demours & Co., Wilmington, DE
-
Freon Product Information G-1, "Freon Fluorocarbons Properties and applications," E. I. DuPont Demours & Co., Wilmington, DE, 1985.
-
(1985)
Freon Fluorocarbons Properties and Applications
-
-
-
12
-
-
0028454484
-
Quadrupole gradient coil design and optimization: A printed circuit board approach
-
K. Chu, B. K. Rutt, Quadrupole gradient coil design and optimization: a printed circuit board approach. Magn. Reson. Med. 31, 652-659 (1994).
-
(1994)
Magn. Reson. Med.
, vol.31
, pp. 652-659
-
-
Chu, K.1
Rutt, B.K.2
-
13
-
-
0003435471
-
-
Brooks/Cole, Monterey, CA
-
J. L. Devore, "Probability and Statistics for Engineering and the Sciences," 2nd Ed., Brooks/Cole, Monterey, CA, 1987.
-
(1987)
"Probability and Statistics for Engineering and the Sciences," 2nd Ed.
-
-
Devore, J.L.1
-
14
-
-
0022444930
-
Proton relaxation times in arterial wall and atheromatous lesions in man
-
K. Soila, P. Nummi, T. Ekfors, M. Viamonte, M. Kormano, Proton relaxation times in arterial wall and atheromatous lesions in man. Invest. Radiol. 21, 411-415 (1986).
-
(1986)
Invest. Radiol.
, vol.21
, pp. 411-415
-
-
Soila, K.1
Nummi, P.2
Ekfors, T.3
Viamonte, M.4
Kormano, M.5
-
15
-
-
0022998188
-
The intrinsic signal-to-noise ratio in NMR imaging
-
W. A. Edelstein, G. H. Glover, C. J. Hardy, R. W. Redington, The intrinsic signal-to-noise ratio in NMR imaging. Magn. Reson. Med. 3, 604-618 (1986).
-
(1986)
Magn. Reson. Med.
, vol.3
, pp. 604-618
-
-
Edelstein, W.A.1
Glover, G.H.2
Hardy, C.J.3
Redington, R.W.4
-
16
-
-
33751268423
-
The reason for the shape of the distensibility curves of arteries
-
M. R. Roach, A. C. Burton, The reason for the shape of the distensibility curves of arteries. Can. J. Biochem. Physiol. 35, 681-690 (1957).
-
(1957)
Can. J. Biochem. Physiol.
, vol.35
, pp. 681-690
-
-
Roach, M.R.1
Burton, A.C.2
-
17
-
-
0020553885
-
Ultrastructural study of the effects of trichlorotrifluoroethane on the liver of hairless mice
-
J. E. McKnight, J. L. McGraw Jr., Ultrastructural study of the effects of trichlorotrifluoroethane on the liver of hairless mice. J. Submicrosc. Cytol. 15, 447-451 (1983)
-
(1983)
J. Submicrosc. Cytol.
, vol.15
, pp. 447-451
-
-
McKnight, J.E.1
McGraw Jr., J.L.2
-
18
-
-
9244233200
-
-
DuPont Canada, Inc., Mississauga, Ontario, May
-
F. A. Gartrell, "Freon TF Solvent: Material Safety Data Sheet," DuPont Canada, Inc., Mississauga, Ontario, May 1989.
-
(1989)
Freon TF Solvent: Material Safety Data Sheet
-
-
Gartrell, F.A.1
|