메뉴 건너뛰기




Volumn 7, Issue 2, 1996, Pages 210-218

Insights into the chromatography of proteins provided by mathematical modeling

Author keywords

[No Author keywords available]

Indexed keywords

ADSORPTION CHROMATOGRAPHY; ALGORITHM; COLUMN CHROMATOGRAPHY; MATHEMATICAL MODEL; PRIORITY JOURNAL; PROTEIN ANALYSIS; PROTEIN PROTEIN INTERACTION; REVIEW; THERMODYNAMICS;

EID: 0029864343     PISSN: 09581669     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-1669(96)80015-2     Document Type: Article
Times cited : (27)

References (51)
  • 1
    • 0343208085 scopus 로고
    • Computer implementation of simulalion models for non-linear, non-ideal chromatography. Part 1: Fundamental mathematical considerations
    • Smit JC, Smit HC, De Jager EM: Computer implementation of simulalion models for non-linear, non-ideal chromatography. Part 1: fundamental mathematical considerations. Anal Chim Acta 1980, 122:1-26.
    • (1980) Anal Chim Acta , vol.122 , pp. 1-26
    • Smit, J.C.1    Smit, H.C.2    De Jager, E.M.3
  • 2
    • 0000930816 scopus 로고
    • Analysis of peak profiles using statistical moments
    • Morton DW, Young CL: Analysis of peak profiles using statistical moments. J Chromatogr Sci 1995, 33:514-524.
    • (1995) J Chromatogr Sci , vol.33 , pp. 514-524
    • Morton, D.W.1    Young, C.L.2
  • 3
    • 10144229327 scopus 로고    scopus 로고
    • Fundamental questions in optimizing protein-chromatography using computer-aided process design
    • in press
    • Jungbauer A, Kaltenbrunner O: Fundamental questions in optimizing protein-chromatography using computer-aided process design. Biotechnol Bioeng 1996, in press.
    • (1996) Biotechnol Bioeng
    • Jungbauer, A.1    Kaltenbrunner, O.2
  • 4
    • 0000165584 scopus 로고
    • Interparticle and intraparticle mass transfer in chromatographic separation
    • Li Q, Grandmaison EW, Hsu CC, Talyor D, Goosen MFA: Interparticle and intraparticle mass transfer in chromatographic separation. Bioseparation 1995, 5:189-202. Intraparticle mass transfer is reviewed with respect to intraparticle convection in chromatography beads with gigapores. In addition, a comprehensive discussion is provided of the plate and rate theory is given.
    • (1995) Bioseparation , vol.5 , pp. 189-202
    • Li, Q.1    Grandmaison, E.W.2    Hsu, C.C.3    Talyor, D.4    Goosen, M.F.A.5
  • 5
    • 0028809057 scopus 로고
    • High-performance chromatography of amino acids, peptides and proteins: CXXXIX. Impact of operating parameters in large-scale chromatography of proteins
    • Mao QM, Prince IG, Hearn MTW: High-performance chromatography of amino acids, peptides and proteins: CXXXIX. Impact of operating parameters in large-scale chromatography of proteins. J Chromatogr A 1995, 691:273-283. The sectional model, a discontinuous flow model, is employed to study the processing rate, which is dependent on the flow rate, purity and column utilization. In this model, the chromatography column is assumed to be divided into a series of sections. Each section is then treated as a well mixed tank. The difference between the series of sections in the tank model and the sectional model is the flow. In the tank model, the flow is continuous, whereas in the sectional model, the flow is discontinuous. After a certain time, the liquid phase is transferred into the next section and is mixed again for a certain time period. Compared with the continuous and discontinuous flow models, the advantage of this model is that the time required for adsorption is taken into consideration. It is not obligatory for equilibrium to be attained in each section.
    • (1995) J Chromatogr A , vol.691 , pp. 273-283
    • Mao, Q.M.1    Prince, I.G.2    Hearn, M.T.W.3
  • 6
    • 0028279002 scopus 로고
    • Calculation of peak profiles in preparative chromatography of biomolecules
    • Jungbauer A, Hackl S, Yamamoto S: Calculation of peak profiles in preparative chromatography of biomolecules. J Chromatogr A 1994, 658:399-406.
    • (1994) J Chromatogr A , vol.658 , pp. 399-406
    • Jungbauer, A.1    Hackl, S.2    Yamamoto, S.3
  • 7
    • 26044444734 scopus 로고
    • A stochastic model of chromatography
    • Woodbury CP Jr: A stochastic model of chromatography. J Chromatogr Sci 1994, 32:339-348. Reports the stochastic model of chromatography as an extension of the early statistical theory of chromatography by Giddings and Eyring (Giddings JC, Eyring H: A molecular dynamic theory of chromatography. J Phys Chem 1955, 59:416-421). Each solute is considered to have a residence time that follows a random distribution. The model is developed for the linear situation.
    • (1994) J Chromatogr Sci , vol.32 , pp. 339-348
    • Woodbury C.P. Jr1
  • 8
    • 33947565881 scopus 로고
    • A molecular dynamic theory of chromatography
    • Woodbury CP Jr: A stochastic model of chromatography. J Chromatogr Sci 1994, 32:339-348. Reports the stochastic model of chromatography as an extension of the early statistical theory of chromatography by Giddings and Eyring (Giddings JC, Eyring H: A molecular dynamic theory of chromatography. J Phys Chem 1955, 59:416-421). Each solute is considered to have a residence time that follows a random distribution. The model is developed for the linear situation.
    • (1955) J Phys Chem , vol.59 , pp. 416-421
    • Giddings, J.C.1    Eyring, H.2
  • 9
    • 0028355515 scopus 로고
    • Modeling of preparative liquid chromatography
    • Golshan-Shirazi S, Guiochon G: Modeling of preparative liquid chromatography. J Chromatogr A 1994, 658:149-171. Provides a discussion of the ideal model and the equilibrium dispersive model of preparative chromatography for the single and multi-component situation. Guidelines are given for mathematical treatment of the different models and a general description of each model is provided. The paper does not consider proteins, however.
    • (1994) J Chromatogr A , vol.658 , pp. 149-171
    • Golshan-Shirazi, S.1    Guiochon, G.2
  • 10
    • 0028224509 scopus 로고
    • Rapid simulation of chromatographic band profiles on personal computers
    • Fellinger A, Guiochon G: Rapid simulation of chromatographic band profiles on personal computers. J Chromatogr A 1994, 658:511-515. These authors compare the computational time needed by different approaches for the simulation of the separation of a binary mixture.
    • (1994) J Chromatogr A , vol.658 , pp. 511-515
    • Fellinger, A.1    Guiochon, G.2
  • 11
    • 0001414766 scopus 로고
    • New equations for multicomponent adsorption kinetics
    • Talbot J, Jin X, Wang NHL: New equations for multicomponent adsorption kinetics. Langmuir 1994, 10:1663-1666.
    • (1994) Langmuir , vol.10 , pp. 1663-1666
    • Talbot, J.1    Jin, X.2    Wang, N.H.L.3
  • 12
    • 0028517538 scopus 로고
    • Materials of steric hindrance: Effects on adsorption kinetics and equlibria
    • Jin X, Talbot J, Wang NHL: Materials of steric hindrance: effects on adsorption kinetics and equlibria. Am Inst Chem Eng J 1994, 40:1685-1696. The RSA theory on a continuous surface is extended to proteins, leading to a RRA algorithm on a continuous surface. The model takes into consideration the accessible sites and predicts breakthrough curves at very high surface coverage. The asymmetry of a breakthrough curve can be described, which is a big advantage compared with other models such as the Thomas solution.
    • (1994) Am Inst Chem Eng J , vol.40 , pp. 1685-1696
    • Jin, X.1    Talbot, J.2    Wang, N.H.L.3
  • 14
    • 0028985274 scopus 로고
    • Further examination of a concerted cluster model of multivalent affinity - Heterogeneous adsorption of lactate-dehydrogenase to cibachrom-blue immobilized on cellulose
    • Dowd V, Yon RJ: Further examination of a concerted cluster model of multivalent affinity - heterogeneous adsorption of lactate-dehydrogenase to cibachrom-blue immobilized on cellulose. J Chromatogr A 1995, 693:15-21.
    • (1995) J Chromatogr A , vol.693 , pp. 15-21
    • Dowd, V.1    Yon, R.J.2
  • 15
    • 0029177141 scopus 로고
    • Chromatographic kinetic measurements of human serum-albumin adsorption on monoclonal-antibodies
    • Renard J, Vidalmadjar C, Sebille B, Lapresle C: Chromatographic kinetic measurements of human serum-albumin adsorption on monoclonal-antibodies. J Mol Recognit 1995, 8:85-89.
    • (1995) J Mol Recognit , vol.8 , pp. 85-89
    • Renard, J.1    Vidalmadjar, C.2    Sebille, B.3    Lapresle, C.4
  • 16
    • 0028589869 scopus 로고
    • Sorption kinetics and breakthrough curves for pepsin and chymosin using pepstatin A affinity membranes
    • Suen S, Etzel MR: Sorption kinetics and breakthrough curves for pepsin and chymosin using pepstatin A affinity membranes. J Chromatogr A 1994, 686:179-192.
    • (1994) J Chromatogr A , vol.686 , pp. 179-192
    • Suen, S.1    Etzel, M.R.2
  • 17
    • 0028351873 scopus 로고
    • Influence of lateral interactions on preparative protein chromatography
    • Li Y, Pinto NG: Influence of lateral interactions on preparative protein chromatography. J Chromatogr A 1994, 658:445-457.
    • (1994) J Chromatogr A , vol.658 , pp. 445-457
    • Li, Y.1    Pinto, N.G.2
  • 18
    • 0029077512 scopus 로고
    • Model for ion-exchange equilibria of macromolecules in preparative chromatography
    • Li Y, Pinto NG: Model for ion-exchange equilibria of macromolecules in preparative chromatography. J Chromatogr A 1995, 702:113-123. This paper demonstrates the significance of lateral interaction in ion-exchange chromatography. Unfortunately, the authors use a weak mathematical model for the simulation of peak profiles that neglects axial dispersion and extra column effect. Thus, the influence of lateral adsorption cannot be estimated out by superimposing the experimental and simulated peak profile. Despite its flaws, the description of adsorption isotherms by this model is of a very high predictive value.
    • (1995) J Chromatogr A , vol.702 , pp. 113-123
    • Li, Y.1    Pinto, N.G.2
  • 19
    • 0028605887 scopus 로고
    • Equilibrium and kinetic parameter of adsorption of α-chymotrypsinogen A onto hydrophobic porous adsorbent particles
    • Tongata A, Liapis AI, Siehr DJ: Equilibrium and kinetic parameter of adsorption of α-chymotrypsinogen A onto hydrophobic porous adsorbent particles. J Chromatogr A 1994, 686:21-29.
    • (1994) J Chromatogr A , vol.686 , pp. 21-29
    • Tongata, A.1    Liapis, A.I.2    Siehr, D.J.3
  • 20
    • 0028855549 scopus 로고
    • High-performance liquid chromatography of amino acids, peptides and proteins: Adsorption of horse heart cytochrome C onto a tentacle-type cation-exchanger
    • Xie J, Aguilar M, Hearn MTW: High-performance liquid chromatography of amino acids, peptides and proteins: adsorption of horse heart cytochrome C onto a tentacle-type cation-exchanger. J Chromatogr A 1995, 691:263-271.
    • (1995) J Chromatogr A , vol.691 , pp. 263-271
    • Xie, J.1    Aguilar, M.2    Hearn, M.T.W.3
  • 21
    • 0029031318 scopus 로고
    • Modeling non-linear elution of proteins in ion-exchange chromatography
    • Gallant SR, Kundu A, Cramer SM: Modeling non-linear elution of proteins in ion-exchange chromatography. J Chromatogr A 1995, 702:125-143. The SMA model is used for the prediction of peak profiles. The model does not allow an analytical solution of the adsorption isotherm; therefore, an implicit solution is employed. A shielding factor, which is a unique property of a protein interacting with a particular ion-exchanger at certain conditions, compensates for the influence of salt shielding.
    • (1995) J Chromatogr A , vol.702 , pp. 125-143
    • Gallant, S.R.1    Kundu, A.2    Cramer, S.M.3
  • 22
    • 0028966255 scopus 로고
    • Stoichiometric mass action model, explicit isotherm for mono-, di-, tri-, and tetrameric ions
    • Patrickios CS, Patrickios ES: Stoichiometric mass action model, explicit isotherm for mono-, di-, tri-, and tetrameric ions. J Chromatogr A 1995, 694:480-485. The explicit expression of the isotherm is shown to be possible for exact numbers of interaction sites. The same algorithm is not applicable when the number of interaction sites is very high, which is the case for proteins.
    • (1995) J Chromatogr A , vol.694 , pp. 480-485
    • Patrickios, C.S.1    Patrickios, E.S.2
  • 23
    • 0028923957 scopus 로고
    • Investigation of displacer equilibrium properties and mobile phase operating conditions in ion-exchange displacement chromatography
    • Brooks CA, Cramer SM: Investigation of displacer equilibrium properties and mobile phase operating conditions in ion-exchange displacement chromatography. J Chromatogr A 1995, 693:187-196.
    • (1995) J Chromatogr A , vol.693 , pp. 187-196
    • Brooks, C.A.1    Cramer, S.M.2
  • 24
    • 0029636796 scopus 로고
    • Optimization of step gradient separations: Considerations of nonlinear adsoption
    • Gallant SR, Kundu A, Cramer SM: Optimization of step gradient separations: considerations of nonlinear adsoption. Biotechnol Bioeng 1995, 47:355-372. The SMA model is used to optimize resolution in preparative ion-exchange chromatography. A finite difference grid is employed for numerical simulation of the peak profiles. This model takes into consideration the different axial dispersion properties for each protein, which may be of importance when proteins with different molecular masses are employed. The model also integrates the solubility of a protein, which is an important constraint in protein chromatography.
    • (1995) Biotechnol Bioeng , vol.47 , pp. 355-372
    • Gallant, S.R.1    Kundu, A.2    Cramer, S.M.3
  • 25
    • 0029240506 scopus 로고
    • Experimental and theoretical analysis of the chromatographic behaviour of protein purification fusions carrying charged tails
    • Le Borgne S, Graber M, Condoret JS: Experimental and theoretical analysis of the chromatographic behaviour of protein purification fusions carrying charged tails. Bioseparation 1995, 5:53-64. Polyglutamic acid tails are fused to β-galactosidase by recombinant DNA technology. Both the wild-type protein and the recombinant protein are purified by ion-exchange chromatography. Using the SDM formalism, the binding constants are calculated and found to be higher for the modified proteins.
    • (1995) Bioseparation , vol.5 , pp. 53-64
    • Le Borgne, S.1    Graber, M.2    Condoret, J.S.3
  • 26
    • 0029105258 scopus 로고
    • Numerical studies of multicomponent chromatography using pH gradients
    • Frey DD, Barnes A. Strong J: Numerical studies of multicomponent chromatography using pH gradients. Am Inst Chem Eng J 1995, 41:1171-1183. A model, which takes several buffer species into consideration, is developed for elution using pH gradients. The interaction of proteins with the ion-exchanger is thought to take place in a stoichiometric manner. The model provides good predictions of changes in pH. The non-linear isotherm situation is not incorporated.
    • (1995) Am Inst Chem Eng J , vol.41 , pp. 1171-1183
    • Frey, D.D.1    Barnes, A.2    Strong, J.3
  • 27
    • 20444465029 scopus 로고
    • Equilibrium isotherm for protein adsorption in a bisolute system
    • Hashim MA, Chu KH, Tsan PS: Equilibrium isotherm for protein adsorption in a bisolute system. Trans Inst Chem Engineers 1995, 73:22-26.
    • (1995) Trans Inst Chem Engineers , vol.73 , pp. 22-26
    • Hashim, M.A.1    Chu, K.H.2    Tsan, P.S.3
  • 28
    • 0028439233 scopus 로고
    • Adsorption of BSA on strongly basic chitosan - Equilibria
    • Yoshida H, Nishihara H, Kataoka T: Adsorption of BSA on strongly basic chitosan - equilibria. Biotechnol Bioeng 1994, 43:1087-1093.
    • (1994) Biotechnol Bioeng , vol.43 , pp. 1087-1093
    • Yoshida, H.1    Nishihara, H.2    Kataoka, T.3
  • 29
    • 0029938310 scopus 로고    scopus 로고
    • Adsorption isotherms in protein chromatography, combined influence of protein and salt concentration on adsorption isotherm
    • in press
    • Kaltenbrunner O, Jungbauer A: Adsorption isotherms in protein chromatography, combined influence of protein and salt concentration on adsorption isotherm. J Chromatogr A 1996, in press.
    • (1996) J Chromatogr A
    • Kaltenbrunner, O.1    Jungbauer, A.2
  • 30
    • 0028333721 scopus 로고
    • Advanced sorbents for preparative protein separation purposes
    • Boschetti E: Advanced sorbents for preparative protein separation purposes. J Chromatogr A 1994, 658:207-223.
    • (1994) J Chromatogr A , vol.658 , pp. 207-223
    • Boschetti, E.1
  • 31
    • 0029192316 scopus 로고
    • Determination of transport coefficients in microporous solids
    • Bülow M, Micke A: Determination of transport coefficients in microporous solids. Adsorption 1995, 1:29-39. A review describing macroscopic transient methods with respect to their applicability to the investigation of molecular transport in microporous adsorption systems. Although the focus is on the adsorption of low molecular weight substances, several processes are identical to the adsorption of proteins.
    • (1995) Adsorption , vol.1 , pp. 29-39
    • Bülow, M.1    Micke, A.2
  • 32
    • 0027596212 scopus 로고
    • Effect of intraparticle convection on the chromatography of biomacromolecules
    • Frey DO, Schweinheim E, Horváth C: Effect of intraparticle convection on the chromatography of biomacromolecules. Biotechnol Prog 1993, 9:273-284.
    • (1993) Biotechnol Prog , vol.9 , pp. 273-284
    • Frey, D.O.1    Schweinheim, E.2    Horváth, C.3
  • 33
    • 0028012153 scopus 로고
    • Perfusion chromatography - Effect of micropore diffusion on column performance in systems utilizing perfusive adsorbent particles with a bidisperse porous structure
    • Liapis AI, McCoy MA: Perfusion chromatography - effect of micropore diffusion on column performance in systems utilizing perfusive adsorbent particles with a bidisperse porous structure. J Chromatog A 1994, 660:85-96. This paper provides a perfusion chromatography model that considers a chromatography medium with a bidisperse pore structure. The model is based on the assumption that convection through the pore (perfusion) is unidirectional and diffusion is multi-directional, The contours of isoconcentration of adsorbed solute may provide a good measure for perfusion. As yet, the theoretical model has not been supported by experimental data, perhaps because the experimental determination of isoconcentration contours is not a simple task.
    • (1994) J Chromatog A , vol.660 , pp. 85-96
    • Liapis, A.I.1    McCoy, M.A.2
  • 34
    • 0028817386 scopus 로고
    • Bioseparation with permeable particles
    • Rodrigues AE, Loureiro JM, Chenou C, Rendueles de la Vega M: Bioseparation with permeable particles. J Chromatogr A 1995, 664:233-240. These authors apply the theory of constant normalized breakthrough curves to media such as gel in a shell media (Q-HyperD; BioSepra Inc. Massachusetts, USA). They observe a weak dependence of the HETP equation on flow rate, which is a characteristic property of perfusion chromatography. In addition, they suggest perfusion also occurs in Q-HyperD media, although it is physically impossible because the bead does not possess through-pores. Under their experimental conditions, Q-HyperD excludes the model protein and behaves like a non-porous medium. This may be the explanation for the small change in the HETP equation with flow rate.
    • (1995) J Chromatogr A , vol.664 , pp. 233-240
    • Rodrigues, A.E.1    Loureiro, J.M.2    Chenou, C.3    De La Rendueles Vega, M.4
  • 35
    • 0029256855 scopus 로고
    • Linear driving force approximation for intraparticle diffusion and convection in permeable supports
    • Carta G: Linear driving force approximation for intraparticle diffusion and convection in permeable supports. Chem Eng Sci 1995, 50:887-889.
    • (1995) Chem Eng Sci , vol.50 , pp. 887-889
    • Carta, G.1
  • 36
    • 0030149495 scopus 로고    scopus 로고
    • Protein adsorption on carbon exchangers: Comparison of macroporous and gel composite media
    • in press
    • Weaver LE, Carta G: Protein adsorption on carbon exchangers: comparison of macroporous and gel composite media. Biotechnol Prog 1996, in press. Provides an explanation of the adsorption mechanisms of a gel in a shell medium.
    • (1996) Biotechnol Prog
    • Weaver, L.E.1    Carta, G.2
  • 37
    • 0029128176 scopus 로고
    • Perfusion chromatography: Performance of periodic counter-current column operation and its comparison with fixed-bed operation
    • Heeter GA, Liapis AI: Perfusion chromatography: performance of periodic counter-current column operation and its comparison with fixed-bed operation. J Chromatogr A 1995, 711:3-21.
    • (1995) J Chromatogr A , vol.711 , pp. 3-21
    • Heeter, G.A.1    Liapis, A.I.2
  • 38
    • 0027684670 scopus 로고
    • Intraparticle protein diffusion effect on gradient station chromatography
    • Luo RG, Hsu JT: Intraparticle protein diffusion effect on gradient station chromatography. Separ Technol 1993, 3:221-229.
    • (1993) Separ Technol , vol.3 , pp. 221-229
    • Luo, R.G.1    Hsu, J.T.2
  • 39
    • 0029065371 scopus 로고
    • Nuclear magnetic resonance and the design of chromatographic separations
    • Lightfoot EN, Athalye AM, Coffman JL, Roper DK, Root TW: Nuclear magnetic resonance and the design of chromatographic separations. J Chromatogr A 1995, 707:45-55. These authors employ nuclear magnetic resonance to measure axial dispersion in a chromatography column.
    • (1995) J Chromatogr A , vol.707 , pp. 45-55
    • Lightfoot, E.N.1    Athalye, A.M.2    Coffman, J.L.3    Roper, D.K.4    Root, T.W.5
  • 40
    • 0030131341 scopus 로고    scopus 로고
    • Comparison of pore and surface diffusion in multicomponent adsorption and liquid chromatography systems
    • in press
    • Ma Z, Whitley RD, Wang NHL: Comparison of pore and surface diffusion in multicomponent adsorption and liquid chromatography systems. Am Inst Chem Eng J 1996, in press, The influence of pore and surface diffusion on peak broadening and peak tailing is investigated.
    • (1996) Am Inst Chem Eng J
    • Ma, Z.1    Whitley, R.D.2    Wang, N.H.L.3
  • 41
    • 0028954324 scopus 로고
    • Chromatographic separation of continuous mixtures in distributed pores
    • McCoy B: Chromatographic separation of continuous mixtures in distributed pores. J Chromatogr A 1995, 697:533-540.
    • (1995) J Chromatogr A , vol.697 , pp. 533-540
    • McCoy, B.1
  • 42
    • 0029054755 scopus 로고
    • Numerical simulation of hydrodynamic dispersion in a random manner
    • Martys NS: Numerical simulation of hydrodynamic dispersion in a random manner. J Chromatogr A 1995, 707:35-43.
    • (1995) J Chromatogr A , vol.707 , pp. 35-43
    • Martys, N.S.1
  • 43
    • 0028671781 scopus 로고
    • Parallel transport of BSA by surface and pore diffusion in strongly basic chitosan
    • Yoshida H, Yoshikawa M, Kataoka T: Parallel transport of BSA by surface and pore diffusion in strongly basic chitosan. Am Inst Chem Eng J 1994, 40:3034-2044.
    • (1994) Am Inst Chem Eng J , vol.40 , pp. 3034-12044
    • Yoshida, H.1    Yoshikawa, M.2    Kataoka, T.3
  • 44
    • 0029168391 scopus 로고
    • Diffusion and convective dispersion through arrays of spheres with surface adsorption, diffusion, and unequal solute partitioning
    • Edwards DA, Davis AM: Diffusion and convective dispersion through arrays of spheres with surface adsorption, diffusion, and unequal solute partitioning. Chem Eng Sci 1993, 50:1441-1454.
    • (1993) Chem Eng Sci , vol.50 , pp. 1441-1454
    • Edwards, D.A.1    Davis, A.M.2
  • 45
    • 0342773385 scopus 로고
    • Optimization of affinity and ion-exchange chromatographic process for the purification of proteins
    • in press
    • Mao QM, Heam MTG: Optimization of affinity and ion-exchange chromatographic process for the purification of proteins. Biotechol Bioeng 1906, in press. Presents a comparison of the sectional model and the non-porous particle adsorption model. The mathematical equations are derived very precisely.
    • (1906) Biotechol Bioeng
    • Mao, Q.M.1    Heam, M.T.G.2
  • 46
    • 0029035916 scopus 로고
    • Computer aided desk-top scale-up and optimization of chromatographic processes
    • Wiblin DJ, Simon DR Myhill GR: Computer aided desk-top scale-up and optimization of chromatographic processes. J Chromatogr A 1995, 702:81-87. Conventional methodology is used to set up the equations for the mass balance in order to calculate the peak profiles. A moving grid model is used for numerical simulation of the chromatographic process. The grid moves down the column in tandem with the protein. Therefore, computation is carried out only in the area of the column where the protein is present. Computation time is significantly reduced by this approach.
    • (1995) J Chromatogr A , vol.702 , pp. 81-87
    • Wiblin, D.J.1    Simon, D.R.2    Myhill, G.R.3
  • 47
    • 0029124401 scopus 로고
    • Optimal protein separation
    • Jennings LS, Teo KL, Wang FY, Yu O: Optimal protein separation. Comput Chem Eng 1995, 19:567-573. Optimization algorithms for analytical chromatography are employed for the preparative chromatography of proteins. Objective functions, such as the chromatography response function and chromatography optimization function, are defined and it is shown that each of the problems can be solved by standard min-max optimization problems.
    • (1995) Comput Chem Eng , vol.19 , pp. 567-573
    • Jennings, L.S.1    Teo, K.L.2    Wang, F.Y.3    Yu, O.4
  • 49
    • 84985720056 scopus 로고
    • Dynamische simulation der adsorption an polymeren adsorbentien
    • Title translation: Dynamic simulation of adsorption on polymeric sorbents
    • Sievers W, Muller G: Dynamische simulation der adsorption an polymeren adsorbentien. Chem Ing Tech 1995, 67:897-901. [Title translation: Dynamic simulation of adsorption on polymeric sorbents.] The computer program SIAD (simulation adsorptiver trennprozesse) allows a very efficient simulation of breakthrough curves through the use of a finite bath model. The computation time with this computer program is remarkably short.
    • (1995) Chem ing Tech , vol.67 , pp. 897-901
    • Sievers, W.1    Muller, G.2
  • 50
    • 0029000220 scopus 로고
    • Consolidation of the packing material in chromatographic columns under dynamic axial compression. I. Fundamental study
    • Guiochon G, Sarker M: Consolidation of the packing material in chromatographic columns under dynamic axial compression. I. Fundamental study. J Chromatogr A 1995, 704:247-268.
    • (1995) J Chromatogr A , vol.704 , pp. 247-268
    • Guiochon, G.1    Sarker, M.2
  • 51
    • 0028604602 scopus 로고
    • Effect of bed compression on high-performance liquid chromatography columns with gigaporous polymeric packings
    • Freitag R, Frey D, Horváth C: Effect of bed compression on high-performance liquid chromatography columns with gigaporous polymeric packings. J Chromatogr A 1995, 686:155-177. The behavior of chromatographic packings with gigapores is investigated. Below a certain packing pressure, the theoretical relationship between porosity, permeability and efficiency can be confirmed experimentally. The increased efficiency at higher packing pressure is explained by a higher intra-particle flow due to lower interstitial porosity.
    • (1995) J Chromatogr A , vol.686 , pp. 155-177
    • Freitag, R.1    Frey, D.2    Horváth, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.