메뉴 건너뛰기




Volumn 93, Issue 1, 1996, Pages 17-21

Die true-vista-bifokal-IOL: Aktuelle ergebnisse der europäischen multizentrischen studie

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIFOCAL LENS; CATARACT; CLINICAL TRIAL; FOLLOW UP; HUMAN; LENS IMPLANT; MAJOR CLINICAL STUDY; MULTICENTER STUDY; PHACOEMULSIFICATION; VISUAL ACUITY;

EID: 0029863294     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (17)
  • 2
    • 0026848188 scopus 로고
    • Abbildungsgute verschiedener Intraokularlinsentypen (mono-, bi- und multifokal) in Luft und in Wasser
    • Fries U, Ohrloff C, Schnaudigel OE (1992) Abbildungsgute verschiedener Intraokularlinsentypen (mono-, bi- und multifokal) in Luft und in Wasser. Ophthalmologe 89: 151-156
    • (1992) Ophthalmologe , vol.89 , pp. 151-156
    • Fries, U.1    Ohrloff, C.2    Schnaudigel, O.E.3
  • 3
    • 0025756949 scopus 로고
    • Visual and refractive results of multifocal intraocular lenses
    • Gimbel HV, Sanders DR, Raanan MG (1991) Visual and refractive results of multifocal intraocular lenses. Ophthalmology 98: 881-888
    • (1991) Ophthalmology , vol.98 , pp. 881-888
    • Gimbel, H.V.1    Sanders, D.R.2    Raanan, M.G.3
  • 4
    • 0028018374 scopus 로고
    • Mesopisches Sehen bei multi- und monofokaler Pseudophakie und phaken Kontrollaugen
    • Hessemer V, Frohloff H, Eisenmann D, Jacobi KW (1994) Mesopisches Sehen bei multi- und monofokaler Pseudophakie und phaken Kontrollaugen. Ophthalmologe 91: 465-468
    • (1994) Ophthalmologe , vol.91 , pp. 465-468
    • Hessemer, V.1    Frohloff, H.2    Eisenmann, D.3    Jacobi, K.W.4
  • 6
    • 0026605358 scopus 로고
    • Die True Vista Bifokal-IOL. Ergebnisse der Europäischen Multizentrischen Studie
    • Knorz MC (1992) Die True Vista Bifokal-IOL. Ergebnisse der Europäischen Multizentrischen Studie. Ophthalmologe 89: 157-161
    • (1992) Ophthalmologe , vol.89 , pp. 157-161
    • Knorz, M.C.1
  • 7
    • 0027320748 scopus 로고
    • Results of a European multicenter study of the true vista bifocal introcular lens
    • Knorz MC (1993) Results of a European multicenter study of the true vista bifocal introcular lens. J Cataract Refract Surg 19: 626-634
    • (1993) J Cataract Refract Surg , vol.19 , pp. 626-634
    • Knorz, M.C.1
  • 8
    • 0027548386 scopus 로고
    • Vision with bifocal introacular lenses
    • Knorz MC (1993) Vision with bifocal introacular lenses. German J Ophthalmol 2: 32-41
    • (1993) German J Ophthalmol , vol.2 , pp. 32-41
    • Knorz, M.C.1
  • 9
    • 0028437593 scopus 로고
    • A theoretical model to predict contrast sensitivity with bifocal intraocular lenses
    • Knorz MC (1994) A theoretical model to predict contrast sensitivity with bifocal intraocular lenses. German J Ophthalmol 3: 189-194
    • (1994) German J Ophthalmol , vol.3 , pp. 189-194
    • Knorz, M.C.1
  • 10
    • 3142552051 scopus 로고
    • Möglichkeiten und Grenzen bifokaler Intraokularlinsen
    • Knorz MC (1994) Möglichkeiten und Grenzen bifokaler Intraokularlinsen. Aktuelle Augenheilkd 19: 1-9
    • (1994) Aktuelle Augenheilkd , vol.19 , pp. 1-9
    • Knorz, M.C.1
  • 13
    • 0028006413 scopus 로고
    • Effect of pupil size and astigmatism on contrast acuity with monofocal and bifocal intraocular lenses
    • Knorz MC, Koch DD, Martinez-Franco C, Lorger C V (1994) Effect of pupil size and astigmatism on contrast acuity with monofocal and bifocal intraocular lenses. J Cataract Refract Surg 20: 26-33
    • (1994) J Cataract Refract Surg , vol.20 , pp. 26-33
    • Knorz, M.C.1    Koch, D.D.2    Martinez-Franco, C.3    Lorger, C.V.4
  • 14
    • 0027164555 scopus 로고
    • Indikationen und Kontraindikationen für die Implantation bifokaler Intraokularlinsen
    • Knorz MC, Liesenhoff H (1993) Indikationen und Kontraindikationen für die Implantation bifokaler Intraokularlinsen. Klin Monatsbl Augenheilkd 202: 500-506
    • (1993) Klin Monatsbl Augenheilkd , vol.202 , pp. 500-506
    • Knorz, M.C.1    Liesenhoff, H.2
  • 16
    • 0025798195 scopus 로고
    • Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes
    • Olsen T, Thim K, Corydon L (1991) Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg 17: 187-193
    • (1991) J Cataract Refract Surg , vol.17 , pp. 187-193
    • Olsen, T.1    Thim, K.2    Corydon, L.3
  • 17
    • 0024469731 scopus 로고
    • Photographic simulation of image quality through bifocal intraocular lenses
    • Zisser HC, Guyton DL (1989) Photographic simulation of image quality through bifocal intraocular lenses. Am J Ophthalmol 108: 324-326
    • (1989) Am J Ophthalmol , vol.108 , pp. 324-326
    • Zisser, H.C.1    Guyton, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.