메뉴 건너뛰기




Volumn 131, Issue 2, 1996, Pages 243-246

Secondary X-ray fluorescence for in vivo transdermal absorption measurements

Author keywords

5 Chloro 7 iodo 8 hydroxyquinoline; In vivo percutaneous absorption; Noninvasive; Topical delivery

Indexed keywords

AMERICIUM 241; CLIOQUINOL; IODINE; RADIOACTIVE MATERIAL; SAMARIUM;

EID: 0029863084     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/0378-5173(95)04345-4     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0015304332 scopus 로고
    • Skin permeability in vivo: Comparison in rat, rabbit, pig and man
    • Bartek, M.J., Labudde, J.A. and Maibach, H.I., Skin permeability in vivo: comparison in rat, rabbit, pig and man. J. Invest. Dermatol., 58 (1972) 114-123.
    • (1972) J. Invest. Dermatol. , vol.58 , pp. 114-123
    • Bartek, M.J.1    Labudde, J.A.2    Maibach, H.I.3
  • 2
    • 0022545493 scopus 로고
    • Regional variation in percutaneous absorption in man: Measurement by the skin stripping method
    • Rougier, A., Dupuis, D., Lotte, C., Rouget, R., Webster, R.C. and Maibach, H.I., Regional variation in percutaneous absorption in man: measurement by the skin stripping method. Arch. Dermatol. Res., 278 (1986) 465-469.
    • (1986) Arch. Dermatol. Res. , vol.278 , pp. 465-469
    • Rougier, A.1    Dupuis, D.2    Lotte, C.3    Rouget, R.4    Webster, R.C.5    Maibach, H.I.6
  • 3
    • 0027494949 scopus 로고
    • Validation of reflectance infrared spectroscopy as a quantitative method to measure percutaneous penetration in vivo
    • Higo, N.H., Naik, A., Bommannan, D.B., Potts, R.O. and Guy, R.H., Validation of reflectance infrared spectroscopy as a quantitative method to measure percutaneous penetration in vivo. Pharmacol. Res., 10 (1993) 1500-1506.
    • (1993) Pharmacol. Res. , vol.10 , pp. 1500-1506
    • Higo, N.H.1    Naik, A.2    Bommannan, D.B.3    Potts, R.O.4    Guy, R.H.5
  • 4
    • 0026471574 scopus 로고
    • Noninvasive in vivo percutaneous absorption measurements using X-ray fluorescence
    • Robertson, J.D., Ferguson, E., Jay, M. and Stalker, D.J., Noninvasive in vivo percutaneous absorption measurements using X-ray fluorescence. Pharmacol. Res., 9 (1992) 1410-1414.
    • (1992) Pharmacol. Res. , vol.9 , pp. 1410-1414
    • Robertson, J.D.1    Ferguson, E.2    Jay, M.3    Stalker, D.J.4
  • 5
    • 4243604061 scopus 로고
    • Noninvasive method for evaluating percutaneous absorption enhancers in vivo
    • MacLean, D.S., Robertson, J.D., Jay, M. and Stalker, D.J., Noninvasive method for evaluating percutaneous absorption enhancers in vivo. Pharmacol. Res., 9 (1992) S-195.
    • (1992) Pharmacol. Res. , vol.9
    • MacLean, D.S.1    Robertson, J.D.2    Jay, M.3    Stalker, D.J.4
  • 6
    • 0029051451 scopus 로고
    • Noninvasive measurement of protein release from subcutaneous depo formulations in vivo using X-ray fluorescence
    • in press
    • MacLean, D.S., Robertson, J.D., Stalker, D.J. and Jay, M., Noninvasive measurement of protein release from subcutaneous depo formulations in vivo using X-ray fluorescence. J. Control. Release (1995) in press.
    • (1995) J. Control. Release
    • MacLean, D.S.1    Robertson, J.D.2    Stalker, D.J.3    Jay, M.4
  • 7
    • 0017365722 scopus 로고
    • Measurement of lead content of childen's teeth in situ by X-ray fluorescence
    • Bloch, P., Garanoglie, G., Mitchell, G. and Shapiro, I.M., Measurement of lead content of childen's teeth in situ by X-ray fluorescence. Phys. Med. Biol., 20 (1976) 56-62.
    • (1976) Phys. Med. Biol. , vol.20 , pp. 56-62
    • Bloch, P.1    Garanoglie, G.2    Mitchell, G.3    Shapiro, I.M.4
  • 8
    • 0015658076 scopus 로고
    • Application of X-ray emission spectrometry to the determination of mercury in biological samples
    • Walsh, P., Hamrick, P. and Underwood, N., Application of X-ray emission spectrometry to the determination of mercury in biological samples. Rev. Sci. Instrum., 44 (1973) 1019-1026.
    • (1973) Rev. Sci. Instrum. , vol.44 , pp. 1019-1026
    • Walsh, P.1    Hamrick, P.2    Underwood, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.