Holter recordings with continuous marker annotations: A new tool in pacemaker diagnostics

Author keywords

Holter recording; marker annotations; telemetry

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CLINICAL ARTICLE; COMPUTER PROGRAM; DEVICE; FEMALE; HOLTER MONITORING; HUMAN; MALE; PACEMAKER FAILURE; SENSOR; TACHYCARDIA; TELEMETRY;

EID: 0029859356     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03226.x     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0021061042 scopus 로고
    • Apparent failure to sense (undersensing) caused by oversensing: Diagnostic use of a noninvasively obtained intracardiac electrogram
    • Warnowicz MA, Goldschlager N. Apparent failure to sense (undersensing) caused by oversensing: Diagnostic use of a noninvasively obtained intracardiac electrogram. PACE 1983; 6:1341-1343.
    • (1983) PACE , vol.6 , pp. 1341-1343
    • Warnowicz, M.A.1    Goldschlager, N.2
  • 2
    • 0020067841 scopus 로고
    • Pacemaker inhibition by myopotentials detected by Holter monitoring
    • Jacobs LJ, Kerzner JS, Diamond MA, et al. Pacemaker inhibition by myopotentials detected by Holter monitoring. PACE 1982; 5:30-33.
    • (1982) PACE , vol.5 , pp. 30-33
    • Jacobs, L.J.1    Kerzner, J.S.2    Diamond, M.A.3
  • 3
    • 0020078923 scopus 로고
    • Unipolar sensing abnormalities: Incidence and clinical significance of skeletal muscle interference and undersensing in 228 patients
    • Secemsky SI, Hauser RG, Denes P, et al. Unipolar sensing abnormalities: Incidence and clinical significance of skeletal muscle interference and undersensing in 228 patients. PACE 1992; 5:10-19.
    • (1992) PACE , vol.5 , pp. 10-19
    • Secemsky, S.I.1    Hauser, R.G.2    Denes, P.3
  • 4
    • 0020405780 scopus 로고
    • Successful management of pacing system malfunctions without surgery: The role of programmable pulse generators
    • Billhardt RA, Rosenbush SW, Hauser RG. Successful management of pacing system malfunctions without surgery: The role of programmable pulse generators. PACE 1982; 5:675-682.
    • (1982) PACE , vol.5 , pp. 675-682
    • Billhardt, R.A.1    Rosenbush, S.W.2    Hauser, R.G.3
  • 5
    • 0020452032 scopus 로고
    • Ambulatory electrocardiography in the assessment of pacemaker function
    • Famularo MA, Kennedy HL. Ambulatory electrocardiography in the assessment of pacemaker function. Am Heart J 1982; 104:1086-1094.
    • (1982) Am Heart J , vol.104 , pp. 1086-1094
    • Famularo, M.A.1    Kennedy, H.L.2
  • 6
    • 0021917744 scopus 로고
    • Ambulatory electrocardiograms obtained by Holter monitoring system in patients with permanent demand pacemakers
    • Oka Y, Ito T, Sada T, et al. Ambulatory electrocardiograms obtained by Holter monitoring system in patients with permanent demand pacemakers. Jpn Heart J 1985; 26:23-32.
    • (1985) Jpn Heart J , vol.26 , pp. 23-32
    • Oka, Y.1    Ito, T.2    Sada, T.3
  • 7
    • 0023628403 scopus 로고
    • Utility of ambulatory electrocardiography in detecting pacemaker dysfunction in the early postimplantation period
    • Janosik DL, Redd RM, Buckingham TA. Utility of ambulatory electrocardiography in detecting pacemaker dysfunction in the early postimplantation period, Am J Cardiol 1987; 60:1030-1035.
    • (1987) Am J Cardiol , vol.60 , pp. 1030-1035
    • Janosik, D.L.1    Redd, R.M.2    Buckingham, T.A.3
  • 8
    • 0024217062 scopus 로고
    • Undersensing in VVI pacemakers detected by Holter monitoring
    • Van Gelder LM, El Gamal MIH. Undersensing in VVI pacemakers detected by Holter monitoring. PACE 1988; 11:1507-1511.
    • (1988) PACE , vol.11 , pp. 1507-1511
    • Van Gelder, L.M.1    El Gamal, M.I.H.2
  • 9
    • 0025633895 scopus 로고
    • Evaluation of rate-responsive pacemakers by transesophageal Holter monitoring of spontaneous atrial rate
    • Bongiorni MG, Soldati E, Paperini L, et al. Evaluation of rate-responsive pacemakers by transesophageal Holter monitoring of spontaneous atrial rate. PACE 1990; 13:1755-1760.
    • (1990) PACE , vol.13 , pp. 1755-1760
    • Bongiorni, M.G.1    Soldati, E.2    Paperini, L.3
  • 11
    • 0025896929 scopus 로고
    • Pacemaker generator pseudomalfunction: An artifact of Holter monitoring
    • Lesh MD, Langberg JJ, Griffin JC, et al. Pacemaker generator pseudomalfunction: An artifact of Holter monitoring. PACE 1991; 14:854-857.
    • (1991) PACE , vol.14 , pp. 854-857
    • Lesh, M.D.1    Langberg, J.J.2    Griffin, J.C.3
  • 12
    • 0024262704 scopus 로고
    • Analysis accuracy and susceptibility to faults of Holter functions in diagnostic pacemakers
    • Stangl K, Wirtzfeld A, Sichart U, et al. Analysis accuracy and susceptibility to faults of Holter functions in diagnostic pacemakers. PACE 1988; 11: 1708-1714.
    • (1988) PACE , vol.11 , pp. 1708-1714
    • Stangl, K.1    Wirtzfeld, A.2    Sichart, U.3
  • 13
    • 0025649046 scopus 로고
    • Usefulness of 1-hour and 24-hour heart rate Holter inbuilt in new TX* rate adaptive pacemakers
    • Sermasi S, Marconi M, Marzaloni M. Usefulness of 1-hour and 24-hour heart rate Holter inbuilt in new TX* rate adaptive pacemakers. PACE 1990; 13:1751-1754.
    • (1990) PACE , vol.13 , pp. 1751-1754
    • Sermasi, S.1    Marconi, M.2    Marzaloni, M.3
  • 14
    • 0029079516 scopus 로고
    • Diagnosis of ICD lead failure using cntinuous event marker recording
    • Horton RP, Canby RC, Román CA, et al. Diagnosis of ICD lead failure using cntinuous event marker recording. PACE 1995; 18:1331-1334.
    • (1995) PACE , vol.18 , pp. 1331-1334
    • Horton, R.P.1    Canby, R.C.2    Román, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.