메뉴 건너뛰기




Volumn 19, Issue 2, 1996, Pages 121-125

Immunometric assays and automation

Author keywords

Antibody specificity; Immunoassay automation; Immunometric assay; Labeled antibodies; Non isotopic immunoassay; Reflex testing

Indexed keywords

ANTIBODY LABELING; ANTIBODY SPECIFICITY; AUTOMATION; CLINICAL LABORATORY; IMMUNOASSAY; RADIOIMMUNOASSAY; REVIEW;

EID: 0029859313     PISSN: 10811672     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (15)
  • 1
    • 0002729023 scopus 로고
    • Towards immunoassays of greater sensitivity, specificity and speed: An overview
    • Albertini A, Ekins RP (eds): Elsevier/North Holland Biomedical Press, Amsterdam
    • Ekins RP: Towards immunoassays of greater sensitivity, specificity and speed: an overview, in Albertini A, Ekins RP (eds): Monoclonal antibodies and Developments in Immunoassay. Elsevier/North Holland Biomedical Press, Amsterdam 1981, pp 3-21.
    • (1981) Monoclonal Antibodies and Developments in Immunoassay , pp. 3-21
    • Ekins, R.P.1
  • 2
    • 0022644779 scopus 로고
    • Theoretical limitations on immunoassay sensitivity
    • Jackson TM: Theoretical limitations on immunoassay sensitivity. J Immunol Meth 1986;87:13-20.
    • (1986) J Immunol Meth , vol.87 , pp. 13-20
    • Jackson, T.M.1
  • 3
    • 10244265521 scopus 로고
    • Commercially available fully automated systems for radioligand assay
    • Chen IW: Commercially available fully automated systems for radioligand assay. Ligand Rev 1980;2:46.
    • (1980) Ligand Rev , vol.2 , pp. 46
    • Chen, I.W.1
  • 4
    • 10244274548 scopus 로고
    • Accuracy and precision in automated immunoassay systems
    • Wilson DW, Gaskell SJ, Griffiths K (eds). Alpha Omega, Cardiff
    • Woodhead JS, Simpson JSA, Davies SJ, et al: Accuracy and precision in automated immunoassay systems. In Wilson DW, Gaskell SJ, Griffiths K (eds). Quality Control in Clinical Endocrinology. Alpha Omega, Cardiff 1981, pp 117-125.
    • (1981) Quality Control in Clinical Endocrinology , pp. 117-125
    • Woodhead, J.S.1    Simpson, J.S.A.2    Davies, S.J.3
  • 7
    • 0344622441 scopus 로고
    • Optimisation of immunoradiometric (labelled antibody) immunoassays
    • Hunter WM, Corrie JET (eds) Churchill Livingstone, Edinburgh
    • Jackson TM, Marshall NJ, Ekins RP: Optimisation of immunoradiometric (labelled antibody) immunoassays. In Hunter WM, Corrie JET (eds) Immunoassays for Clinical Chemistry. Churchill Livingstone, Edinburgh 1983, pp 557-575.
    • (1983) Immunoassays for Clinical Chemistry , pp. 557-575
    • Jackson, T.M.1    Marshall, N.J.2    Ekins, R.P.3
  • 8
    • 0019257219 scopus 로고
    • Quality requirements of basal s-TSH assays in predicting an s-TSH response to TRH
    • Wide L, Dahlberg PA: Quality requirements of basal s-TSH assays in predicting an s-TSH response to TRH. Scand J Clin Lab Invest 1980;40: 101-110.
    • (1980) Scand J Clin Lab Invest , vol.40 , pp. 101-110
    • Wide, L.1    Dahlberg, P.A.2
  • 10
    • 0021397740 scopus 로고
    • The development of high sensitivity pulsed light, time-resolved fluoroimmunoassays
    • Ekins RP, Dakubu S: The development of high sensitivity pulsed light, time-resolved fluoroimmunoassays. Pure Appl Chem 1985;57:473-482.
    • (1985) Pure Appl Chem , vol.57 , pp. 473-482
    • Ekins, R.P.1    Dakubu, S.2
  • 11
    • 0007052945 scopus 로고    scopus 로고
    • Immunoassay design: The theory and the practice
    • Woodhead JS. Immunoassay design: the theory and the practice. J Clin Ligand Assay 1996;19(suppl)74-81.
    • (1996) J Clin Ligand Assay , vol.19 , Issue.SUPPL. , pp. 74-81
    • Woodhead, J.S.1
  • 12
    • 0027493487 scopus 로고
    • Impact of random-access automation on the immunoassay laboratory
    • Weinzierl C: Impact of random-access automation on the immunoassay laboratory. Lab Med 1993;24:717-723.
    • (1993) Lab Med , vol.24 , pp. 717-723
    • Weinzierl, C.1
  • 13
    • 0028072814 scopus 로고
    • High-performance assays of small molecules: Enhanced sensitivity, rapidity and convenience demonstrated with a noncompetitive immunometric anti-immune complex assay system for digoxin
    • Self CH, Dessi JL, Winger LA: High-performance assays of small molecules: enhanced sensitivity, rapidity and convenience demonstrated with a noncompetitive immunometric anti-immune complex assay system for digoxin. Clin Chem 1994; 40:2035-2041.
    • (1994) Clin Chem , vol.40 , pp. 2035-2041
    • Self, C.H.1    Dessi, J.L.2    Winger, L.A.3
  • 14
    • 10244255943 scopus 로고    scopus 로고
    • Microarray immunoassay and genosensor technologies: Recent developments
    • Ekins RP, Krause F, Chu F, et al: Microarray immunoassay and genosensor technologies: recent developments. J Clin Ligand Assay 1996; 19 (suppl) 64-73.
    • (1996) J Clin Ligand Assay , vol.19 , Issue.SUPPL. , pp. 64-73
    • Ekins, R.P.1    Krause, F.2    Chu, F.3
  • 15
    • 0024412288 scopus 로고
    • Assay formats involving acridinium-ester-labelled DNA probes
    • Arnold LJ, Hammond PW, Wiese WA, et al: Assay formats involving acridinium-ester-labelled DNA probes. Clin Chem 1989;35:1588-1594.
    • (1989) Clin Chem , vol.35 , pp. 1588-1594
    • Arnold, L.J.1    Hammond, P.W.2    Wiese, W.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.