메뉴 건너뛰기




Volumn 5, Issue SUPPL. 2, 1996, Pages

Long term biostability of polyacetal (Delrin®) implants

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; HEART VALVE PROSTHESIS; HIP PROSTHESIS; MECHANICAL STRESS; PRIORITY JOURNAL; PROSTHESIS MATERIAL; STRESS STRAIN RELATIONSHIP; TENSILE STRENGTH;

EID: 0029852004     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (10)
  • 1
    • 0016972816 scopus 로고
    • The friction and wear behaviour of polyoxymethylene in connection with joint replacement
    • Shen C, Dumbleton J. The friction and wear behaviour of polyoxymethylene in connection with joint replacement. Wear 1976;38:291-303
    • (1976) Wear , vol.38 , pp. 291-303
    • Shen, C.1    Dumbleton, J.2
  • 2
    • 0025235018 scopus 로고
    • Failure of the Christiansen hip. Survival analysis of 265 cases
    • Ohlin A. Failure of the Christiansen hip. Survival analysis of 265 cases. Acta Orthopaedica Scandinavica 1990;61:7-11
    • (1990) Acta Orthopaedica Scandinavica , vol.61 , pp. 7-11
    • Ohlin, A.1
  • 4
    • 10244270618 scopus 로고
    • E.I. Dupont de Nemours & Co.
    • Delrin® Handbook. E.I. Dupont de Nemours & Co., 1967
    • (1967) Delrin® Handbook
  • 5
    • 0027486304 scopus 로고
    • Evaluation of wear in an all- Polymer total knee replacement - Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces
    • McKellop H, Röstlund T, Bradley G. Evaluation of wear in an all- polymer total knee replacement - Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces. Clinical Materials 1993;14:117-126
    • (1993) Clinical Materials , vol.14 , pp. 117-126
    • McKellop, H.1    Röstlund, T.2    Bradley, G.3
  • 8
    • 85027472947 scopus 로고
    • Molecular structure of high molecular weight acetal resins
    • Koch TA, Lindvig PE. Molecular structure of high molecular weight acetal resins. J Applied Polymer Science 1959;1:164-168
    • (1959) J Applied Polymer Science , vol.1 , pp. 164-168
    • Koch, T.A.1    Lindvig, P.E.2
  • 9
    • 0343524301 scopus 로고
    • The wear of Delrin® 150 compared with polyethylene, polyester and PTFE
    • Hastings GW, Williams DF (eds). New York, John Wiley and Sons
    • Clarke I, McKellop H. The wear of Delrin® 150 compared with polyethylene, polyester and PTFE. In: Hastings GW, Williams DF (eds). Mechanical properties of biomaterials. New York, John Wiley and Sons, 1980:27-37
    • (1980) Mechanical Properties of Biomaterials , pp. 27-37
    • Clarke, I.1    McKellop, H.2
  • 10
    • 0019620861 scopus 로고
    • Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multi-channel screening device
    • McKellop H, Clarke I, Markolf K, Amstutz H. Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multi-channel screening device. J Biomed Mater Res 1981;15:619-653
    • (1981) J Biomed Mater Res , vol.15 , pp. 619-653
    • McKellop, H.1    Clarke, I.2    Markolf, K.3    Amstutz, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.