메뉴 건너뛰기




Volumn 28, Issue 10, 1996, Pages 527-534

Non-invasive monitoring of metabolites using near infrared spectroscopy: State of the art

Author keywords

assays for metabolites; blood glucose assay; in vivo monitoring; near infrared spectroscopy; non invasive; tissue spectroscopy

Indexed keywords

GLUCOSE;

EID: 0029851289     PISSN: 00185043     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-979846     Document Type: Review
Times cited : (78)

References (55)
  • 1
    • 84891699715 scopus 로고
    • Multivariate determination of glucose in whole blood using partial least-squares and artificial neural networks based on mid-infrared spectroscopy
    • Bhandare, P., Y. Mendelson, R. A. Peura, G. Janatsch, J. D. Kruse-Jarres, R. Marbach, H. M. Heise: Multivariate determination of glucose in whole blood using partial least-squares and artificial neural networks based on mid-infrared spectroscopy. Appl. Spectrosc. 47: 1214-121 (1993)
    • (1993) Appl. Spectrosc. , vol.47 , pp. 1214-2121
    • Bhandare, P.1    Mendelson, Y.2    Peura, R.A.3    Janatsch, G.4    Kruse-Jarres, J.D.5    Marbach, R.6    Heise, H.M.7
  • 2
    • 0000720391 scopus 로고
    • Multivariate calibration for protein, cholesterol and triglycerides using short-wave near infrared spectrometry
    • Bittner, A., R. Marbach, H. M. Heise: Multivariate calibration for protein, cholesterol and triglycerides using short-wave near infrared spectrometry. J. Mol. Struct. 349: 341-344 (1995)
    • (1995) J. Mol. Struct. , vol.349 , pp. 341-344
    • Bittner, A.1    Marbach, R.2    Heise, H.M.3
  • 3
    • 0009666492 scopus 로고    scopus 로고
    • Evaluation of microdialysis and FT-IR ATR-spectroscopy for in-vivo blood glucose monitoring
    • in press
    • Bittner, A., H. M. Heise, Th. Koschinsky, F. A. Gries: Evaluation of microdialysis and FT-IR ATR-spectroscopy for in-vivo blood glucose monitoring. Mikrochim. Acta, Suppl. 14: in press (1997)
    • (1997) Mikrochim. Acta, Suppl. , vol.14
    • Bittner, A.1    Heise, H.M.2    Koschinsky, Th.3    Gries, F.A.4
  • 4
    • 0000016091 scopus 로고    scopus 로고
    • In-vivo measurements of skin tissue by near-infrared diffuse relectance spectroscopy
    • in press
    • Bittner, A., S. Thomaßen, H. M. Heise: In-vivo measurements of skin tissue by near-infrared diffuse relectance spectroscopy. Mikrochim. Acta, Suppl. 14: in press (1997)
    • (1997) Mikrochim. Acta, Suppl. , vol.14
    • Bittner, A.1    Thomaßen, S.2    Heise, H.M.3
  • 5
    • 84989558331 scopus 로고
    • Secretion of glucose in human parotic saliva after carbohydrate intake
    • Borg, A., D. Birkhed: Secretion of glucose in human parotic saliva after carbohydrate intake. Scand. J. Dent. Res. 96: 551-556 (1988)
    • (1988) Scand. J. Dent. Res. , vol.96 , pp. 551-556
    • Borg, A.1    Birkhed, D.2
  • 6
    • 85035171451 scopus 로고    scopus 로고
    • Non-invasive pulsed infrared spectrophotometer. U. S. Patent 5,313,941 (24 May 1994)
    • Braig, J. R., D. S. Goldberger: Non-invasive pulsed infrared spectrophotometer. U. S. Patent 5,313,941 (24 May 1994)
    • Braig, J.R.1    Goldberger, D.S.2
  • 7
    • 0022980039 scopus 로고
    • Photophysical processes in recent medical laser developments: A review
    • Bulnois, J. L.: Photophysical processes in recent medical laser developments: a review. Lasers Med. Sci. 1: 47-66 (1986)
    • (1986) Lasers Med. Sci. , vol.1 , pp. 47-66
    • Bulnois, J.L.1
  • 8
    • 0026891886 scopus 로고
    • Non-invasive optical polarimetric glucose sensing technique using a true phase measurement technique
    • Cole, G. L., M. D. Fox, R. B. Northrop: Non-invasive optical polarimetric glucose sensing technique using a true phase measurement technique. IEEE Transact. Biomed. Eng. 39: 752-756 (1992)
    • (1992) IEEE Transact. Biomed. Eng. , vol.39 , pp. 752-756
    • Cole, G.L.1    Fox, M.D.2    Northrop, R.B.3
  • 10
    • 0028067965 scopus 로고
    • Clinical usefulness of the glucose concentration in the subcutaneous tissue - Properties and pittfalls of electrochemical biosensors
    • Fischer, U., K. Rebrin, T. v. Woedtke, P. Abel: Clinical usefulness of the glucose concentration in the subcutaneous tissue - properties and pittfalls of electrochemical biosensors. Horm. Metab. Res. 26: 515-522 (1994)
    • (1994) Horm. Metab. Res. , vol.26 , pp. 515-522
    • Fischer, U.1    Rebrin, K.2    Woedtke, T.V.3    Abel, P.4
  • 12
    • 0342688237 scopus 로고
    • Multivariate calibration applied to near-infrared spectroscopy for the quantitative analysis of dilute aqueous solutions
    • Haaland, D. M., H. D. T. Jones: Multivariate calibration applied to near-infrared spectroscopy for the quantitative analysis of dilute aqueous solutions. Proc. Soc. Photo-Opt. Instrum. Eng. (SPIE) 2089: 448-449 (1993)
    • (1993) Proc. Soc. Photo-Opt. Instrum. Eng. (SPIE) , vol.2089 , pp. 448-449
    • Haaland, D.M.1    Jones, H.D.T.2
  • 13
    • 0028405316 scopus 로고
    • Temperature insensitive near-infrared spectroscopic measurement of glucose in aqueous solutions
    • Hazen, K. H., M. A. Arnold, G. W. Small: Temperature insensitive near-infrared spectroscopic measurement of glucose in aqueous solutions. Appl. Spectrosc. 48: 477-483 (1994)
    • (1994) Appl. Spectrosc. , vol.48 , pp. 477-483
    • Hazen, K.H.1    Arnold, M.A.2    Small, G.W.3
  • 15
    • 0025860795 scopus 로고
    • Potential applications of infrared spectroscopy in clinical chemistry
    • Heise, H. M.: Potential applications of infrared spectroscopy in clinical chemistry. Lab. Med. 15: 470-476 (1991)
    • (1991) Lab. Med. , vol.15 , pp. 470-476
    • Heise, H.M.1
  • 17
    • 0000417922 scopus 로고
    • Blutglucoseanalytik - Stand und Perspektiven
    • Heise, H. M.: Blutglucoseanalytik - Stand und Perspektiven. Nachr. Chem. Techn. Lab. 41: 1100-1105 (1993)
    • (1993) Nachr. Chem. Techn. Lab. , vol.41 , pp. 1100-1105
    • Heise, H.M.1
  • 18
    • 0002511721 scopus 로고
    • Multicomponent assay for blood substrates in human plasma by mid-infrared spectroscopy and its evaluation for clinical analysis
    • Heise, H. M., R. Marbach, Th. Koschinsky, F. A. Gries: Multicomponent assay for blood substrates in human plasma by mid-infrared spectroscopy and its evaluation for clinical analysis. Appl. Spectrosc. 48: 85-95 (1994)
    • (1994) Appl. Spectrosc. , vol.48 , pp. 85-95
    • Heise, H.M.1    Marbach, R.2    Koschinsky, Th.3    Gries, F.A.4
  • 19
    • 0028309433 scopus 로고
    • Non-invasive blood glucose sensors based on near-infrared spectroscopy
    • Heise, H. M., R. Marbach, Th. Koschinsky, F. A. Gries: Non-invasive blood glucose sensors based on near-infrared spectroscopy. Artificial Organs 18: 439-447 (1994)
    • (1994) Artificial Organs , vol.18 , pp. 439-447
    • Heise, H.M.1    Marbach, R.2    Koschinsky, Th.3    Gries, F.A.4
  • 20
    • 0001929814 scopus 로고    scopus 로고
    • Medical applications of infrared spectroscopy
    • in press
    • Heise, H. M.: Medical applications of infrared spectroscopy. Mikrochim. Acta, Suppl. 14: in press (1997)
    • (1997) Mikrochim. Acta, Suppl. , vol.14
    • Heise, H.M.1
  • 22
    • 0000924710 scopus 로고    scopus 로고
    • Biomedical Infrared Spectroscopy
    • H. H. Mantsch and D. Chapman (eds.), Wiley-Liss, Inc., New York
    • Jackson, M., H. H. Mantsch: Biomedical Infrared Spectroscopy. In: Infrared Spectroscopy of Biomolecules. H. H. Mantsch and D. Chapman (eds.), Wiley-Liss, Inc., New York (1996), pp. 311-340
    • (1996) Infrared Spectroscopy of Biomolecules , pp. 311-340
    • Jackson, M.1    Mantsch, H.H.2
  • 23
    • 0028842373 scopus 로고
    • Recent advances in amperometric glucose biosensors for in vivo monitoring
    • Jaffari, S. A., A. P. F. Turner: Recent advances in amperometric glucose biosensors for in vivo monitoring. Physiol. Meas. 16: 1-15 (1995)
    • (1995) Physiol. Meas. , vol.16 , pp. 1-15
    • Jaffari, S.A.1    Turner, A.P.F.2
  • 24
    • 0000970054 scopus 로고
    • Application of near-infrared spectroscopy for non-invasive determination of blood/tissue glucose using neural networks
    • Jagemann, K.-U., C. Fischbacher, K. Danzer, U. A. Müller, B. Mertes: Application of near-infrared spectroscopy for non-invasive determination of blood/tissue glucose using neural networks. Z. Phys. Chem. 191: 179-190 (1995)
    • (1995) Z. Phys. Chem. , vol.191 , pp. 179-190
    • Jagemann, K.-U.1    Fischbacher, C.2    Danzer, K.3    Müller, U.A.4    Mertes, B.5
  • 25
    • 0024731130 scopus 로고
    • Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma
    • Janatsch, G., J. D. Kruse-Jarres, R. Marbach, H. M. Heise: Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma. Anal. Chem. 61: 2016-2023 (1989)
    • (1989) Anal. Chem. , vol.61 , pp. 2016-2023
    • Janatsch, G.1    Kruse-Jarres, J.D.2    Marbach, R.3    Heise, H.M.4
  • 27
    • 0026354548 scopus 로고
    • Combination of microdialysis and glucosensor permits continuous (on-line) s.c. glucose monitoring in a patient operated device: In-vitro evaluation
    • Keck, F., W. Kerner, C. Meyerhoff, H. Zier, E. F. Pfeiffer: Combination of microdialysis and glucosensor permits continuous (on-line) s.c. glucose monitoring in a patient operated device: in-vitro evaluation. Horm. Metab. Res. 23: 617-618 (1991)
    • (1991) Horm. Metab. Res. , vol.23 , pp. 617-618
    • Keck, F.1    Kerner, W.2    Meyerhoff, C.3    Zier, H.4    Pfeiffer, E.F.5
  • 28
    • 0026733786 scopus 로고
    • Combination of microdialysis and glucosensor permits continuous (on-line) s.c. glucose monitoring in a patient operated device: In-vivo evaluation
    • Keck, F., C. Meyerhoff, W. Kerner, T. Sigmund, H. Zier, E. F. Pfeifer: Combination of microdialysis and glucosensor permits continuous (on-line) s.c. glucose monitoring in a patient operated device: in-vivo evaluation. Horm. Metab. Res. 24: 492-493 (1992)
    • (1992) Horm. Metab. Res. , vol.24 , pp. 492-493
    • Keck, F.1    Meyerhoff, C.2    Kerner, W.3    Sigmund, T.4    Zier, H.5    Pfeifer, E.F.6
  • 30
    • 0027746317 scopus 로고
    • The function of a hydrogen peroxyde-detecting electroenzymatic glucose is markedly impaired in human subcutaneous tissue and plasma
    • Kerner, W., M. Kiwit, B. Linke, F. S. Keck, H. Zier, E. F. Pfeiffer: The function of a hydrogen peroxyde-detecting electroenzymatic glucose is markedly impaired in human subcutaneous tissue and plasma. Biosensors & Bioelectronics 8: 473-482 (1993)
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 473-482
    • Kerner, W.1    Kiwit, M.2    Linke, B.3    Keck, F.S.4    Zier, H.5    Pfeiffer, E.F.6
  • 32
    • 0028730887 scopus 로고
    • Influence of glucose concentration on light scattering in tissue-simulating phantoms
    • Kohl, M., M. Cope, M. Essenpreis, D. Böcker: Influence of glucose concentration on light scattering in tissue-simulating phantoms. Optics Letters 19: 2170-2172 (1994)
    • (1994) Optics Letters , vol.19 , pp. 2170-2172
    • Kohl, M.1    Cope, M.2    Essenpreis, M.3    Böcker, D.4
  • 33
    • 0023714852 scopus 로고
    • New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose
    • Koschinsky, T., K. Dannehl, F. A. Gries: New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care 11: 619-629 (1988)
    • (1988) Diabetes Care , vol.11 , pp. 619-629
    • Koschinsky, T.1    Dannehl, K.2    Gries, F.A.3
  • 34
    • 10344247819 scopus 로고
    • A portable blood glucose monitoring system
    • Kuryama, T.: A portable blood glucose monitoring system. Proc. Electrochem. Soc. 9414: 10-16 (1994)
    • (1994) Proc. Electrochem. Soc. , vol.9414 , pp. 10-16
    • Kuryama, T.1
  • 35
    • 0001912354 scopus 로고
    • Near-IR fiber-optic temperature sensor
    • Lin, J., C. W. Brown: Near-IR fiber-optic temperature sensor. Appl. Spectrosc. 47:62-68 (1993)
    • (1993) Appl. Spectrosc. , vol.47 , pp. 62-68
    • Lin, J.1    Brown, C.W.2
  • 36
    • 0000804634 scopus 로고
    • Spectroscopic measurement of NaCl and sea water salinity in the near-IR region of 680-1230 nm
    • Lin, J., C. W. Brown: Spectroscopic measurement of NaCl and sea water salinity in the near-IR region of 680-1230 nm. Appl. Spectrosc. 47: 239-241 (1993)
    • (1993) Appl. Spectrosc. , vol.47 , pp. 239-241
    • Lin, J.1    Brown, C.W.2
  • 37
    • 0027560887 scopus 로고
    • Chemical in-vivo monitoring by optical sensors in medicine
    • Lübbers, D. W.: Chemical in-vivo monitoring by optical sensors in medicine. Sensors and Actuators B 11: 253-262 (1993)
    • (1993) Sensors and Actuators B , vol.11 , pp. 253-262
    • Lübbers, D.W.1
  • 38
    • 0002341431 scopus 로고
    • Water - The most anomalous liquid
    • P. L. Huyskens, W. A. P. Luck, T. Zeegers-Huyskens (eds.); Springer Verlag, Berlin
    • Luck, W. A. P.: Water - the most anomalous liquid. In: Intermolecular Forces. P. L. Huyskens, W. A. P. Luck, T. Zeegers-Huyskens (eds.); Springer Verlag, Berlin (1991), pp. 217-249
    • (1991) Intermolecular Forces , pp. 217-249
    • Luck, W.A.P.1
  • 39
    • 0028731080 scopus 로고
    • Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared
    • Maier, J. S., S. A. Walker, S. Fantini, M. A. Franceschini, E. Gratton: Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared. Optics Letters 19: 2062-2064 (1994)
    • (1994) Optics Letters , vol.19 , pp. 2062-2064
    • Maier, J.S.1    Walker, S.A.2    Fantini, S.3    Franceschini, M.A.4    Gratton, E.5
  • 40
    • 0008688714 scopus 로고
    • Meßverfahren zur IR-spectrometrischen Blutglucosebestimmung
    • VDI-Verlag, Düsseldorf
    • Marbach, R.: Meßverfahren zur IR-spectrometrischen Blutglucosebestimmung. Fortschr. Ber. VDI Ser. 8, Vol. 346, VDI-Verlag, Düsseldorf (1993)
    • (1993) Fortschr. Ber. VDI Ser. 8 , vol.346
    • Marbach, R.1
  • 41
    • 84891711974 scopus 로고
    • Noninvasive blood glucose assay by near infrared diffuse reflectance spectroscopy of the human inner lip
    • Marbach, R., T. Koschinsky, F. A. Gries, H. M. Heise: Noninvasive blood glucose assay by near infrared diffuse reflectance spectroscopy of the human inner lip. Appl. Spectrosc. 47: 875-881 (1993)
    • (1993) Appl. Spectrosc. , vol.47 , pp. 875-881
    • Marbach, R.1    Koschinsky, T.2    Gries, F.A.3    Heise, H.M.4
  • 42
    • 0029251433 scopus 로고
    • Optical diffuse reflectance accessory for measurements of skin tissue by near-infrared spectroscopy
    • Marbach, R., H. M. Heise: Optical diffuse reflectance accessory for measurements of skin tissue by near-infrared spectroscopy. Appl. Optics 34: 610-621 (1995)
    • (1995) Appl. Optics , vol.34 , pp. 610-621
    • Marbach, R.1    Heise, H.M.2
  • 43
    • 0028081969 scopus 로고
    • Use of water absorption spectrum to quantify tissue chromophore concentration changes in near-infrared spectroscopy
    • Matcher, S. J., M. Cope, D. T. Delpy: Use of water absorption spectrum to quantify tissue chromophore concentration changes in near-infrared spectroscopy. Phys. Med. Biol. 38: 177-196 (1993)
    • (1993) Phys. Med. Biol. , vol.38 , pp. 177-196
    • Matcher, S.J.1    Cope, M.2    Delpy, D.T.3
  • 44
    • 0026761167 scopus 로고
    • On-line continuous monitoring of s.c. tissue glucose in men by combining a portable glucosensor with microdialysis
    • Meyerhoff, C., F. Bischof, F. Sternberg, H. Zier, E. F. Pfeiffer: On-line continuous monitoring of s.c. tissue glucose in men by combining a portable glucosensor with microdialysis. Diabetologia 35: 1087-1092 (1992)
    • (1992) Diabetologia , vol.35 , pp. 1087-1092
    • Meyerhoff, C.1    Bischof, F.2    Sternberg, F.3    Zier, H.4    Pfeiffer, E.F.5
  • 45
    • 0028109468 scopus 로고
    • Combination of microdialysis and glucosensor for continuous measurement of the s.c. glucose concentration: Theory and practical application
    • Meyerhoff, C., F. J. Mennel, F. Bischof, F. Sternberg, E. F. Pfeiffer: Combination of microdialysis and glucosensor for continuous measurement of the s.c. glucose concentration: Theory and practical application. Horm. Metab. Res. 26: 538-543 (1994)
    • (1994) Horm. Metab. Res. , vol.26 , pp. 538-543
    • Meyerhoff, C.1    Mennel, F.J.2    Bischof, F.3    Sternberg, F.4    Pfeiffer, E.F.5
  • 46
    • 1842370264 scopus 로고
    • The artificial pancreas
    • Rifkin, H., Colwell, J. A., Taylor, S. I. (eds.); Elsevier Science Publ, B. V., New York
    • Pfeiffer, E. F.: The artificial pancreas. In: Diabetes 1991, Rifkin, H., Colwell, J. A., Taylor, S. I. (eds.); Elsevier Science Publ, B. V., New York (1991), pp. 919-935
    • (1991) Diabetes 1991 , pp. 919-935
    • Pfeiffer, E.F.1
  • 47
    • 0027474090 scopus 로고
    • On-line continuous monitoring of s.c. tissue glucose is feasible by combining portable glucosensor with microdialysis
    • Pfeiffer, E. F., C. Meyerhoff, F. Bischof, F. S. Keck, W. Kerner: On-line continuous monitoring of s.c. tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm. Metab. Res. 25: 121-124 (1993)
    • (1993) Horm. Metab. Res. , vol.25 , pp. 121-124
    • Pfeiffer, E.F.1    Meyerhoff, C.2    Bischof, F.3    Keck, F.S.4    Kerner, W.5
  • 48
    • 0028350855 scopus 로고
    • Development of a glucosensor for glucose monitoring in man: The disposable implant concept
    • Poitout, V., D. Moatti Sirat, G. Reach: Development of a glucosensor for glucose monitoring in man: the disposable implant concept. Clin. Materials 15: 241-246 (1994)
    • (1994) Clin. Materials , vol.15 , pp. 241-246
    • Poitout, V.1    Moatti Sirat, D.2    Reach, G.3
  • 49
    • 0027754155 scopus 로고
    • Glucose determination by a pulsed photo-acoustic technique: An experimental study using a gelatin-based tissue phantom
    • Quan, K. M., G. B. Christison, H. A. MacKenzie, P. Hodgson: Glucose determination by a pulsed photo-acoustic technique: an experimental study using a gelatin-based tissue phantom. Phys. Med. Biol. 38: 1911-1922 (1993)
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1911-1922
    • Quan, K.M.1    Christison, G.B.2    MacKenzie, H.A.3    Hodgson, P.4
  • 51
    • 0020402631 scopus 로고
    • Wearable artificial pancreas with needle-type glucosensor
    • Shichiri, M., R. Kawamori, Y. Yamasaki, N. Hakui: Wearable artificial pancreas with needle-type glucosensor. The Lancet 46: 1129-1131 (1982)
    • (1982) The Lancet , vol.46 , pp. 1129-1131
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3    Hakui, N.4
  • 52
    • 0028168357 scopus 로고
    • Kromoscopic analysis: A possible alternative to spectroscopic analysis for noninvasive measurement of analytes in-vivo
    • Sodickson, L. A., M. J. Block: Kromoscopic analysis: A possible alternative to spectroscopic analysis for noninvasive measurement of analytes in-vivo. Clin. Chem. 40: 1838-1844 (1994)
    • (1994) Clin. Chem. , vol.40 , pp. 1838-1844
    • Sodickson, L.A.1    Block, M.J.2
  • 53
    • 0029101233 scopus 로고
    • Subcutaneous glucose concentration: Its real estimation and continuous monitoring
    • Sternberg, F., C. Meyerhoff, F. J. Mennel, F. Bischof, E. F. Pfeiffer: Subcutaneous glucose concentration: its real estimation and continuous monitoring. Diabetes Care 18: 1266-1269 (1995)
    • (1995) Diabetes Care , vol.18 , pp. 1266-1269
    • Sternberg, F.1    Meyerhoff, C.2    Mennel, F.J.3    Bischof, F.4    Pfeiffer, E.F.5
  • 55
    • 0028823945 scopus 로고
    • Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
    • Tamada, J. A., N. J. V. Bohannon, R. O. Potts: Measurement of glucose in diabetic subjects using noninvasive transdermal extraction. Nature Medicine 1: 1198-1201 (1995)
    • (1995) Nature Medicine , vol.1 , pp. 1198-1201
    • Tamada, J.A.1    Bohannon, N.J.V.2    Potts, R.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.