메뉴 건너뛰기




Volumn 22, Issue 6, 1996, Pages 747-766

A Doppler ultrasound clutter phantom

Author keywords

Clutter; Doppler sensitivity; Doppler ultrasound; Doppler ultrasound evaluation; Quality assurance; Wall filter

Indexed keywords

BLOOD; BLOOD VESSELS; DOPPLER EFFECT; HEMODYNAMICS; ULTRASONIC IMAGING; VELOCITY MEASUREMENT;

EID: 0029847281     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/0301-5629(96)00045-2     Document Type: Article
Times cited : (11)

References (18)
  • 1
    • 0023933332 scopus 로고
    • Performance tests of Doppler ultrasound equipment with a tissue and blood-mimicking phantom
    • Boote EJ, Zagzebski A. Performance tests of Doppler ultrasound equipment with a tissue and blood-mimicking phantom. J Ultrasound Med 1988;7:137-147.
    • (1988) J Ultrasound Med , vol.7 , pp. 137-147
    • Boote, E.J.1    Zagzebski, A.2
  • 2
    • 0026157247 scopus 로고
    • Accuracy of colour Doppler ultrasound velocity measurements in small vessels
    • Deane CR, Forsberg F, Thomas N, Roberts VC. Accuracy of colour Doppler ultrasound velocity measurements in small vessels. J Biomed Eng 1991;13:249-254.
    • (1991) J Biomed Eng , vol.13 , pp. 249-254
    • Deane, C.R.1    Forsberg, F.2    Thomas, N.3    Roberts, V.C.4
  • 10
    • 0025100021 scopus 로고
    • On the behavior of instantaneous frequency estimators implemented on Doppler flow imagers
    • Nowicki A, Reid J, Pedersen PC, Schmidt AW, Oung H. On the behavior of instantaneous frequency estimators implemented on Doppler flow imagers. Ultrasound Med Biol 1990;16:511-518.
    • (1990) Ultrasound Med Biol , vol.16 , pp. 511-518
    • Nowicki, A.1    Reid, J.2    Pedersen, P.C.3    Schmidt, A.W.4    Oung, H.5
  • 16
    • 0026734703 scopus 로고
    • Velocity evaluation phantom for colour and pulsed Doppler instruments
    • Rickey DW, Rankin R, Fenster A. Velocity evaluation phantom for colour and pulsed Doppler instruments. Ultrasound Med Biol 1992;18:479-494.
    • (1992) Ultrasound Med Biol , vol.18 , pp. 479-494
    • Rickey, D.W.1    Rankin, R.2    Fenster, A.3
  • 17
    • 0022160739 scopus 로고
    • Ultrasonic characterization of biological tissues
    • Shung KK. Ultrasonic characterization of biological tissues. J Biomech Eng 1985;107:309-314.
    • (1985) J Biomech Eng , vol.107 , pp. 309-314
    • Shung, K.K.1
  • 18
    • 0024380426 scopus 로고
    • Bias and variance in the estimate of the Doppler frequency induced by a wall motion filter
    • Willemetz JC, Nowicki A, Meister JJ, De Palma F, Pante G. Bias and variance in the estimate of the Doppler frequency induced by a wall motion filter. Ultrason Imag 1989;11:215-225.
    • (1989) Ultrason Imag , vol.11 , pp. 215-225
    • Willemetz, J.C.1    Nowicki, A.2    Meister, J.J.3    De Palma, F.4    Pante, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.