메뉴 건너뛰기




Volumn 42, Issue 12, 1996, Pages 1901-1910

Robotics and the changing face of the clinical laboratory

Author keywords

artificial intelligence; automation; computers; simulation modeling; standardization; systems engineering

Indexed keywords

ARTIFICIAL INTELLIGENCE; AUTOANALYSIS; AUTOMATION; BIOMEDICAL ENGINEERING; CLINICAL LABORATORY; COMPUTER SIMULATION; COMPUTER SYSTEM; REVIEW; ROBOTICS; STANDARD; SYSTEM ANALYSIS;

EID: 0029844964     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.12.1901     Document Type: Review
Times cited : (40)

References (30)
  • 1
    • 0025993095 scopus 로고
    • An innovative conveyor belt system for a clinical laboratory
    • Sasaki M. An innovative conveyor belt system for a clinical laboratory. J Int Fed Clin Chem 1991;3:31-3.
    • (1991) J Int Fed Clin Chem , vol.3 , pp. 31-33
    • Sasaki, M.1
  • 2
    • 0027136761 scopus 로고
    • A fully automated clinical laboratory
    • Sasaki M. A fully automated clinical laboratory. Lab Info Manage 1993;21:159-68.
    • (1993) Lab Info Manage , vol.21 , pp. 159-168
    • Sasaki, M.1
  • 3
    • 0025066403 scopus 로고
    • A fully robotic assay for human hormone analysis
    • Sasaki M, Ogura K. A fully robotic assay for human hormone analysis. Clin Chem 1990;36:1567-71.
    • (1990) Clin Chem , vol.36 , pp. 1567-1571
    • Sasaki, M.1    Ogura, K.2
  • 4
    • 0013594538 scopus 로고
    • How to make and manage clinical laboratory systems using robotic facilities
    • Okuda K, ed. Oxford: Blackwell Scientific Publications
    • Sasaki M. How to make and manage clinical laboratory systems using robotic facilities. In Okuda K, ed. Automation and new technology in the clinical laboratory. Oxford: Blackwell Scientific Publications, 1990:97-101.
    • (1990) Automation and New Technology in the Clinical Laboratory , pp. 97-101
    • Sasaki, M.1
  • 6
    • 0028871069 scopus 로고
    • Robotics in the hematology laboratory. An evaluation of the productivity of the Sysmex HS-330
    • Rothe M, Wingfield S, Barranco P, Charache S. Robotics in the hematology laboratory. An evaluation of the productivity of the Sysmex HS-330. Am J Clin Pathol 1995;103:154-8.
    • (1995) Am J Clin Pathol , vol.103 , pp. 154-158
    • Rothe, M.1    Wingfield, S.2    Barranco, P.3    Charache, S.4
  • 7
    • 0029361136 scopus 로고
    • Effective use of robots as mechanized couriers at Stanford University Hospital
    • Prasad P. Effective use of robots as mechanized couriers at Stanford University Hospital. Biomed Instrum Technol 1995;29: 398-404.
    • (1995) Biomed Instrum Technol , vol.29 , pp. 398-404
    • Prasad, P.1
  • 8
    • 0000293181 scopus 로고    scopus 로고
    • Automation of preanalytical processing and mobile robotics
    • Kost GJ, ed. New York: John Wiley & Sons
    • Felder RA. Automation of preanalytical processing and mobile robotics. In: Kost GJ, ed. Handbook of clinical automation, robotics and optimization. New York: John Wiley & Sons, 1996:252-82.
    • (1996) Handbook of Clinical Automation, Robotics and Optimization , pp. 252-282
    • Felder, R.A.1
  • 11
    • 10544242449 scopus 로고
    • The laboratory robotics evolution: A survey of today's robot options
    • Strimaitis JR, Hawk GL, eds. Hopkinton, MA: Zymark Corp.
    • Schmidt WA, Rollheiser JJ, Stelting KM. The laboratory robotics evolution: a survey of today's robot options. In: Strimaitis JR, Hawk GL, eds. Advances in laboratory automation - robotics, Vol. 5, Hopkinton, MA: Zymark Corp., 1989:479-501.
    • (1989) Advances in Laboratory Automation - Robotics , vol.5 , pp. 479-501
    • Schmidt, W.A.1    Rollheiser, J.J.2    Stelting, K.M.3
  • 12
    • 0027386780 scopus 로고
    • Robotic chromatography: Development and evaluation of automated instrumentation for assay of glycohemoglobin
    • Herold CD, Andree K, Herold DA, Felder RA. Robotic chromatography: development and evaluation of automated instrumentation for assay of glycohemoglobin. Clin Chem 1993;39:143-7.
    • (1993) Clin Chem , vol.39 , pp. 143-147
    • Herold, C.D.1    Andree, K.2    Herold, D.A.3    Felder, R.A.4
  • 13
    • 10544250932 scopus 로고
    • Use of a robotic arm for specimen handling in a remote, unmanned clinical chemistry laboratory
    • Boyd JC, Felder RA, Margrey KS, Martinez A, Savory J. Use of a robotic arm for specimen handling in a remote, unmanned clinical chemistry laboratory. Clin Chem 1987;33:1560-1.
    • (1987) Clin Chem , vol.33 , pp. 1560-1561
    • Boyd, J.C.1    Felder, R.A.2    Margrey, K.S.3    Martinez, A.4    Savory, J.5
  • 16
    • 0029338991 scopus 로고
    • Total laboratory automation: A view of the 21st century
    • Bauer S, Teplitz C. Total laboratory automation: a view of the 21st century. Med Lab Observ 1995;7(7):22-5.
    • (1995) Med Lab Observ , vol.7 , Issue.7 , pp. 22-25
    • Bauer, S.1    Teplitz, C.2
  • 17
    • 0029377344 scopus 로고
    • Total lab automation: System design
    • Bauer S, Teplitz C. Total lab automation: system design. Med Lab Observ 1995;7(9):44-50.
    • (1995) Med Lab Observ , vol.7 , Issue.9 , pp. 44-50
    • Bauer, S.1    Teplitz, C.2
  • 19
    • 10544224015 scopus 로고
    • Laboratory computer networking
    • Deming RL, Young LA. Laboratory computer networking. Sci Comput Autom 1989;5(4):21-5.
    • (1989) Sci Comput Autom , vol.5 , Issue.4 , pp. 21-25
    • Deming, R.L.1    Young, L.A.2
  • 25
    • 0028093606 scopus 로고
    • The development of a decision support system for the pathological diagnosis of human cerebral tumours based on a neural network classifier
    • Wien
    • Sieben G, Praet M, Roels H, Otte G, Boullart L, Calliauw L. The development of a decision support system for the pathological diagnosis of human cerebral tumours based on a neural network classifier. Acta Neurochir (Wien) 1994;129:193-7.
    • (1994) Acta Neurochir , vol.129 , pp. 193-197
    • Sieben, G.1    Praet, M.2    Roels, H.3    Otte, G.4    Boullart, L.5    Calliauw, L.6
  • 26
    • 0024406279 scopus 로고
    • Structured alarm systems for the operating room
    • Schreiber PJ, Schreiber J. Structured alarm systems for the operating room. J Clin Monit 1989;5:201-4.
    • (1989) J Clin Monit , vol.5 , pp. 201-204
    • Schreiber, P.J.1    Schreiber, J.2
  • 27
    • 0027172837 scopus 로고
    • PIERS: A pathologist-maintained expert system for the interpretation of chemical pathology reports
    • Edwards G, Compton P, Malor R, Srinivasan A, Lazarus L. PIERS: a pathologist-maintained expert system for the interpretation of chemical pathology reports. Pathology 1993;25:27-34.
    • (1993) Pathology , vol.25 , pp. 27-34
    • Edwards, G.1    Compton, P.2    Malor, R.3    Srinivasan, A.4    Lazarus, L.5
  • 28
    • 0002895587 scopus 로고
    • Use of artificial intelligence in analytical systems for the clinical laboratory
    • Place JF, Truchaud A, Ozawa K, Pardue H, Schnipelsky P (IFCC Committee on Analytical Systems). Use of artificial intelligence in analytical systems for the clinical laboratory. Clin Chim Acta 1994;231:S5-S34.
    • (1994) Clin Chim Acta , vol.231
    • Place, J.F.1    Truchaud, A.2    Ozawa, K.3    Pardue, H.4    Schnipelsky, P.5
  • 29
    • 0029317972 scopus 로고
    • Key trends in cost containment
    • Clinical Laboratory Information Council. Key trends in cost containment. Med Lab Observ 1995;27(6):30-3.
    • (1995) Med Lab Observ , vol.27 , Issue.6 , pp. 30-33
  • 30
    • 0029134781 scopus 로고
    • Value-added laboratory medicine in an era of managed care
    • McDonald JM, Smith JA. Value-added laboratory medicine in an era of managed care. Clin Chem 1995;41:1256-62.
    • (1995) Clin Chem , vol.41 , pp. 1256-1262
    • McDonald, J.M.1    Smith, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.