메뉴 건너뛰기




Volumn 15, Issue 3, 1996, Pages 236-239

Dilatation of aorto-bifemoral knitted Dacron grafts after a mean implantation of 5 years

Author keywords

Aorto bifemoral bypass surgery; Computed tomography scanners; Dilatation

Indexed keywords

ADULT; AGED; AORTOFEMORAL BYPASS; ARTERY DIAMETER; ARTERY DILATATION; ARTICLE; BYPASS SURGERY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DACRON IMPLANT; FEMALE; FOLLOW UP; HUMAN; MALE; THROMBUS;

EID: 0029844757     PISSN: 03929590     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0028277457 scopus 로고
    • Dilatation of woven and knitted aortic prosthetic grafts: CT scan evaluation
    • Alimi Y, Juhan C, Morati N, Girard N, Cohen S. Dilatation of woven and knitted aortic prosthetic grafts: CT scan evaluation. Ann Vasc Surg 1994;8:238-42.
    • (1994) Ann Vasc Surg , vol.8 , pp. 238-242
    • Alimi, Y.1    Juhan, C.2    Morati, N.3    Girard, N.4    Cohen, S.5
  • 3
    • 0020586157 scopus 로고
    • Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysms: Etiologic considerations
    • Clagett GP, Salander JM, Eddleman WL et al. Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysms: etiologic considerations. Surgery 1983;93:9-16.
    • (1983) Surgery , vol.93 , pp. 9-16
    • Clagett, G.P.1    Salander, J.M.2    Eddleman, W.L.3
  • 4
    • 0018573665 scopus 로고
    • Dilation of synthetic grafts and junctional aneurysms
    • Kim GE, Imparato AM, Nathan I, Riles TS. Dilation of synthetic grafts and junctional aneurysms. Arch Surg 1979;114:1296-303.
    • (1979) Arch Surg , vol.114 , pp. 1296-1303
    • Kim, G.E.1    Imparato, A.M.2    Nathan, I.3    Riles, T.S.4
  • 6
    • 0025126536 scopus 로고
    • Postoperative dilation of knitted Dacron aortic bifurcation graft
    • Nunn DB, Carter MM, Donohue MT, Hudgins PC. Postoperative dilation of knitted Dacron aortic bifurcation graft. J Vasc Surg 1990;12:291-7.
    • (1990) J Vasc Surg , vol.12 , pp. 291-297
    • Nunn, D.B.1    Carter, M.M.2    Donohue, M.T.3    Hudgins, P.C.4
  • 7
    • 0018772816 scopus 로고
    • Postoperative alterations in size of Dacron aortic grafts. An ultrasonic evaluation
    • Nunn DB, Freeman MH, Hudgins PC. Postoperative alterations in size of Dacron aortic grafts. An ultrasonic evaluation. Ann Surg 1979;189:741-4.
    • (1979) Ann Surg , vol.189 , pp. 741-744
    • Nunn, D.B.1    Freeman, M.H.2    Hudgins, P.C.3
  • 8
    • 0019487784 scopus 로고
    • Pathogenesis of anastomotic aneurysms
    • Gaylis H. Pathogenesis of anastomotic aneurysms. Surgery 1981;90:509-15.
    • (1981) Surgery , vol.90 , pp. 509-515
    • Gaylis, H.1
  • 9
    • 0021777169 scopus 로고
    • Late rupture of knitted Dacron double velour arterial prostheses. Report on four cases
    • Trippestad A. Late rupture of knitted Dacron double velour arterial prostheses. Report on four cases. Acta Chir Scand 1985;151:391-5.
    • (1985) Acta Chir Scand , vol.151 , pp. 391-395
    • Trippestad, A.1
  • 10
    • 0022691602 scopus 로고
    • On the correlation between the failure of vascular grafts and their structural and material properties: A critical analysis
    • Pourdeyhimi B, Wagner D. On the correlation between the failure of vascular grafts and their structural and material properties: a critical analysis. J Biomed Mat Res 1986;20:375-409.
    • (1986) J Biomed Mat Res , vol.20 , pp. 375-409
    • Pourdeyhimi, B.1    Wagner, D.2
  • 12
    • 0025131148 scopus 로고
    • End-to-side aorto prosthetic anastomoses; long-term computed tomography assessment
    • Mikati A, Murache P, Watel A et al. End-to-side aorto prosthetic anastomoses; long-term computed tomography assessment. Ann Vasc Surg 1990;4:584-91.
    • (1990) Ann Vasc Surg , vol.4 , pp. 584-591
    • Mikati, A.1    Murache, P.2    Watel, A.3
  • 13
    • 0024446623 scopus 로고
    • Anastomotic aneurysms - An underdiagnosed complication after aorto-iliac reconstructions
    • Sieswerda C, Skotnicki SH, Barentsz JO, Heystraten FMJ, Anastomotic aneurysms - an underdiagnosed complication after aorto-iliac reconstructions. Eur J Vase Surg 1989;3:233-8.
    • (1989) Eur J Vase Surg , vol.3 , pp. 233-238
    • Sieswerda, C.1    Skotnicki, S.H.2    Barentsz, J.O.3    Heystraten, F.M.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.