메뉴 건너뛰기




Volumn 65, Issue 1-4, 1996, Pages 213-215

Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV

Author keywords

[No Author keywords available]

Indexed keywords

COPPER DERIVATIVE; LITHIUM FLUORIDE; MAGNESIUM DERIVATIVE; PHOSPHORUS DERIVATIVE; TITANIUM DERIVATIVE;

EID: 0029835318     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031625     Document Type: Conference Paper
Times cited : (8)

References (10)
  • 2
    • 0028419982 scopus 로고
    • Supralinearity and Sensitization of the Thermoluminescence. Part I: A Theoretical Treatment Based on an Interactive Trap System
    • Sunta, C. M., Yoshimura, E. M. and Okuno, E. Supralinearity and Sensitization of the Thermoluminescence. Part I: a Theoretical Treatment Based on an Interactive Trap System. J. Phys. D: Appl. Phys. 27, 852-860 (1994).
    • (1994) J. Phys. D: Appl. Phys. , vol.27 , pp. 852-860
    • Sunta, C.M.1    Yoshimura, E.M.2    Okuno, E.3
  • 3
    • 0027701124 scopus 로고
    • Supralinearity of the Thermoluminescence Glow-peak 5 of LiF (TLD-700) Obtained with Isothermal Measurements
    • Kitis, G., Charalambous, S. and Tuyn, J. W. N. Supralinearity of the Thermoluminescence Glow-peak 5 of LiF (TLD-700) Obtained with Isothermal Measurements. J. Phys. D: Appl. Phys. 26, 2036-2040 (1993).
    • (1993) J. Phys. D: Appl. Phys. , vol.26 , pp. 2036-2040
    • Kitis, G.1    Charalambous, S.2    Tuyn, J.W.N.3
  • 4
    • 0003304896 scopus 로고
    • Development of a Highly Sensitive LiF Thermoluminescence Dosimeter and its Applications
    • Nakajima, T., Murayama, Y., Matsuzawa, T. and Koyano, A. Development of a Highly Sensitive LiF Thermoluminescence Dosimeter and its Applications Nucl. Instrum. Methods 157, 155-162 (1978).
    • (1978) Nucl. Instrum. Methods , vol.157 , pp. 155-162
    • Nakajima, T.1    Murayama, Y.2    Matsuzawa, T.3    Koyano, A.4
  • 5
    • 0022586754 scopus 로고
    • Newly Developed Highly Sensitive LiF:Mg,Cu,P TL Chips with High Signal-to-noise Ratio
    • Wang, S., Chen, G., Wu, F., Li, Y., Zha, Z. and Zhu, J. Newly Developed Highly Sensitive LiF:Mg,Cu,P TL Chips with High Signal-to-noise Ratio. Radiat. Prot. Dosim. 14(3), 223 (1986).
    • (1986) Radiat. Prot. Dosim. , vol.14 , Issue.3 , pp. 223
    • Wang, S.1    Chen, G.2    Wu, F.3    Li, Y.4    Zha, Z.5    Zhu, J.6
  • 6
    • 0025130068 scopus 로고
    • Dosimetric Characteristics of LiF:Mg,Cu,P, TL Phosphor Prepared at ININ, Mexico
    • Azorin, J., Gutierrez, A., Niewiadomski, T. and Gonzalez, P. Dosimetric Characteristics of LiF:Mg,Cu,P, TL Phosphor Prepared at ININ, Mexico. Radiat. Prot. Dosim. 33, 283-286 (1990).
    • (1990) Radiat. Prot. Dosim. , vol.33 , pp. 283-286
    • Azorin, J.1    Gutierrez, A.2    Niewiadomski, T.3    Gonzalez, P.4
  • 7
    • 0027240269 scopus 로고
    • Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material
    • Zha, Z., Wang, S., Shen, W., Zhu, J. and Cai, G. Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material. Radiat. Prot. Dosim. 47(1-4), 111-118 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , Issue.1-4 , pp. 111-118
    • Zha, Z.1    Wang, S.2    Shen, W.3    Zhu, J.4    Cai, G.5
  • 8
    • 0024680033 scopus 로고
    • The Influence of Non-emission Competitive Centres (NECC) on the Gamma Ray Dose Response of LiF-TLD
    • Cai, G. G. The Influence of Non-emission Competitive Centres (NECC) on the Gamma Ray Dose Response of LiF-TLD. J. Phys. D: Appl. Phys. 22, 812-816 (1989).
    • (1989) J. Phys. D: Appl. Phys. , vol.22 , pp. 812-816
    • Cai, G.G.1
  • 9
    • 0026260710 scopus 로고
    • LiF:Mg,Cu,P TL Detectors with Adjustable Energy Response
    • Wang, S. T. and Cai, G. G. LiF:Mg,Cu,P TL Detectors with Adjustable Energy Response. J. Phys. D: Appl. Phys. 24, 2072-2075 (1991).
    • (1991) J. Phys. D: Appl. Phys. , vol.24 , pp. 2072-2075
    • Wang, S.T.1    Cai, G.G.2
  • 10
    • 0343026023 scopus 로고
    • The Influence of Grain Size of LiF:Mg,Cu,P TL Material on Photon Energy Response and Dose Response
    • Cai, G. The Influence of Grain Size of LiF:Mg,Cu,P TL Material on Photon Energy Response and Dose Response. J. Phys D: Appl. Phys. 28, 1259 (1995).
    • (1995) J. Phys D: Appl. Phys. , vol.28 , pp. 1259
    • Cai, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.