메뉴 건너뛰기




Volumn 17, Issue 10, 1996, Pages 623-628

Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOCOMPATIBILITY; CLINICAL ARTICLE; FRACTURE FIXATION; HALLUX VALGUS; HUMAN; INTRAMEDULLARY NAILING; KIRSCHNER WIRE; OSTEOTOMY; PATIENT SATISFACTION; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 0029834385     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.1177/107110079601701007     Document Type: Article
Times cited : (45)

References (26)
  • 1
    • 0025971712 scopus 로고
    • Absorbable implants for the fixation of fractures
    • Bostman, O.M.: Absorbable implants for the fixation of fractures. J. Bone Joint Surg., 73A:148-153, 1991.
    • (1991) J. Bone Joint Surg. , vol.73 A , pp. 148-153
    • Bostman, O.M.1
  • 2
    • 0025784686 scopus 로고
    • Osteolytic changes accompanying degradation of absorbable fracture fixation implants
    • Bostman, O.M.: Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J. Bone Joint Surg., 73B:679-682, 1991.
    • (1991) J. Bone Joint Surg. , vol.73 B , pp. 679-682
    • Bostman, O.M.1
  • 3
    • 0025334647 scopus 로고
    • Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Bostman, O., Hitvensalo, E., Makinen, J., and Rokkanen, P.: Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers. J. Bone Joint Surg., 72B:592-596, 1990.
    • (1990) J. Bone Joint Surg. , vol.72 B , pp. 592-596
    • Bostman, O.1    Hitvensalo, E.2    Makinen, J.3    Rokkanen, P.4
  • 5
    • 0026583096 scopus 로고
    • Foreign body reactions to polyglycolide screws: Observations in 24/216 malleolar fracture cases
    • Bostman, O., Partio, E., Hirvensalo, E., and Rokkanen, P.: Foreign body reactions to polyglycolide screws: observations in 24/216 malleolar fracture cases. Acta Orthop. Scand., 63:173-176, 1992.
    • (1992) Acta Orthop. Scand. , vol.63 , pp. 173-176
    • Bostman, O.1    Partio, E.2    Hirvensalo, E.3    Rokkanen, P.4
  • 7
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Bucholz, R., Henry, S., and Henley, M.: Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J. Bone Joint Surg., 76A:319-324, 1994.
    • (1994) J. Bone Joint Surg. , vol.76 A , pp. 319-324
    • Bucholz, R.1    Henry, S.2    Henley, M.3
  • 8
    • 0026473093 scopus 로고
    • Biodegradable rods versus Kirschner wire fixation of wrist fractures: A randomised triat
    • Casteleyn, P.P., Handelberg, F., and Haentjens, P.: Biodegradable rods versus Kirschner wire fixation of wrist fractures: a randomised triat. J. Bone Joint Surg., 74B:858-861, 1992.
    • (1992) J. Bone Joint Surg. , vol.74 B , pp. 858-861
    • Casteleyn, P.P.1    Handelberg, F.2    Haentjens, P.3
  • 9
    • 0026760266 scopus 로고
    • Biodegradable fixation of ankle fractures: Complications in a prospective study of 25 cases
    • Frokjaer, J., and Moller, B.N.: Biodegradable fixation of ankle fractures: complications in a prospective study of 25 cases. Acta Orthop. Scand., 63:434-436, 1992.
    • (1992) Acta Orthop. Scand. , vol.63 , pp. 434-436
    • Frokjaer, J.1    Moller, B.N.2
  • 10
    • 0026847648 scopus 로고
    • Effectiveness of absorbable fixation devices in Austin bunionectomies
    • Gerbert, J.: Effectiveness of absorbable fixation devices in Austin bunionectomies. J. Am. Podiatr. Med. Assoc., 82:189-195, 1992.
    • (1992) J. Am. Podiatr. Med. Assoc. , vol.82 , pp. 189-195
    • Gerbert, J.1
  • 11
    • 0025469325 scopus 로고
    • Contamination and infection rate of percutaneous Kirschner wires in foot surgery
    • Halpern, F., Trepal, M., and Hodge, W.: Contamination and infection rate of percutaneous Kirschner wires in foot surgery. J. Am. Podiatr. Med. Assoc., 80:433-437, 1990.
    • (1990) J. Am. Podiatr. Med. Assoc. , vol.80 , pp. 433-437
    • Halpern, F.1    Trepal, M.2    Hodge, W.3
  • 12
    • 76949115995 scopus 로고
    • Observations on hallux valgus
    • Hardy, R., and Clapham, J.: Observations on hallux valgus. J. Bone Joint Surg., 33B:376-391, 1951.
    • (1951) J. Bone Joint Surg. , vol.33 B , pp. 376-391
    • Hardy, R.1    Clapham, J.2
  • 13
    • 0021810873 scopus 로고
    • Chevron osteotomy: Analysis of factors in patients' dissatisfaction
    • Hattrup, S.J., and Johnson, K.A.: Chevron osteotomy: analysis of factors in patients' dissatisfaction. Foot Ankle, 5:327-332, 1985.
    • (1985) Foot Ankle , vol.5 , pp. 327-332
    • Hattrup, S.J.1    Johnson, K.A.2
  • 15
    • 0026001985 scopus 로고
    • Biodegradable pin fixation of elbow fractures in children: A randomised trial
    • Hope, P.G., Williamson, D.M., Coates, C.J., and Cole, W.G.: Biodegradable pin fixation of elbow fractures in children: a randomised trial. J. Bone Joint Surg., 73B:965-968, 1991.
    • (1991) J. Bone Joint Surg. , vol.73 B , pp. 965-968
    • Hope, P.G.1    Williamson, D.M.2    Coates, C.J.3    Cole, W.G.4
  • 16
    • 0021878079 scopus 로고
    • Roentgenographic and mathematical analysis of first metatarsal osteotomies for metatarsus primus varus: A comparative study
    • Jahss, M., Troy, A., and Kummer, F.: Roentgenographic and mathematical analysis of first metatarsal osteotomies for metatarsus primus varus: a comparative study. Foot Ankle, 5:280-321, 1985.
    • (1985) Foot Ankle , vol.5 , pp. 280-321
    • Jahss, M.1    Troy, A.2    Kummer, F.3
  • 19
    • 0026764038 scopus 로고
    • Absorbable intramedullary implants for hand fractures: Animal experiments and clinical trial
    • Kumta, S.M., Spinner, R., and Leung, P.C.: Absorbable intramedullary implants for hand fractures: animal experiments and clinical trial. J. Bone Joint Surg., 74:563-566, 1992.
    • (1992) J. Bone Joint Surg. , vol.74 , pp. 563-566
    • Kumta, S.M.1    Spinner, R.2    Leung, P.C.3
  • 20
    • 0027934156 scopus 로고
    • Risk of complications of first metatarsal head osteotomies with biodegradable pin fixation: Biofix versus Orthosorb
    • Lavery, L.A., Peterson, J.D., Pollack, R., and Higgins, K.R.: Risk of complications of first metatarsal head osteotomies with biodegradable pin fixation: Biofix versus Orthosorb. J. Foot Ankle Surg., 33:334-340, 1994.
    • (1994) J. Foot Ankle Surg. , vol.33 , pp. 334-340
    • Lavery, L.A.1    Peterson, J.D.2    Pollack, R.3    Higgins, K.R.4
  • 21
    • 0019442352 scopus 로고
    • Modified chevron osteotomy of the first metatarsal
    • Lewis, R.J., and Feffer, H.L.: Modified chevron osteotomy of the first metatarsal. Clin. Orthop., 157:105-109, 1981.
    • (1981) Clin. Orthop. , vol.157 , pp. 105-109
    • Lewis, R.J.1    Feffer, H.L.2
  • 22
    • 0019416518 scopus 로고
    • Hallux valgus: Etiology, anatomy, treatment and surgical considerations
    • Mann, R.A., and Coughlin, M.J.: Hallux valgus: etiology, anatomy, treatment and surgical considerations. Clin. Orthop., 157: 31-41, 1981.
    • (1981) Clin. Orthop. , vol.157 , pp. 31-41
    • Mann, R.A.1    Coughlin, M.J.2
  • 24
    • 0026458592 scopus 로고
    • Absorbable pins of self reinforced poly-L-lactic acid for fixation of fractures and osteotomies
    • Pihlajamaki, H., Bostman, O., Hirvensalo, E., Tormala, P., and Rokkanen, P.: Absorbable pins of self reinforced poly-L-lactic acid for fixation of fractures and osteotomies. J. Bone Joint Surg., 74:853-857, 1992.
    • (1992) J. Bone Joint Surg. , vol.74 , pp. 853-857
    • Pihlajamaki, H.1    Bostman, O.2    Hirvensalo, E.3    Tormala, P.4    Rokkanen, P.5
  • 25
    • 0025861086 scopus 로고
    • Absorbable materials in orthopaedic surgery
    • Rokkanen, P.U.: Absorbable materials in orthopaedic surgery. Ann. Med., 23:109-115, 1991.
    • (1991) Ann. Med. , vol.23 , pp. 109-115
    • Rokkanen, P.U.1
  • 26
    • 0029061052 scopus 로고
    • Fixation of the chevron osteotomy utilizing absorbable polydioxanon pins
    • Small, H.N., Braly, W.G., and Tuilos, H.S.: Fixation of the chevron osteotomy utilizing absorbable polydioxanon pins. Foot Ankle Int., 16:346-350, 1995.
    • (1995) Foot Ankle Int. , vol.16 , pp. 346-350
    • Small, H.N.1    Braly, W.G.2    Tuilos, H.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.