-
1
-
-
0023577624
-
Die biologische leistung der hydroxylapatitkeramik-beschichtung auf dem femurschaft einer titanendoprothese-erste histologische auswertung eines humanexplantats
-
Osborn JF: Die biologische leistung der hydroxylapatitkeramik-beschichtung auf dem femurschaft einer titanendoprothese-erste histologische auswertung eines humanexplantats. Biomed Tech (Berlin) 32:177, 1987
-
(1987)
Biomed Tech (Berlin)
, vol.32
, pp. 177
-
-
Osborn, J.F.1
-
2
-
-
0023688524
-
Hydroxyapatite-coated titanium for orthopaedic implant applications
-
Cook SD, Thomas KA, Kay JF, Jarcho M: Hydroxyapatite-coated titanium for orthopaedic implant applications. Clin Orthop 232:225, 1988
-
(1988)
Clin Orthop
, vol.232
, pp. 225
-
-
Cook, S.D.1
Thomas, K.A.2
Kay, J.F.3
Jarcho, M.4
-
3
-
-
0023879781
-
Hydroxyapatite-coated porous titanium for use as an orthopaedic biologic attachment system
-
Cook SD, Thomas KA, Kay JF, Jarcho M: Hydroxyapatite-coated porous titanium for use as an orthopaedic biologic attachment system. Clin Orthop 230: 303, 1988
-
(1988)
Clin Orthop
, vol.230
, pp. 303
-
-
Cook, S.D.1
Thomas, K.A.2
Kay, J.F.3
Jarcho, M.4
-
4
-
-
0023499767
-
Chemical implant fixation using hydroxyl-apatite coatings: The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates
-
Geesink RGT, de Groot K, Klein CPAT: Chemical implant fixation using hydroxyl-apatite coatings: the development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop 225:147, 1987
-
(1987)
Clin Orthop
, vol.225
, pp. 147
-
-
Geesink, R.G.T.1
De Groot, K.2
Klein, C.P.A.T.3
-
6
-
-
0025860447
-
Bonding of hydroxyapatite-coated femoral prostheses: Histopathology of specimens from four cases
-
Hardy DCR, Frayssinet P, Guilhem A et al: Bonding of hydroxyapatite-coated femoral prostheses: histopathology of specimens from four cases. J Bone Joint Surg 73B:732, 1991
-
(1991)
J Bone Joint Surg
, vol.73 B
, pp. 732
-
-
Hardy, D.C.R.1
Frayssinet, P.2
Guilhem, A.3
-
7
-
-
0026352034
-
Hydroxyapatite-coated femoral stems: Histological analysis of components retrieved at autopsy
-
Bauer TW, Geesink RGT, Zimmerman R, McMahon JT: Hydroxyapatite-coated femoral stems: Histological analysis of components retrieved at autopsy. J Bone Joint Surg 73A:1439, 1991
-
(1991)
J Bone Joint Surg
, vol.73 A
, pp. 1439
-
-
Bauer, T.W.1
Geesink, R.G.T.2
Zimmerman, R.3
McMahon, J.T.4
-
8
-
-
0025898856
-
Fixation of hip prosthesis by hydroxyapatite ceramic coatings
-
Furlong RJ, Osborn JF: Fixation of hip prosthesis by hydroxyapatite ceramic coatings. J Bone Joint Surg 73B:741, 1991
-
(1991)
J Bone Joint Surg
, vol.73 B
, pp. 741
-
-
Furlong, R.J.1
Osborn, J.F.2
-
9
-
-
0027474762
-
Hydroxyapatite coating converts fibrous tissue to bone around loaded implants
-
Søballe K, Hansen ES, Rasmussen BH, Bünger C: Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg 75B:270, 1993
-
(1993)
J Bone Joint Surg
, vol.75 B
, pp. 270
-
-
Søballe, K.1
Hansen, E.S.2
Rasmussen, B.H.3
Bünger, C.4
-
10
-
-
0026323228
-
Gap healing enhanced by hydroxyapatite coating in dogs
-
Søballe K, Hansen ES, Rasmussen BH et al: Gap healing enhanced by hydroxyapatite coating in dogs. Clin Orthop 272:300, 1991
-
(1991)
Clin Orthop
, vol.272
, pp. 300
-
-
Søballe, K.1
Hansen, E.S.2
Rasmussen, B.H.3
-
11
-
-
0026832935
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
-
Søballe K, Hansen ES, Rasmussen BH et al: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 10:285, 1992
-
(1992)
J Orthop Res
, vol.10
, pp. 285
-
-
Søballe, K.1
Hansen, E.S.2
Rasmussen, B.H.3
-
12
-
-
0025642527
-
The various stress patterns of press-fit, ingrown, and cemented femoral stems
-
Huiskes R: The various stress patterns of press-fit, ingrown, and cemented femoral stems. Clin Orthop 261:27, 1990
-
(1990)
Clin Orthop
, vol.261
, pp. 27
-
-
Huiskes, R.1
-
14
-
-
0023777583
-
The influence of stem size and extent of porous coating in femoral bone resorption after primary cementless hip arthroplasty
-
Engh CA, Bobyn JD: The influence of stem size and extent of porous coating in femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7, 1988
-
(1988)
Clin Orthop
, vol.231
, pp. 7
-
-
Engh, C.A.1
Bobyn, J.D.2
-
15
-
-
0023240947
-
Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results
-
Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg 69B:45, 1987
-
(1987)
J Bone Joint Surg
, vol.69 B
, pp. 45
-
-
Engh, C.A.1
Bobyn, J.D.2
Glassman, A.H.3
-
16
-
-
0026519501
-
Producing and avoiding stress shielding: Laboratory and clinical observations of noncemented total hip arthroplasty
-
Bobyn JD, Mortimer ES, Glassman AH et al: Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79, 1992
-
(1992)
Clin Orthop
, vol.274
, pp. 79
-
-
Bobyn, J.D.1
Mortimer, E.S.2
Glassman, A.H.3
-
17
-
-
0025608937
-
Hydroxyapatite-coated total hip prostheses: Two-year clinical and roentgenographic results of 100 cases
-
Geesink RGT: Hydroxyapatite-coated total hip prostheses: two-year clinical and roentgenographic results of 100 cases. Clin Orthop 261:39, 1990
-
(1990)
Clin Orthop
, vol.261
, pp. 39
-
-
Geesink, R.G.T.1
-
18
-
-
0026472259
-
Early results with the hydroxyapatite-coated porous LSF total hip system
-
Cook SD, Enis J, Armstrong D, Lisecki E: Early results with the hydroxyapatite-coated porous LSF total hip system. Dent Clin North Am 36:247, 1992
-
(1992)
Dent Clin North Am
, vol.36
, pp. 247
-
-
Cook, S.D.1
Enis, J.2
Armstrong, D.3
Lisecki, E.4
-
19
-
-
0026473504
-
Clinical and radiographic experience with a hydroxyapatite-coated titanium plasma-sprayed porous implant
-
Vaughn BK, Lombardi AV, Mallory TH: Clinical and radiographic experience with a hydroxyapatite-coated titanium plasma-sprayed porous implant. Dent Clin North Am 36:263, 1992
-
(1992)
Dent Clin North Am
, vol.36
, pp. 263
-
-
Vaughn, B.K.1
Lombardi, A.V.2
Mallory, T.H.3
-
20
-
-
0026442089
-
Hydroxylapatite-coated hip implants: Multicenter three-year clinical and roentgenographic results
-
D'Antonio JA, Capello WN, Jaffe WL: Hydroxylapatite-coated hip implants: multicenter three-year clinical and roentgenographic results. Clin Orthop 285:102, 1992
-
(1992)
Clin Orthop
, vol.285
, pp. 102
-
-
D'Antonio, J.A.1
Capello, W.N.2
Jaffe, W.L.3
|