Volumn 85, Issue 11, 1996, Pages 1351-1353

Intravenous immune globulin in neonatal immune hemolytic disease: Does it reduce hemolysis?

Author keywords

ABO incompatibility; Carboxyhemoglobin; Coombs' positive hemolytic anemia; Hemolysis; IVIG; Neonatal immune hemolytic disease; Neonatal jaundice

Indexed keywords

CARBOXYHEMOGLOBIN; IMMUNOGLOBULIN;

EID: 0029829350     PISSN: 08035253     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1651-2227.1996.tb13924.x     Document Type: Article
Times cited : (24)

References (12)
  • 1
    • 0026036227 scopus 로고
    • High dose intravenous gamma globulin therapy for neonatal immune haemolytic jaundice due to blood group incompatibility
    • Sato K, Hara T, Kondo T, Iwao H, Honda S, Ueda K. High dose intravenous gamma globulin therapy for neonatal immune haemolytic jaundice due to blood group incompatibility. Acta Paediatr Scand 1991;80:163-6
    • (1991) Acta Paediatr Scand , vol.80 , pp. 163-166
    • Sato, K.1    Hara, T.2    Kondo, T.3    Iwao, H.4    Honda, S.5    Ueda, K.6
  • 3
    • 0027248331 scopus 로고
    • Intravenous immunoglobulin therapy in neonatal immune hemolytic jaundice
    • Ergaz Z and Arad I. Intravenous immunoglobulin therapy in neonatal immune hemolytic jaundice. J Perinat Med 1993;21: 183-7
    • (1993) J Perinat Med , vol.21 , pp. 183-187
    • Ergaz, Z.1    Arad, I.2
  • 4
    • 0020453362 scopus 로고
    • Paired determinations of blood carboxyhemoglobin concentrations and carbon monoxide excretion rate in term and preterm infants
    • Ostrander CR, Cohen RS, Hopper AO, Cowan BE, Stevens GB, Stevenson DK. Paired determinations of blood carboxyhemoglobin concentrations and carbon monoxide excretion rate in term and preterm infants. J Lab Clin Med 1982;100:745-55.
    • (1982) J Lab Clin Med , vol.100 , pp. 745-755
    • Ostrander, C.R.1    Cohen, R.S.2    Hopper, A.O.3    Cowan, B.E.4    Stevens, G.B.5    Stevenson, D.K.6
  • 6
    • 0023204855 scopus 로고
    • Analysis for carboxy hemoglobin by gas chromatography and multicomponent spectrophotometry compared
    • Vreman HJ, Stevenson DK and Zwart A. Analysis for carboxy hemoglobin by gas chromatography and multicomponent spectrophotometry compared. Clin Chem 1987;33:694-7
    • (1987) Clin Chem , vol.33 , pp. 694-697
    • Vreman, H.J.1    Stevenson, D.K.2    Zwart, A.3
  • 7
    • 0018751299 scopus 로고
    • ADCC (K cell) lysis of human erythrocytes sensitized with Rhesus alloantibodies. II. Investigation into the mechanism of lysis
    • Urbaníak SJ. ADCC (K cell) lysis of human erythrocytes sensitized with Rhesus alloantibodies. II. Investigation into the mechanism of lysis. Br. J Haematol 1979;42:315-28
    • (1979) Br. J Haematol , vol.42 , pp. 315-328
    • Urbaníak, S.J.1
  • 10
    • 0028896481 scopus 로고
    • Glucose-6-phosphate dehydrogenase deficiency and carboxyhemoglobin concentrations associated with bilirubin related morbidity and death in Nigerian infants
    • Slusher T, Vreman HJ, McLaren DW, Lewison L, Brown A, Stevenson DK. Glucose-6-phosphate dehydrogenase deficiency and carboxyhemoglobin concentrations associated with bilirubin related morbidity and death in Nigerian infants. J Pediatr 1995; 126:102-8
    • (1995) J Pediatr , vol.126 , pp. 102-108
    • Slusher, T.1    Vreman, H.J.2    McLaren, D.W.3    Lewison, L.4    Brown, A.5    Stevenson, D.K.6
  • 11
    • 0029124896 scopus 로고
    • Carboxyhemoglobin levels in neonatal immune hemolytic jaundice treated with intravenous gamma globulin
    • Ergaz Z, Gross D, Bar-Oz B, Peleg O and Arad I. Carboxyhemoglobin levels in neonatal immune hemolytic jaundice treated with intravenous gamma globulin. Vox Sang 1995;69:95-9
    • (1995) Vox Sang , vol.69 , pp. 95-99
    • Ergaz, Z.1    Gross, D.2    Bar-Oz, B.3    Peleg, O.4    Arad, I.5
  • 12
    • 0027255047 scopus 로고
    • Measurement of carboxyhemoglobin and total hemoglobin by live specialized spectrophotometers (CO-oximeters) in comparison with reference methods
    • Mahoney JJ, Vreman HJ, Stevenson DK and Van Kessel AL. Measurement of carboxyhemoglobin and total hemoglobin by live specialized spectrophotometers (CO-oximeters) in comparison with reference methods. Clin Chem 1993;1693-1700
    • (1993) Clin Chem , pp. 1693-1700
    • Mahoney, J.J.1    Vreman, H.J.2    Stevenson, D.K.3    Van Kessel, A.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.