메뉴 건너뛰기




Volumn 51, Issue 10, 1996, Pages 912-915

A comparison of the forces exerted during laryngoscopy. The Macintosh versus the McCoy blade

Author keywords

Equipment, laryngoscope, Macintosh, McCoy; Larynx, laryngoscopy; Measurement techniques, strain gauge

Indexed keywords

ADULT; AGED; ARTICLE; BODY HEIGHT; BODY MASS; BODY WEIGHT; CLINICAL ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EQUIPMENT; FEMALE; FORCE; HUMAN; LARYNGOSCOPY; MALE; STRESS; TIME;

EID: 0029828334     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.1996.tb14955.x     Document Type: Article
Times cited : (40)

References (26)
  • 1
    • 0001740168 scopus 로고
    • Endotracheal intubation: Effects on blood pressure and pulse rate
    • WYCOFF CC. Endotracheal intubation: effects on blood pressure and pulse rate. Anesthesiology 1960; 21: 153-8.
    • (1960) Anesthesiology , vol.21 , pp. 153-158
    • Wycoff, C.C.1
  • 2
    • 0017725120 scopus 로고
    • Circulatory changes during direct laryngoscopy and tracheal intubation: Influence of duration of laryngoscopy with and without prior lidocaine
    • STOELTING RK. Circulatory changes during direct laryngoscopy and tracheal intubation: influence of duration of laryngoscopy with and without prior lidocaine. Anesthesiology 1977; 47: 381-4.
    • (1977) Anesthesiology , vol.47 , pp. 381-384
    • Stoelting, R.K.1
  • 3
    • 0023150275 scopus 로고
    • Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation
    • SHRIBMAN AJ, SMITH G, ACHOLA KJ. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation. British Journal of Anaesthesia 1987; 59: 295-9.
    • (1987) British Journal of Anaesthesia , vol.59 , pp. 295-299
    • Shribman, A.J.1    Smith, G.2    Achola, K.J.3
  • 5
    • 7344222246 scopus 로고
    • Measurement of the pressure of the laryngoscope during tracheal intubation
    • SCHECK PAE. Measurement of the pressure of the laryngoscope during tracheal intubation. Anaesthesia 1982; 37: 370.
    • (1982) Anaesthesia , vol.37 , pp. 370
    • Scheck, P.A.E.1
  • 7
  • 8
    • 0028415513 scopus 로고
    • The McCoy levering laryngoscope blade
    • WARD M. The McCoy levering laryngoscope blade. Anaesthesia 1994; 49: 357-8.
    • (1994) Anaesthesia , vol.49 , pp. 357-358
    • Ward, M.1
  • 9
    • 0028417634 scopus 로고
    • The McCoy levering laryngoscope blade
    • FARLING PA. The McCoy levering laryngoscope blade. Anaesthesia 1994; 49: 358.
    • (1994) Anaesthesia , vol.49 , pp. 358
    • Farling, P.A.1
  • 10
    • 0028412216 scopus 로고
    • The McCoy levering laryngoscope blade
    • JOHNSTON HML, RAO U. The McCoy levering laryngoscope blade. Anaesthesia 1994; 49: 358.
    • (1994) Anaesthesia , vol.49 , pp. 358
    • Johnston, H.M.L.1    Rao, U.2
  • 11
    • 0029319314 scopus 로고
    • Another trachea intubated with the McCoy laryngoscope
    • CHADWICK IS, MCCLUSKEY A. Another trachea intubated with the McCoy laryngoscope. Anaesthesia 1995; 50: 571.
    • (1995) Anaesthesia , vol.50 , pp. 571
    • Chadwick, I.S.1    Mccluskey, A.2
  • 12
    • 0029686914 scopus 로고    scopus 로고
    • An evaluation of the levering laryngoscope
    • TUCKEY JP, COOK TM, RENDER CA. An evaluation of the levering laryngoscope. Anaesthesia 1996; 51: 71-3.
    • (1996) Anaesthesia , vol.51 , pp. 71-73
    • Tuckey, J.P.1    Cook, T.M.2    Render, C.A.3
  • 13
    • 0029925208 scopus 로고    scopus 로고
    • The use of the McCoy laryngoscope in patients with simulated cervical spine injuries
    • LAURENT SC, DE MELO AE, ALEXANDER-WILLIAMS JM. The use of the McCoy laryngoscope in patients with simulated cervical spine injuries. Anaesthesia 1996; 51: 74-5.
    • (1996) Anaesthesia , vol.51 , pp. 74-75
    • Laurent, S.C.1    De Melo, A.E.2    Alexander-Williams, J.M.3
  • 14
    • 0028874711 scopus 로고
    • A comparison of the stress response to laryngoscopy. The Macintosh versus the McCoy blade
    • MCCOY EP, MIRAKHUR RK, MCCLOSKEY BV. A comparison of the stress response to laryngoscopy. The Macintosh versus the McCoy blade. Anaesthesia 1995; 50: 943-6.
    • (1995) Anaesthesia , vol.50 , pp. 943-946
    • Mccoy, E.P.1    Mirakhur, R.K.2    Mccloskey, B.V.3
  • 15
    • 0028908308 scopus 로고
    • A New device for measuring and recording the forces applied during laryngoscopy
    • MCCOY EP, AUSTIN BA, MIRAKHUR RK, WONG WC. A New device for measuring and recording the forces applied during laryngoscopy. Anaesthesia 1995; 50: 139-43.
    • (1995) Anaesthesia , vol.50 , pp. 139-143
    • Mccoy, E.P.1    Austin, B.A.2    Mirakhur, R.K.3    Wong, W.C.4
  • 16
    • 0014977656 scopus 로고
    • Unusual problems in airway management II. the influence of the temporo-mandibular joint, the mandible and associated structures on endotracheal intubation
    • BLOCK C, BRECHNER VL. Unusual problems in airway management II. The influence of the temporo-mandibular joint, the mandible and associated structures on endotracheal intubation. Anesthesia and Analgesia 1971; 50: 114-23.
    • (1971) Anesthesia and Analgesia , vol.50 , pp. 114-123
    • Block, C.1    Brechner, V.L.2
  • 18
    • 0023756066 scopus 로고
    • Criteria for estimating likelihood of difficulty of endotracheal intubation with the Macintosh laryngoscope
    • BELLHOUSE CP, DORÉ C. Criteria for estimating likelihood of difficulty of endotracheal intubation with the Macintosh laryngoscope. Anaesthesia and Intensive Care 1988; 16: 329-37.
    • (1988) Anaesthesia and Intensive Care , vol.16 , pp. 329-337
    • Bellhouse, C.P.1    Doré, C.2
  • 19
    • 0026750659 scopus 로고
    • Forces applied during laryngoscopy and their relationship with patient characteristics
    • BUCX MJL, VAN GEEL RTM, SCHECK PAE, STIJNEN T, ERDMANN W. Forces applied during laryngoscopy and their relationship with patient characteristics. Anaesthesia 1992; 47: 601-3.
    • (1992) Anaesthesia , vol.47 , pp. 601-603
    • Bucx, M.J.L.1    Van Geel, R.T.M.2    Scheck, P.A.E.3    Stijnen, T.4    Erdmann, W.5
  • 20
    • 0028951626 scopus 로고
    • Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope
    • BUCX MJL, VAN GEEL RTM, WEGENER JT, ROBERS C, STIJNEN T. Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope. Canadian Journal of Anaesthesia 1995; 42: 144-9.
    • (1995) Canadian Journal of Anaesthesia , vol.42 , pp. 144-149
    • Bucx, M.J.L.1    Van Geel, R.T.M.2    Wegener, J.T.3    Robers, C.4    Stijnen, T.5
  • 22
    • 0000783764 scopus 로고
    • Endotracheal intubation
    • Miller RD, ed. New York: Churchill Livingstone
    • STOELTING RK. Endotracheal intubation. In: Miller RD, ed. Anesthesia. New York: Churchill Livingstone, 1986; 523-52.
    • (1986) Anesthesia , pp. 523-552
    • Stoelting, R.K.1
  • 23
    • 0141702925 scopus 로고
    • Conventional (laryngoscopic) orotracheal and nasotracheal intubation
    • Benumof JL, ed. Philadelphia: Lippincott Company
    • BENUMOF JL. Conventional (laryngoscopic) orotracheal and nasotracheal intubation. In: Benumof JL, ed. Clinical procedures in anesthesia and intensive care. Philadelphia: Lippincott Company, 1992: 115-48.
    • (1992) Clinical Procedures in Anesthesia and Intensive Care , pp. 115-148
    • Benumof, J.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.