메뉴 건너뛰기




Volumn 34, Issue 10, 1996, Pages 817-822

Some Analytical Considerations on the Measurement of Prostate-Specific Antigen

Author keywords

[No Author keywords available]

Indexed keywords

PROSTATE SPECIFIC ANTIGEN;

EID: 0029826247     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm.1996.34.10.817     Document Type: Article
Times cited : (14)

References (16)
  • 2
    • 0021045350 scopus 로고
    • A new biomedical procedure for testing the equality of measurements from two different analytical methods
    • Passing H, Bablok W. A new biomedical procedure for testing the equality of measurements from two different analytical methods. J Clin Chem Clin Biochem 1983; 21: 709-720.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0030021476 scopus 로고    scopus 로고
    • Analysis of method comparison studies
    • Hollis S. Analysis of method comparison studies. Ann Clin Biochem 1996; 33: 1-4.
    • (1996) Ann Clin Biochem , vol.33 , pp. 1-4
    • Hollis, S.1
  • 5
    • 0027717357 scopus 로고
    • Multiple forms of prostate-specific antigen in serum: differences in immunorecognition by monoclonal and polyclonal assays
    • Zhou AM, Tewari PC, Bluestein BI, Coldwell GW. Multiple forms of prostate-specific antigen in serum: differences in immunorecognition by monoclonal and polyclonal assays. Clin Chem 1993; 39: 2483-2491.
    • (1993) Clin Chem , vol.39 , pp. 2483-2491
    • Zhou, A.M.1    Tewari, P.C.2    Bluestein, B.I.3    Coldwell, G.W.4
  • 6
    • 0029048111 scopus 로고
    • Assay variability in serum prostate-specific antigen determination
    • Brawer MK, Daum P, Petteway, Wener MH. Assay variability in serum prostate-specific antigen determination. The Prostate 1995; 26: 1-6.
    • (1995) The Prostate , vol.26 , pp. 1-6
    • Brawer, M.K.1    Daum, P.2    Petteway3    Wener, M.H.4
  • 7
    • 85025251713 scopus 로고
    • An evaluation of four commercially available immunoassays for measuring prostate-specific antigen
    • 1994 Sept 18-22; Groningen (The Netherlands). Tumor Biol
    • Wright GL, Fritsche HA. An evaluation of four commercially available immunoassays for measuring prostate-specific antigen. Presented at XXII Meeting of International Society for Oncodevelopmental Biology and Medicine; 1994 Sept 18-22; Groningen (The Netherlands). Tumor Biol 1995; 16: 317.
    • (1995) Presented at XXII Meeting of International Society for Oncodevelopmental Biology and Medicine , vol.16 , pp. 317
    • Wright, G.L.1    Fritsche, H.A.2
  • 8
    • 0027210935 scopus 로고
    • Growing use of nonisotopic CA 19-9 immunoassays increases betweenlaboratory variability
    • Zucchelli GC, Pilo A, Chiesa MR. Growing use of nonisotopic CA 19-9 immunoassays increases betweenlaboratory variability. Clin Chem 1993; 39: 909-911.
    • (1993) Clin Chem , vol.39 , pp. 909-911
    • Zucchelli, G.C.1    Pilo, A.2    Chiesa, M.R.3
  • 9
    • 0026672141 scopus 로고
    • Assays for serodiagnosis of prostate cancer
    • Hall M, Johnson JT, Carr J. Assays for serodiagnosis of prostate cancer. Lab Med 1992; 23: 607-612.
    • (1992) Lab Med , vol.23 , pp. 607-612
    • Hall, M.1    Johnson, J.T.2    Carr, J.3
  • 11
    • 0028804599 scopus 로고
    • The second Stanford conference on international standardization of prostate-specific antigen assays
    • Murphy GP. The second Stanford conference on international standardization of prostate-specific antigen assays. Cancer 1995; 75: 122-128.
    • (1995) Cancer , vol.75 , pp. 122-128
    • Murphy, G.P.1
  • 12
    • 0028884909 scopus 로고
    • Variation in measurement of prostate-specific antigen: importance of method and lot variability
    • Wener MH, Daum PR, Brawer MK. Variation in measurement of prostate-specific antigen: importance of method and lot variability. Clin Chem 1995; 41: 1730-737.
    • (1995) Clin Chem , vol.41 , pp. 1730-1737
    • Wener, M.H.1    Daum, P.R.2    Brawer, M.K.3
  • 13
    • 84910890153 scopus 로고
    • Betweenlot/betweeninstrument variations of the Abbott IMx method for prostate-specific antigen
    • Magic SE, Pennoyer JD. Betweenlot/betweeninstrument variations of the Abbott IMx method for prostate-specific antigen. Clin Chem 1992; 38: 2343.
    • (1992) Clin Chem , vol.38 , pp. 2343
    • Magic, S.E.1    Pennoyer, J.D.2
  • 14
    • 0027293359 scopus 로고
    • Analytical performance goals for measuring prostate-specific antigen
    • Fritsche HA, Babaian RJ. Analytical performance goals for measuring prostate-specific antigen. Clin Chem 1993; 39: 1525-529.
    • (1993) Clin Chem , vol.39 , pp. 1525-1529
    • Fritsche, H.A.1    Babaian, R.J.2
  • 15
    • 0027346558 scopus 로고
    • Quality control and standardization of tumour marker tests
    • Van Dalen A. Quality control and standardization of tumour marker tests. Tumor Biol 1993; 14: 131-135.
    • (1993) Tumor Biol , vol.14 , pp. 131-135
    • Van Dalen, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.