메뉴 건너뛰기




Volumn 26, Issue 12, 1996, Pages 891-893

Evaluation of image quality using 1:1 pitch and 1.5:1 pitch helical CT in children: A comparative study

Author keywords

[No Author keywords available]

Indexed keywords

IOHEXOL;

EID: 0029824943     PISSN: 03010449     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178045     Document Type: Article
Times cited : (51)

References (10)
  • 2
    • 0025855784 scopus 로고
    • Pulmonary nodule: Evaluation with spiral volumetric CT
    • Costello P, Anderson W, Blume D (1991) Pulmonary nodule: evaluation with spiral volumetric CT. Radiology 179: 875-876
    • (1991) Radiology , vol.179 , pp. 875-876
    • Costello, P.1    Anderson, W.2    Blume, D.3
  • 3
    • 0028072590 scopus 로고
    • CT of chest and abdomen in patients on mechanical pulmonary ventilators: Quality of images made at 0.6 versus 1.0 seconds
    • Posniak HV, Olson MC, Demos TC, Pierce KL, Kalbhen CL (1994) CT of chest and abdomen in patients on mechanical pulmonary ventilators: quality of images made at 0.6 versus 1.0 seconds. AJR 163: 1073-1077
    • (1994) AJR , vol.163 , pp. 1073-1077
    • Posniak, H.V.1    Olson, M.C.2    Demos, T.C.3    Pierce, K.L.4    Kalbhen, C.L.5
  • 4
    • 0027503076 scopus 로고
    • Detection of focal hepatic lesions with spiral CT: Comparison of 4- and 8-mm interscan spacing
    • Urban BA, Fishman EK, Kuhlman JE, Kawashima A, Hennessey JG, Siegelman SS (1993) Detection of focal hepatic lesions with spiral CT: comparison of 4- and 8-mm interscan spacing. AJR 160: 783-785
    • (1993) AJR , vol.160 , pp. 783-785
    • Urban, B.A.1    Fishman, E.K.2    Kuhlman, J.E.3    Kawashima, A.4    Hennessey, J.G.5    Siegelman, S.S.6
  • 5
    • 0027245609 scopus 로고
    • Pulmonary nodules: Detection with thick-section spiral CT versus conventional CT
    • Remy-Jardin M, Remy J, Giraud F Marquette CH (1993) Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187: 513-520
    • (1993) Radiology , vol.187 , pp. 513-520
    • Remy-Jardin, M.1    Remy, J.2    Giraud, F.3    Marquette, C.H.4
  • 7
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P (1990) Spiral volumetric CT with single-breath hold technique, continuous transport, and continuous scanner rotation. Radiology 176: 181-183
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 8
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A, Kalender WA, Marchal G (1992) Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 185: 29-35
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 9
    • 0026661923 scopus 로고
    • Spiral CT: Decreased spatial resolution in vivo due to broadening of section-sensitivity profile
    • Brink JA, Heiken JP, Balfe DM, Sagel SS, DiCroce J, Vannier MW (1992) Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile. Radiology 185: 469-474
    • (1992) Radiology , vol.185 , pp. 469-474
    • Brink, J.A.1    Heiken, J.P.2    Balfe, D.M.3    Sagel, S.S.4    DiCroce, J.5    Vannier, M.W.6
  • 10
    • 0007406058 scopus 로고
    • Abdomen spiral CT: Effect of interpolation algorithm, collimation and zoom on effective section thickness and noise
    • Brink JA, Vannier MW, Heiken JP, Kalender WA, Yoffie RL, Brundsen BS (1992) Abdomen spiral CT: effect of interpolation algorithm, collimation and zoom on effective section thickness and noise (abstract). Radiology 185(P): 126
    • (1992) Radiology , vol.185 P , pp. 126
    • Brink, J.A.1    Vannier, M.W.2    Heiken, J.P.3    Kalender, W.A.4    Yoffie, R.L.5    Brundsen, B.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.