메뉴 건너뛰기




Volumn 5, Issue 5, 1996, Pages 450-455

Maintenance of clear vision during laparoscopic surgery

Author keywords

Endoscopy; Laparoscopy; Technology medical instrumentation

Indexed keywords

ARTICLE; BLEEDING; CAUTERIZATION; HEATING; HUMAN; HUMIDITY; IMAGE DISPLAY; IMAGE QUALITY; LAPAROSCOPIC SURGERY; PRIORITY JOURNAL; SMOKE; SURGEON; VISION; WATER VAPOR;

EID: 0029822413     PISSN: 0961625X     EISSN: None     Source Type: Journal    
DOI: 10.3109/13645709609153708     Document Type: Article
Times cited : (25)

References (9)
  • 2
    • 0029850321 scopus 로고    scopus 로고
    • Physical conditions that influence optical clarity in a laparoscopic environment
    • Flemming E, Bessell JR, Eibl H, Buess G. Physical conditions that influence optical clarity in a laparoscopic environment. Min Invas Ther Allied Technol 1996; 5: 440-4
    • (1996) Min Invas Ther Allied Technol , vol.5 , pp. 440-444
    • Flemming, E.1    Bessell, J.R.2    Eibl, H.3    Buess, G.4
  • 4
    • 16144364764 scopus 로고
    • Pollution in medical operating theatres caused by laser-tissue interaction
    • Weber L, ed. Indoor Air International, Rothenfluh, Switzerland
    • Wöllmer W. Pollution in medical operating theatres caused by laser-tissue interaction. In: Weber L, ed. Indoor air pollution - proceedings of the international conference. Indoor Air International, Rothenfluh, Switzerland, 1994: 319-27
    • (1994) Indoor Air Pollution - Proceedings of the International Conference , pp. 319-327
    • Wöllmer, W.1
  • 5
    • 84901016322 scopus 로고
    • Development and application of a minimized sampling procedure for access of early reaction products in laser plume anaysis
    • van Gemert, ed. SPIE Bellingham, Washington
    • Wöllmer W, Mihalache DL, Franke S, Francke W. Development and application of a minimized sampling procedure for access of early reaction products in laser plume anaysis. In: van Gemert, ed. Proceedings of 'Laser interaction with soft tissue', SPIE Vol. 2077. Bellingham, Washington, 1994: 286-91
    • (1994) Proceedings of 'Laser Interaction with Soft Tissue' , vol.2077 , pp. 286-291
    • Wöllmer, W.1    Mihalache, D.L.2    Franke, S.3    Francke, W.4
  • 6
    • 0039982546 scopus 로고
    • Instrumentation and allied technology for endoscopic surgery
    • Cuschieri A, Buess G, Perissat J, ed. Berlin: Springer-Verlag
    • Melzer A, Buess G, Cuschieri A. Instrumentation and allied technology for endoscopic surgery. In: Cuschieri A, Buess G, Perissat J, ed. Operative manual of endoscopic surgery, Vol. 2. Berlin: Springer-Verlag, 1994, 1-70
    • (1994) Operative Manual of Endoscopic Surgery , vol.2 , pp. 1-70
    • Melzer, A.1    Buess, G.2    Cuschieri, A.3
  • 7
    • 0026621205 scopus 로고
    • A self-cleaning laparoscope for minimally invasive surgery
    • Gomella LG, Lofti MA, Bagley DH. A self-cleaning laparoscope for minimally invasive surgery. Min Invas Ther 1992; 1: 401-3
    • (1992) Min Invas Ther , vol.1 , pp. 401-403
    • Gomella, L.G.1    Lofti, M.A.2    Bagley, D.H.3
  • 8
    • 0029340017 scopus 로고
    • Hypothermia induced by laparoscopic insufflation: A randomized study in a pig model
    • Bessell JR, Karatassas A, Jamieson GG, Maddern GJ. Hypothermia induced by laparoscopic insufflation: a randomized study in a pig model. Surg Endosc 1995; 9: 791-5
    • (1995) Surg Endosc , vol.9 , pp. 791-795
    • Bessell, J.R.1    Karatassas, A.2    Jamieson, G.G.3    Maddern, G.J.4
  • 9
    • 0029348665 scopus 로고
    • OREST II - Ergonomic workplace and systems platform for endoscopic technologies
    • Schurr MO, Buess G. OREST II - ergonomic workplace and systems platform for endoscopic technologies. Endosc Surg Allied Technol 1995; 3: 193-8
    • (1995) Endosc Surg Allied Technol , vol.3 , pp. 193-198
    • Schurr, M.O.1    Buess, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.