메뉴 건너뛰기




Volumn 273, Issue 5280, 1996, Pages 1384-1386

Time-sensitive reversal of hyperplasia in transgenic mice expressing SV40 T antigen

Author keywords

[No Author keywords available]

Indexed keywords

VIRUS T ANTIGEN;

EID: 0029818753     PISSN: 00368075     EISSN: None     Source Type: Journal    
DOI: 10.1126/science.273.5280.1384     Document Type: Article
Times cited : (221)

References (26)
  • 2
    • 0023631608 scopus 로고
    • E. Sinn et al., Cell 49, 465 (1987).
    • (1987) Cell , vol.49 , pp. 465
    • Sinn, E.1
  • 10
    • 0023731010 scopus 로고
    • J. A. DeCaprio et al., Cell 54, 275 (1988).
    • (1988) Cell , vol.54 , pp. 275
    • DeCaprio, J.A.1
  • 17
    • 0028169994 scopus 로고
    • H Symonds et al., Cell 78, 703 (1994).
    • (1994) Cell , vol.78 , pp. 703
    • Symonds, H.1
  • 20
    • 9544231084 scopus 로고    scopus 로고
    • note
    • Salivary gland tissue was homogenized in 1% NP-40, 0.5% sodium deoxycholate, 01% SDS, phenylmethylsulfonyl fluoride (10 mg/ml), aprotinin (30 μl/ ml) (Sigma), and 100 mM sodium orthovanadate in phosphate buffered saline. Proteins (20 μg) were separated in an 8% SDS-polyacrylamide gel and transferred onto a NOVEX polyvinylidene diflouride membrane by means of a NOVEX Western Transfer Apparatus. After transfer and blocking with buffer [5% nonfat milk, 10 mM tris-HCI (pH 7.5), 100 mM NaCI, and 0.1% Tween-20] for 1 hour at room temperature, the membrane was exposed to a 1:400 dilution of mouse monoclonal antibody Pab 101 (Santa Cruz Biotechnology, Santa Cruz, CA) followed by exposure to a 1:4000 dilution of peroxidase-conjugated rabbit polyclonal antibody to mouse immunoglobulin G (Jackson Immunochemical, West Grove, PA) for 1 hour at room temperature. The proteins were visualized with the ECL protein immunoblotting protocol (Amersham).
  • 21
    • 9544228702 scopus 로고    scopus 로고
    • Slow-release tetracycline pellets (Innovative Research of America, Toledo, OH) were implanted sub-cutaneously in the shoulder region with the use of a trochar according to the manufacturer's directions. These pellets released 0.7 mg of tetracycline hydrochloride per day over a 21-day period
    • Slow-release tetracycline pellets (Innovative Research of America, Toledo, OH) were implanted sub-cutaneously in the shoulder region with the use of a trochar according to the manufacturer's directions. These pellets released 0.7 mg of tetracycline hydrochloride per day over a 21-day period.
  • 23
    • 9544220061 scopus 로고    scopus 로고
    • unpublished data. Quantative analyses on two mice revealed that approximately 40% of the ducts were hyperplaslic
    • P. A. Furth and L, Hennighausen, unpublished data. Quantative analyses on two mice revealed that approximately 40% of the ducts were hyperplaslic.
    • Furth, P.A.1    Hennighausen, L.2
  • 24
    • 9544249762 scopus 로고    scopus 로고
    • note
    • The degree of ploidy was determined on Feulgenstained paraffin sections.
  • 26
    • 9544245196 scopus 로고    scopus 로고
    • We thank G. Robinson for critical reading of the manuscript and K. Heermeier, X. Liu, K.-U. Wagner, and J. Hu for technical advice. Supported in part by a Pangborn Award from the University of Maryland Medical School (to P.A.F.)
    • We thank G. Robinson for critical reading of the manuscript and K. Heermeier, X. Liu, K.-U. Wagner, and J. Hu for technical advice. Supported in part by a Pangborn Award from the University of Maryland Medical School (to P.A.F.).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.